Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Fuse Service, Inc. 01.23.2026
Minor Construction Agreement (revised Nov. 2023) 1 MINOR CONSTRUCTION AGREEMENT BETWEEN THE TOWN OF LOS ALTOS HILLS AND FUSE SERVICE, INC. This Agreement (this “Agreement”) is made and entered into between the Town of Los Altos Hills, a General Law City (“Town”) and Fuse Service, Inc. (“Contractor”) effective as of ___1/23/2026_______ (the “Effective Date”). Town and Contractor are hereinafter collectively referred to as (the “Parties”). In consideration of their mutual covenants, the Parties hereby agree as follows: 1. Scope of Work. Contractor shall provide the following services and/or materials (“the Work”): Town Hall Emergency HVAC Project as more particularly described in the Scope of Work, attached hereto and incorporated herein as Exhibit A. In the event of a conflict or inconsistency between the text of the main body of this Agreement and Exhibit A, the text of the main body of this Agreement shall prevail. The Work shall commence on January 26, 2026, and shall be completed to the satisfaction of the Town by December 31, 2026, unless such date is extended or otherwise modified by the Town in writing. 2. Payment. Town shall pay Contractor an amount not to exceed: One Hundred Sixty Thousand Dollars ($160,000) for the full and satisfactory completion of the Work in accordance with the terms and conditions of this Agreement. The amount includes Fifteen Thousand Dollars ($15,000) in contingency fund for change orders, if any, to be approved by the Public Works Director. The calculation of payment for the Work shall be set forth as described in Exhibit A. The amount stated above is the entire compensation payable to Contractor for the Work performed hereunder, including all labor, materials, tools, and equipment furnished by Contractor. (A) Invoices. Town shall make monthly payments, based on invoices received, for Work satisfactorily performed. Town shall have thirty (30) days from the receipt of an invoice that complies with all of the requirements above to pay Contractor. (B) False Claims Act. Presenting a false or fraudulent claim for payment, including a change order, is a violation of the California False Claims Act and may result in treble damages and a fine of five thousand ($5,000) to ten thousand dollars ($10,000) per violation. (C) Retention and Final Payment. Town shall retain five percent (5%) of each payment, which shall be paid within sixty (60) days after acceptance of the services, as described in Section 11, and submittal to Town of a final invoice, if all services required have been satisfactorily performed. Contractor may substitute securities or establish an escrow in lieu of retainage, pursuant to Public Contract Code Section 22300. 3. Independent Contractor. It is understood and agreed that this Agreement is not a contract of employment and does not create an employer-employee relationship between the Town and Contractor. At all times Contractor shall be an independent contractor and Contractor is not authorized to bind the Town to any contracts or other obligations without the express written consent of the Town. 4. Indemnification. To the fullest extent permitted by law, Contractor shall indemnify, defend (with counsel acceptable to the Town), and hold harmless the Town and its elected and appointed officers, officials, employees, agents, contractors and consultants (collectively, the “Town Indemnitees”) from and against any and all liability, loss, damage, claims, expenses and costs (including, without limitation, attorneys’ fees and costs of litigation) (collectively, “Liability”) of every nature arising out of or in connection with Contractor’s performance of the Work or Contractor’s failure to comply with this Agreement, except such Liability caused by the gross negligence or willful misconduct of the Town Indemnitees. Minor Construction Agreement (revised Nov. 2023) 2 5. Excavations. In accordance with Public Contracts Code Section 714, Contractor shall promptly notify the Town in writing of discovery of any material Contractor believes may be hazardous waste as defined in Section 25117 of the Health and Safety Code or of any subsurface or latent physical conditions at the site of any unusual nature differing materially from those generally inherent in the work described in Exhibit A. Upon receipt of such communication, Town shall promptly investigate the conditions and if conditions do materially differ, shall issue a change order providing for additional time or payment of additional costs. 6. Relocation of Utilities. In the event that the completion of the services described in Exhibit A requires the removal or protection of main or trunk line public utility facilities, the Town shall be responsible for removal and protection of such public utilities pursuant to Government Code Section 4215. 7. Insurance. Prior to beginning the Work and continuing throughout the term of this Agreement, Contractor (and any subcontractors) shall, at Contractor’s (or subcontractor’s) sole cost and expense, furnish the Town with certificates of insurance evidencing that Contractor has obtained and maintains insurance in the following amounts: A. Workers’ Compensation that satisfies the minimum statutory limits. B. Commercial General Liability and Property Damage Insurance in an amount not less than TWO MILLION DOLLARS ($2,000,000) combined single limit per occurrence, FOUR MILLION DOLLARS ($4,000,000) annual aggregate, for bodily injury, property damage, products, completed operations and contractual liability coverage. The policy shall also include coverage for liability arising out of the use and operation of any Town-owned or Town-furnished equipment used or operated by the Contractor, its personnel, agents or subcontractors. C. Comprehensive automobile insurance in an amount not less than ONE MILLION DOLLARS ($1,000,000) per occurrence for bodily injury and property damage including coverage for owned and non-owned vehicles. All insurance policies shall be written on an occurrence basis and shall name the Town Indemnitees as additional insureds. The certificates shall contain a statement of obligation on the part of the carrier to notify the Town of any material change, cancellation, termination or non-renewal of the coverage at least thirty (30) days in advance of the effective date of any such material change, cancellation, termination or non-renewal. Further, if the Contractor’s insurance policy includes a self-insured retention that must be paid by a named insured as a precondition of the insurer’s liability, or which has the effect of providing that payments of the self-insured retention by others, including additional insureds or insurers do not serve to satisfy the self-insured retention, such provisions must be modified by special endorsement so as to not apply to the additional insured coverage required by this agreement so as to not prevent any of the parties to this agreement from satisfying or paying the self-insured retention required to be paid as a precondition to the insurer’s liability. Additionally, the certificates of insurance must note whether the policy does or does not include any self-insured retention and also must disclose the deductible. 8. General Warranties and Guarantee. Contractor warrants that: (A) All Work, Products and/or Services are as described in this Agreement, including any exhibits incorporated] conform to all drawings, samples, descriptions and specifications; (B) All Work, Products and/or Services delivered are new and of good merchantable quality, free from material defects of workmanship and fit for the purpose for which sold or provided; (C) Contractor has good title to all Products delivered and all Products delivered are free from liens and other encumbrances; and (D) Contractor's Work will be in strict conformity with all applicable local, state, and federal laws. For purposes of this warranty, any parts not meeting the foregoing quality shall be deemed defective. Minor Construction Agreement (revised Nov. 2023) 3 Contractor shall guarantee the Work to be free of defects in material and workmanship for a period of one (1) year following the Town’s acceptance of the Work (“Contractor’s Guarantee”), as described in Section 11. As part of Contractor’s Guarantee, Contractor agrees to make, at Contractor’s own expense, any repairs or replacements made necessary by defects in material or workmanship which become evident within the one-year guarantee period. The Contractor’s Guarantee is effective regardless of whether or not a maintenance bond is required by the Town for this Agreement. 9. Contract Bonds. 9.1 General. Before the Town executes this Agreement, the Contractor shall file with the Town surety bonds satisfactory to the Town in the amounts and for the purposes noted in this Section 9. Bonds shall be duly executed by an admitted surety insurer, authorized to issue such bonds in the State of California and secured through an authorized agent with an office in California. The Contractor shall pay all bond premiums, costs, and incidentals. Each bond shall be signed by both the Contractor and surety and the signature of the authorized agent of the Surety shall be notarized. The Contractor shall provide two good and sufficient surety bonds: the payment bond and the faithful performance bond. 9.2 Payment Bond. The Payment Bond (material and labor) shall be for not less than one-hundred percent (100%) of the estimated cost of the construction and completion of the Work hereunder, as security for the payment of all persons performing labor and providing materials in connection with this Agreement and to satisfy claims of material suppliers and of mechanics and laborers contracted for the Work. The bond shall be maintained by the Contractor in full force and effect until the completed Work is accepted by the Town, and until all claims for materials and labor are paid. The bond shall provide that if the Contractor fails to pay any of its obligations, the surety will pay the obligation and, if an action is brought to enforce the liability on the bond, reasonable attorney’s fees. 9.3 Faithful Performance Bond. The Faithful Performance Bond shall be for 100% of the of the estimated cost of the construction and completion of the Work hereunder to guarantee faithful performance of all Work, within the time prescribed, in a manner satisfactory to the Town. 9.4 Warranty Bond. If, within a period of one (1) year after final acceptance of the work performed under this Agreement, the improvements installed or constructed, or caused to be installed or constructed by Contractor, or any of the work done under this Agreement, fails to fulfill any of the requirements of this Agreement or the specifications referred to herein, or proves to be defective or become damaged because of differential settlement, action of the elements, or ordinary usage, except for catastrophic events, Contractor shall without delay and without any cost to the Town repair or replace or reconstruct any defective or otherwise unsatisfactory part or parts of the work or structure. Should Contractor fail to act promptly or in accordance with this requirement, or should the exigencies of the case (as reasonably determined by Town) require repairs or replacements to be made before Contractor can be notified, Town may, at its option, make the necessary repairs or replacements or perform the necessary work, and Contractor shall pay to Town the actual cost of such repair plus fifteen (15%) percent. Contractor shall at the time of acceptance of the improvements by Town or other public agency, provide the Town with a corporate surety bond in the principal sum of not less than one-hundred percent (100%) of the cost of the construction and completion of the Work to secure the undertaking and obligations set forth in this provision. Minor Construction Agreement (revised Nov. 2023) 4 9.5 Bond Renewal and Extension If any bond becomes insufficient, the Contractor shall immediately replace the bond with a substitute upon request from the Town, and the effective date of the bond shall be from the beginning of Work. If any surety at any time is unsatisfactory to the Town, the Town will give notice to the Contractor. No further payments shall be deemed due or will be made under the Agreement until a new surety qualifies and is accepted by the Town. Changes in the Work, or extensions of time, made under the Agreement, shall not release the Contractor or surety from their obligations. The surety must waive notice of such changes or extensions. 10. Licenses. Contractor represents and warrants that Contractor possesses all licenses, permits, and qualifications legally required for the performance of the Work, including but not limited to a business license from the Town and payment of any applicable business license tax. Contractor shall, at Contractor’s sole cost and expense, maintain all such licenses, permits and qualifications in full force and effect throughout the term of this Agreement. 11. Damage to Town Facilities and Site Safety. Damage to Town or public facilities or private property caused by the Contractor or by its subcontractors during performance of the Work shall be repaired and/or replaced in kind at no cost to the Town. The worksite shall be kept clean and free of hazards at all times during installation. After work is completed at the site, Contractor shall clean the surrounding area to the condition prior to performance of the Work. 12. Final Inspection and Work Acceptance. All Work shall be subject to final inspection and acceptance or rejection by the Town. Contractor shall guarantee the Work to be free of defects in material and workmanship for a period of one (1) year following the Town’s acceptance of the Work. 13. Compliance with all Applicable Laws. A. Contractor shall comply with all applicable local, state and federal laws, regulations and ordinances in the performance of this Agreement. B. Contractor shall not discriminate in the provision of service or in the employment of persons engaged in the performance of this Agreement on account of race, color, national origin, ancestry, religion, gender, marital status, sexual orientation, age, physical or mental disability in violation of any applicable local, state or federal laws or regulations. C. Contractor shall comply with the requirements of the Secretary of Labor and the latest amendments to: Executive Orders 11246 and 11375, as supplemented in Department of Labor regulations (41 C.F.R. chapter 60); the Copeland “Anti- Kickback” Act (18 U.S.C. § 847) as supplemented in Department of Labor regulations (29 C.F.R. part 3); Section 3 of the Housing and Urban Development Act of 1968 (12 U.S.C. §§ 1701 et seq.); Title VI of the Civil Rights Act of 1964 (42 U.S.C. §§ 2000); Section 109 of Title I of the Housing and Community Development Act of 1974 (42 U.S.C. §§ 5301 et seq.); the Age Discrimination Act of 1975 (42 U.S.C. §§ 6101 et seq.); and Section 504 of the Rehabilitation Act of 1973 (29 U.S.C. §§ 701 et seq.) 14. Payment of Taxes; Tax Withholding. Contractor is solely responsible for the payment of employment taxes incurred under this Agreement and any similar federal or state taxes. To be exempt from tax withholding, Contractor must provide Town with a valid California Franchise Tax Board form 590 (“Form 590”). Unless Contractor provides Town with a valid Form 590 or other valid, written evidence of an exemption or waiver from withholding, Town may withhold California taxes from payments to Contractor as required by law. Contractor shall obtain, and maintain on file for three (3) years after the termination of this Agreement, Form 590s (or other written evidence of exemptions or waivers) from all Minor Construction Agreement (revised Nov. 2023) 5 subcontractors. Contractor accepts sole responsibility for withholding taxes from any non-California resident subcontractor and shall submit written documentation of compliance with Contractor’s withholding duty to Town upon request. 15. Prevailing Wage. A. The wages to be paid for a day's work to all classes of laborers, workmen, or mechanics on the work contemplated by this Agreement, shall be not less than the prevailing rate for a day’s work in the same trade or occupation in the locality within the state where the work hereby contemplates to be performed as determined by the Director of Industrial Relations pursuant to the Director’s authority under Labor Code Section 1770, et seq. Each laborer, worker or mechanic employed by Contractor or by any subcontractor shall receive the wages herein provided for. The Contractor shall pay two hundred dollars ($200), or whatever amount may be set by Labor Code Section 1775, as may be amended, per day penalty for each worker paid less than prevailing rate of per diem wages. The difference between the prevailing rate of per diem wages and the wage paid to each worker shall be paid by the Contractor to each worker. The Town will not recognize any claim for additional compensation because of the payment by the Contractor for any wage rate in excess of prevailing wage rate set forth. The possibility of wage increases is one of the elements to be considered by the Contractor. NOTE: An error on the part of an awarding body does not relieve the Contractor from responsibility for payment of the prevailing rate of per diem wages and penalties pursuant to Labor Code Sections 1770-1775. i. Posting of Schedule of Prevailing Wage Rates and Deductions. If the schedule of prevailing wage rates is not attached hereto pursuant to Labor Code Section 1773.2, the Contractor shall post at appropriate conspicuous points at the site of the project a schedule showing all determined prevailing wage rates for the various classes of laborers and mechanics to be engaged in work on the project under this contract and all deductions, if any, required by law to be made from unpaid wages actually earned by the laborers and mechanics so engaged. ii. Payroll Records. Each Contractor and subcontractor shall keep an accurate payroll record, showing the name, address, social security number, work week, and the actual per diem wages paid to each journeyman, apprentice, worker, or other employee employed by the Contractor in connection with the public work. Such records shall be certifies and submitted weekly as required by Labor Code Section 1776. 16. Patents. The Contractor shall assume all costs arising from the use of patented materials, equipment, services, or processes used on or incorporated in the Work, and agrees to indemnify and save harmless the Town of Los Altos Hills, the City Council, and the Engineer, and their duly authorized representatives, for all suits at law, or actions of every nature for, or on account of the use of any patented materials, equipment, services, or processes. 17. Dispute Resolution. Prior to initiating litigation in a court of competent jurisdiction, both Contractor and Town shall undergo alternative dispute procedures as outlined in Public Contract Code Section 20104, et seq. The Parties also expressly agree that such procedures are incorporated as though fully set forth in this Agreement. Minor Construction Agreement (revised Nov. 2023) 6 18. Prevailing Party. In the event that either party to this Agreement commences any legal action or proceeding (including but not limited to arbitration) to interpret the terms of this Agreement, the prevailing party in such a proceeding shall be entitled to recover its reasonable attorney’s fees associated with that legal action or proceeding. 19. Termination. Town may terminate or suspend this Agreement at any time and without cause upon written notification to Contractor. Upon receipt of notice of termination or suspension, Contractor shall immediately stop all work in progress under this Agreement. The Town’s right of termination shall be in addition to all other remedies available under law to the Town. 20. Severability. If any term or portion of this Agreement is held to be invalid, illegal, or otherwise unenforceable by a court of competent jurisdiction, the remaining provisions of this Agreement shall continue in full force and effect. 21. Entire Agreement. This Agreement represents the entire and integrated agreement between the Parties. This Agreement may be modified or amended only by a subsequent written agreement signed by both Parties. 22. Non-Liability of Officials, Employees and Agents. No officer, official, employee or agent of Town shall be personally liable to Contractor in the event of any default or breach by Town or for any amount which may become due to Contractor pursuant to this Agreement. 23. Execution in Counterparts. This Agreement may be executed in counterparts and/or by facsimile or other electronic means, and when each Party has signed and delivered at least one such counterpart, each counterpart shall be deemed an original, and, when taken together with other signed counterpart, shall constitute one Agreement, which shall be binding upon and effective as to all Parties. 24. Choice of Law; Venue. The applicable law shall be that of the State of California 25. Notice. All notices and other communications which are required or may be given under this Agreement shall be in writing and shall be deemed to have been duly given (i) when received if personally delivered; (ii) when received if transmitted by telecopy, if received during normal business hours on a business day (or if not, the next business day after delivery) provided that such facsimile is legible and that at the time such facsimile is sent the sending Party receives written confirmation of receipt; (iii) if sent for next day delivery to a domestic address by recognized overnight delivery service (e.g., Federal Express); and (iv) upon receipt, if sent by certified or registered mail, return receipt requested. In each case, notice shall be sent to the respective Parties as follows: Contractor: Sergey Leskin, President Fuse Service, Inc. 2222 Ronald Street Santa Clara, CA 95050 Town: WooJae Kim, Public Works Director Town of Los Altos Hills 26379 Fremont Road Los Altos Hills, CA 94022 Minor Construction Agreement (revised Nov. 2023) 7 IN WITNESS WHEREOF, the Parties have executed this Agreement as of the date written above. TOWN: CONTRACTOR: By:__________________________ By:__________________________ Cody Einfalt Sergey Leskin Acting City Manager President Minor Construction Agreement (revised Nov. 2023) 8 EXHIBIT A SCOPE OF WORK Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. MXZ-SM48NL 48,000 BTU/H HEAT PUMP OUTDOOR UNIT Job Name: System Reference:Date: Specifications System Unit Type MXZ-SM48NL Cooling at 95F1 (Non-Ducted // Mixed // Ducted) Maximum Capacity Btu/h 48,000 // 48,000 // 48,000 Rated Capacity Btu/h 48,000 // 48,000 // 48,000 Minimum Capacity Btu/h 15,000 // 15,000 // 15,000 Maximum Power Input W 4,000 // 4,710 // 5,715 Rated Power Input W 4,000 // 4,710 // 5,715 Power Factor (208V)%98.60 // 98.60 // 98.60 Power Factor (230V)%98.60 // 98.60 // 98.60 Heating at 47F2 (Non-Ducted // Mixed // Ducted) Maximum Capacity Btu/h 50,000 // 50,000 // 50,000 Rated Capacity Btu/h 50,000 // 50,000 // 50,000 Minimum Capacity Btu/h 13,000 // 13,000 // 13,000 Maximum Power Input W 3,665 // 4,140 // 4,730 Rated Power Input W 3,665 // 4,140 // 4,730 Power Factor (208V)%98.60 // 98.60 // 98.60 Power Factor (230V)%98.60 // 98.60 // 98.60 Heating at 17F3 (Non-Ducted // Mixed // Ducted) Maximum Capacity Btu/h 43,000 // 43,000 // 43,000 Rated Capacity Btu/h 31,400 // 32,400 // 33,400 Maximum Power Input W 6,305 // 6,705 // 7,160 Rated Power Input W 3,410 // 3,740 // 4,080 Heating at 5F4 (Non-Ducted // Mixed // Ducted)Maximum Capacity Btu/h 35,400 // 35,400 // 35,400 Maximum Power Input W 4,940 // 5,140 // 5,295 Heating at -13F8 (Non-Ducted // Mixed // Ducted)Maximum Capacity Btu/h 22,800 // 22,800 // 22,800 Maximum Power Input W 4,455 // 4,455 // 4,455 Efficiency (Non-Ducted // Mixed // Ducted) SEER21 23 // 20 // 17 EER21 12 // 10.20 // 8.40 HSPF2 (IV)2 10.40 // 9.95 // 9.50 COP at 47°F2 4 // 3.55 // 3.10 COP at 17°F at Maximum Capacity3 2 // 1.88 // 1.76 COP at 5°F at Maximum Capacity4 2.10 // 2.02 // 1.96 ENERGY STAR® Certified Yes // No // No NOTES 1Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB) 2Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB) 3Heating at 17°F (Indoor: 70°F DB, 60°F WB // Outdoor: 17°F DB, 15°F WB) 4Heating at 5°F (Indoor: 70°F DB, 60°F WB // Outdoor: 5°F DB, 4°F WB) 8Heating at -13°F (Indoor: 70°F DB, 60°F WB // Outdoor: -13°F DB, -14°F WB) • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. • A Maximum connected units reduced when PLA connected. Refer to manual for details • B Branch box should be placed within the level between the outdoor unit and indoor units • C 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. ** Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): • System cuts out in heating mode and automatically restarts at these temperatures. GENERAL FEATURES • Compatible with M- and P-Series and CITY MULTI® indoor units (branch box required for connection with M- and P-Series) • Compressor overcurrent detection • Compressor thermal protection • Fan motor overheating/voltage protection • High pressure protection • INVERTER-driven compressor: Compressor generates the precise capacity needed to maintain a temperature set point. • Quiet operation: Outdoor units are as quiet as a typical conversation, and most indoor units are whisper quiet. • Seacoast protection: Seacoast protection on heat exchanger and base panel (rated for 2,000 hrs. in accordance with ASTM B117 testing) • Thermal Differential 1°F Specifications System Unit Type MXZ-SM48NL Electrical Electrical Power Requirements V AC / V AC, , Hz 208 / 230, 1, 60 Guaranteed Voltage Range V AC 198 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 230 Short-circuit Current Rating (SCCR)kA 5 Recommended Fuse/Breaker Size if Branch Box Powered by Outdoor Unit A 40 Recommended Fuse/Breaker Size without Branch Box or Branch Box Powered Separate A 30 MCA if Branch Box Powered by Outdoor Unit A 42 MOCP if Branch Box Powered by Outdoor Unit A 70 MCA without Branch Box or Branch Box Powered Separate A 36 MOCP without Branch Box or Branch Box Powered Separate A 64 Outdoor Unit Fan Motor Output W 70+70 Defrost Method Reverse Cycle Blue Fin Heat Exchanger Coating Yes Sound Pressure Level, Cooling1 dB (A)51 Sound Pressure Level, Heating2 dB (A)54 Compressor Type Twin Rotary Compressor Model MRB36FEGMC-L Compressor Motor Output kW 3.4 Compressor Oil Type // Charge Type // oz RM68EH // 78 External Finish Color Munsell 3Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions (W x D x H)inch [mm] inch [mm] inch [mm]41-11/32 [1,050] 13 [330] 52-11/16 [1,338] Package Dimensions (W x D x H)inch [mm] inch [mm] inch [mm]43 [1,090] 18 [450] 58-5/16 [1,480] Unit Weight lbs [kg]250 [113] Package Weight lbs [kg]276 [125] ODU Operating Temp. Range Cooling Intake Air Temp (Maximum / MinimumC)°FDB 115 / 23 Cooling Thermal Lock-out / Re-start Temperatures °FDB N/A / N/A Heating Intake Air Temp (Maximum / Minimum)°FDB 70 / -13 Heating Thermal Lock-out / Re-start Temperatures**°FDB -24 / -14 Refrigerant Type R454B Pre-Charged Refrigerant Amount lbs, oz 2, 11 IDU Connection Maximum Number of Connected IDU with Branch BoxA 8 Maximum Number of Connected IDU without Branch Box 12 Minimum Connected Capacity with Branch Box Btu/h 12,000 Minimum Connected Capacity without Branch Box Btu/h 24,000 Maximum connected capacity Btu/h 62,400 Piping Liquid Pipe Size O.D. (Flared)inch [mm]3/8 [9.52] Gas Pipe Size O.D. (Flared)inch [mm]5/8 [15.88] Total Piping Length when using Branch Box ft [m]492 [150] Total Piping Length without Branch Box ft [m]787 [240] Maximum Height Difference*B, ODU above IDU ft [m]164 [50] Maximum Height Difference*B, ODU below IDU ft [m]131 [40] Maximum Height Difference*B, between branch boxes ft [m]39 [12] Maximum Height Difference between IDU and IDU without branch box ft [m]49 [15] Maximum Piping Length between ODU and Branch Box ft [m]180 [55] Farthest Piping Length from ODU to IDU with Branch Box ft [m]262 [80] Farthest Piping Length from ODU to IDU without Branch Box ft [m]262 [80] Farthest Piping Length after Branch Box ft [m]82 [25] Total Piping Length between Branch Boxes and IDU ft [m]312 [95] Maximum Number of Bends for IDU 15 NOTES 1Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB) 2Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB) 3Heating at 17°F (Indoor: 70°F DB, 60°F WB // Outdoor: 17°F DB, 15°F WB) 4Heating at 5°F (Indoor: 70°F DB, 60°F WB // Outdoor: 5°F DB, 4°F WB) 8Heating at -13°F (Indoor: 70°F DB, 60°F WB // Outdoor: -13°F DB, -14°F WB)• Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. • A Maximum connected units reduced when PLA connected. Refer to manual for details • B Branch box should be placed within the level between the outdoor unit and indoor units • C 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time.** Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): • System cuts out in heating mode and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: MXZ-SM48NL Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. OUTDOOR UNIT ACCESSORIES: MXZ-SM48NL Hail Guards Hail Guard HG-A2 Snow/Rain Diverter SnowRain Diverter SRD-5 Ball Valve Refrigeration Ball Valve - 1/2 BV12FFSI2 Refrigeration Ball Valve - 1/4 BV14FFSI2 Refrigeration Ball Valve - 3/8 BV38FFSI2 Refrigeration Ball Valve - 5/8 BV58FFSI2 Mini-Split Wire 14 Gauge 4 wire Armored MiniSplit Cable250 ft roll SW144-250 14 Gauge 4 wire Armored MiniSplit Cable50 ft roll SW144-50 14 Gauge 4 wire MiniSplit Cable250 ft roll S144-250 14 Gauge 4 wire MiniSplit Cable50 ft roll S144-50 16 Gauge 4 wire Armored MiniSplit Cable250 ft roll SW164-250 16 Gauge 4 wire Armored MiniSplit Cable50 ft roll SW164-50 16 Gauge 4 wire MiniSplit Cable250 ft roll S164-250 Control Wire M-Net Control Wire 1000 Roll 16-AWG Standard Twisted Pair Shielded Jacketed- Plenum rated CW162S-1000 M-Net Control Wire 250 Roll 16-AWG Standard Twisted Pair Shielded Jacketed- Plenum rated CW162S-250 Port Adaptor Adaptor 1/4 x 3/8 PAC-SJ87RJ-E Adaptor 12 x 38 PAC-SK88RJ-E Adaptor 12 x 58 PAC-SK89RJ-E Adaptor 38 x 12 ADP3812 Adaptor 38 x 58 PAC-SK90RJ-E Stand 18 Dual Fan Stand QSMS1802M 24 Dual Fan Stand QSMS2402M Condenser Wall Bracket QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish QSWBSS Outdoor Unit 3-14 inch Mounting Base Pair - Plastic DSD-400P Outdoor Unit Stand 12 High QSMS1202M Wind Baffle Front Wind Baffle WB-PA3 (two pieces are required) Branch Box 3 Port Branch Box PAC-LMA30BC 5 Port Branch Box PAC-LMA50BC Branch Box Enclosure BBE-1 Power Supplies & Auxiliary Components 3-Pin Wiring Harness PAC-715AD 5-Pin Wiring Harness PAC-725AD Control/Service Tool Maintenance Tool Interface PAC-USCMS-MN-1 Drain Socket Drain Socket PAC-SG60DS-E Centralized Drain Pan Centralized Drain Pan PAC-SH97DP-E Optional Defrost Heater Optional Defrost Heater PAC-SJ20BH-E Mounting Pad Condensing Unit Mounting Pad 24 x 42 x 3 ULTRILITE2 Distribution pipe Brazed Connection MSDD-50BR-E Flare Connection MSDD-50AR2-E Air Deflector Vertical Air Deflector ADV-1 Alarm Kit Alarm Kit PAC-SL54AL-E Alarm Kit Interface PAC-IF55AL-E Air Outlet Guide Air Outlet Guide 1 Piece PAC-SH96SG-E (two pieces are required) NOTES Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. METUS_2025-02_PROPIN 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 https://mitsubishicomfort.com OUTDOOR UNIT DIMENSIONS: MXZ-SM48NL Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. MXZ-2D20NL 20,000 BTU/H HEAT PUMP OUTDOOR UNIT Job Name: System Reference:Date: Specifications System Unit Type MXZ-2D20NL Cooling at 95F1 (Non-Ducted // Mixed // Ducted) Maximum Capacity Btu/h 20,000 // 21,000 // 22,000 Rated Capacity Btu/h 18,000 // 19,000 // 20,000 Minimum Capacity Btu/h 5,700 // 5,700 // 5,700 Maximum Power Input W 2,245 // 2,257 // 2,270 Rated Power Input W 1,384 // 1,692 // 2,000 Power Factor (208V)%0.99 // 0.99 // 0.99 Power Factor (230V)%0.99 // 0.99 // 0.99 Heating at 47F2 (Non-Ducted // Mixed // Ducted) Maximum Capacity Btu/h 25,700 // 25,750 // 25,800 Rated Capacity Btu/h 24,000 // 22,000 // 23,000 Minimum Capacity Btu/h 7,400 // 7,400 // 7,400 Maximum Power Input W 2,465 // 2,498 // 2,530 Rated Power Input W 1,794 // 1,783 // 1,771 Power Factor (208V)%0.99 // 0.99 // 0.99 Power Factor (230V)%0.99 // 0.99 // 0.99 Heating at 17F3 (Non-Ducted // Mixed // Ducted) Maximum Capacity Btu/h 16,600 // 16,200 // 15,800 Rated Capacity Btu/h 16,500 // 15,000 // 13,500 Maximum Power Input W 1,860 // 1,910 // 1,960 Rated Power Input W 1,690 // 1,590 // 1,490 Heating at 5F4 (Non-Ducted // Mixed // Ducted)Maximum Capacity Btu/h 13,700 // 12,600 // 11,800 Maximum Power Input W 1,800 // 1,815 // 1,830 Efficiency (Non-Ducted // Mixed // Ducted) SEER21 20 // 18 // 16 EER21 13 // 11.50 // 10 HSPF2 (IV)2 10 // 9.55 // 9.10 COP at 47°F2 3.92 // 3.76 // 3.64 COP at 17°F at Maximum Capacity3 2.60 // 2.48 // 2.36 COP at 5°F at Maximum Capacity4 2.23 // 2.04 // 1.88 ENERGY STAR® Certified Yes // Yes // No Electrical Electrical Power Requirements V AC / V AC, ø, Hz 208 / 230, 1, 60 Guaranteed Voltage Range V AC 198 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Recommended Wire Size (Indoor - Outdoor)AWG 14 Short-circuit Current Rating (SCCR)kA 5 MCA A 21.7 MOCP A 38 NOTES 1Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB) 2Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB) 3Heating at 17°F (Indoor: 70°F DB, 60°F WB // Outdoor: 17°F DB, 15°F WB) 4Heating at 5°F (Indoor: 70°F DB, 60°F WB // Outdoor: 5°F DB, 4°F WB) Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer to Multi-zone Outdoor Unit Oper- ational Performance.For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. * Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): • System cuts out in heating mode and automatically restarts at these temperatures. GENERAL FEATURES • Compact, small chassis • Compressor overcurrent detection • Compressor thermal protection • Fan motor overheating/voltage protection • Freeze-prevention base pan heater equipped as standard • High-pressure protection • Prolonged heating over an extended duration • Quiet outdoor unit operation as low as 52 dB(A) • Rated for 2,000 hours spraying time per ASTM B117 Standard • Variable speed INVERTER-driven compressor • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications System Unit Type MXZ-2D20NL Outdoor Unit Fan Motor Full Load Amperage A 1.77 Fan Motor Output W 64 Defrost Method Reverse Cycle Blue Fin Heat Exchanger Coating Yes Airflow Rate Cooling/Heating CFM 1,324 / 1,451 Sound Pressure Level, Cooling1 dB (A)51 Sound Pressure Level, Heating2 dB (A)55 Compressor Type Twin Rotary Compressor Model SRB140FQHM1T Compressor Oil Type // Charge Type // oz RM68EH // 20.3 External Finish Color Munsell 3.0Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions (W x D x H)inch x inch x inch [mm x mm x mm]33-1/16 x 13 x 27-15/16 [840 x 330 x 710] Package Dimensions (W x D x H)inch x inch x inch [mm x mm x mm]38-31/32 x 17-5/16 x 34-21/32 [990 x 440 x 880] Unit Weight lbs [kg]119 [54] Package Weight lbs [kg]137 [62] ODU Operating Temp. Range Cooling Intake Air Temp (Maximum / Minimum)°FDB 115 / 14 Cooling Thermal Lock-out / Re-start Temperatures °FDB 10 / 14 Heating Intake Air Temp [Maximum / Minimum]°FDB, °FWB / °FDB, °FWB 75, 65 / 6, 5 Heating Thermal Lock-out / Re-start Temperatures**°FDB -4 / 5 Refrigerant Type R454B Pre-Charged Refrigerant Amount lbs, oz 4, 7 Maximum Pre-Charged Piping Length ft 164 IDU Connection Minimum Number of Connected IDU 2 Maximum Number of Connected IDU 2 Minimum Connected Capacity Btu/h 12,000 Maximum connected capacity Btu/h 24,000 Piping Liquid Pipe Size O.D. (Flared)inch A: 1/4 B: 1/4 Gas Pipe Size O.D. (Flared)inch A: 3/8 B: 3/8 Total Piping Length ft [m]164 [50] Farthest Piping Length ft [m]82 [25] Maximum Height Difference, ODU above IDU ft [m]32 [10] Maximum Height Difference, ODU below IDU ft [m]49 [15] Maximum Number of Bends for IDU 50 NOTES 1Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB) 2Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB) 3Heating at 17°F (Indoor: 70°F DB, 60°F WB // Outdoor: 17°F DB, 15°F WB) 4Heating at 5°F (Indoor: 70°F DB, 60°F WB // Outdoor: 5°F DB, 4°F WB)Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer to Multi-zone Outdoor Unit Oper- ational Performance. For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. * Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): • System cuts out in heating mode and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: MXZ-2D20NL Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. OUTDOOR UNIT ACCESSORIES: MXZ-2D20NL Port Adaptor Adaptor 1/2 x 3/8 PAC-SK88RJ-E Adaptor 1/2 x 5/8 PAC-SK89RJ-E Adaptor 1/4 x 3/8 PAC-493PI Adaptor 3/8 x 1/2 ADP3812 Adaptor 3/8 x 5/8 PAC-SK90RJ-E Ball Valve Refrigeration Ball Valve - 1/2 BV12FFSI2 Refrigeration Ball Valve - 1/4 BV14FFSI2 Refrigeration Ball Valve - 3/8 BV38FFSI2 Refrigeration Ball Valve - 5/8 BV58FFSI2 Mini-Split Wire 14 Gauge 4 wire Armored MiniSplit Cable250 ft roll SW144-250 14 Gauge 4 wire Armored MiniSplit Cable50 ft roll SW144-50 14 Gauge 4 wire MiniSplit Cable250 ft roll S144-250 14 Gauge 4 wire MiniSplit Cable50 ft roll S144-50 16 Gauge 4 wire Armored MiniSplit Cable250 ft roll SW164-250 16 Gauge 4 wire Armored MiniSplit Cable50 ft roll SW164-50 16 Gauge 4 wire MiniSplit Cable250 ft roll S164-250 16 Gauge 4 wire MiniSplit Cable50 ft roll S164-50 Air Outlet Guide Air Outlet Guide MAC-856SG Hail Guards Hail Guard HG-A8 Stand 18 Single Fan Stand QSMS1801M 24 Single Fan Stand QSMS2401M Condenser Wall Bracket QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish QSWBSS Outdoor Unit 3-14 inch Mounting Base Pair - Plastic DSD-400P Outdoor Unit Stand 12 High QSMS1201M Control/Service Tool Maintenance Tool Interface PAC-USCMS-MN-1 Optional Defrost Heater Optional Defrost Heater PAC-646BH-E Control Interface M-NET Interface for MXZ PAC-IF01MNT-E Drain Socket Drain Socket MAC-811DS Mounting Pad Condensing Unit Mounting Pad 16 x 36 x 3 ULTRILITE1 Snow/Rain Diverter SnowRain Diverter SRD-4 Muffler Muffler MAC-001MF-E NOTES Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. METUS_2025-03_PROPIN 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 https://mitsubishicomfort.com MXZ-2D20NL-U1 Connectingwire hole 1-25/32”18-1/829/32”3-5/16”5-5/16”11-25/32”14-3/16”27-15/16”9-7/16”7-7/8” 1-3/16”33-1/16”13/32” Unit AGAS GAS LIQ LIQ LIQ 1/4”(ø6.35)FLAREGAS 3/8”(ø9.52)FLARE Unit B Connectingwire hole 1-1/32”13” 2-19/32” 1/2”(Bolt Pitch)(Foundation Bolt M8) 4-(13/32”×13/16”) Oval Hole 3-ø(1-5/16”) Drain hole AirInlet Air Inlet AirOutlet 14-3/16”15/32”23/32”21/32”1-11/32”2-9/16”12-3/8”8-5/32” 6-21/32”6-23/32”19-11/16”11/16”11/16”15-19/32”Handle OUTDOOR UNIT DIMENSIONS: MXZ-2D20NL Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. PLFY-L15NFMU-A 15,000 BTU/H CEILING CASSETTE INDOOR UNIT Job Name: System Reference:Date: Specifications System Unit Type PLFY-L15NFMU-A Cooling Capacity (Nominal)1,3 Cooling Capacity (Nominal)Btu/h 15,000 Heating Capacity (Nominal)2,3 Heating Capacity (Nominal)Btu/h 17,000 Electrical Voltage, Phase, Frequency V AC / V AC, , Hz 208 / 230, 1, 60 Power Consumption Cooling kW 0.03 Power Consumption Heating kW 0.03 Current Cooling A 0.28 Current Heating A 0.23 MCA A 0.36 MOCP A 15 Indoor Unit Fan Motor Type DC Motor Fan Motor Output W 50 Airflow Rate at Cooling, Dry CFM 265, 315, 390 Airflow Rate at Heating, Dry CFM 265, 315, 390 Sound Pressure Level [Heating]dB (A)28, 33, 39 DBC on HEX (Yes or No)No External Finish Color 1.0Y 9.2/0.2 Unit Dimensions (W x D x H)inch x inch x inch [mm x mm x mm]22-7/16 x 22-7/16 x 8-3/16 [570 x 570 x 208] Package Dimensions (W x D x H)inch x inch x inch [mm x mm x mm]28 x 24-7/16 x 9-8/16 [710 x 620 x 240] Unit Weight lbs [kg]31.3 [14.20] Package Weight lbs [kg]37 [17] Refrigerant Type R454B Piping Liquid Pipe Size O.D. [Flared]inch [mm]1/4 [6.35] Gas Pipe Size O.D. [Flared]inch [mm]1/2 [12.7] NOTES 1Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB) 2Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB) 3Nominal capacity only. Actual capacity output varies based on the system-specific configuration. GENERAL FEATURES • 2’ x 2’ size matches size of many ceiling tiles • 3D Turbo fan: 3D turbo fan enabling increased airflow • 3D i-See sensor® settings requires the PAR-40MAAU controller • 3D i-see Sensor® (Optional): *Requires a PAR-33MAA-J controller • Airflow Pattern Selection: There are three outlet options available: bidirectional, three-way, and four-way—to fit different installation types. • Built-in condensate lift: Reduces the need for an additional pump to remove condensate water; designed to provide up to 33″ of lift • Corner pocket design: Corner pocket design for simplified installation • Energy saving features • Four fan speed: Four fan speed settings including auto-fan • Improved occupant comfort • Independent Vane Angle Settings: Vane direction can be changed or fixed from the remote controller to direct the supply air toward or away from objects or occupants in the room. The airflow direction of each vane can be set using the wired remote controller or wireless remote controller (PAR- FL32MA). • Occupancy Detection • Square edge, sleek design • Ventilation air intake supported Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. INDOOR UNIT ACCESSORIES: PLFY-L15NFMU-A Power Supplies & Auxiliary Components 3-Pin Wiring Harness PAC-715AD 5-Pin Wiring Harness PAC-725AD Wired Remote Controller Deluxe Wired MA Remote Controller 1 PAR-42MAAUB Simple Direct Wired Remote Controller PAC-SDW01RC-1 Simple MA Remote Controller 1 PAC-YT53CRAU-J Smart ME Remote Controller PAR-U01MEDU-K Touch MA Wired Remote Controller 1 PAR-CT01MAU-SB Power Supplies and Auxiliary Components Backup Heat Relay Kit Adapter for CN24 or CN152 Connector CN24RELAY-KIT-CM3 Remote Sensor Flush Mount Remote Temperature Sensor for SEZ SLZ SVZ and all P-Series models PAC-USSEN002-FM-1 Wall Mount Remote Temperature Sensor PAC-SE41TS-E Wireless temperature and humidity sensor for the Comfort app PAC-USWHS003-TH-1 Wireless Remote Controller Lockdown Bracket for Wireless Handheld Remote Controllers RCMKP1CB RedLINK Wireless Remote Controller MHK2 Universal Wireless MA Handheld Remote Controller PAR-FL32MA-E Universal Wireless Receiver for PAR-FL32MA-E PAR-FA32MA-W Wireless Handheld Remote Controller for SLZ PLA and PLFY models PAR-SL101A-E Wireless Receiver for PAR-SL101A-E on PLA-NL and PLFY-ELNEMU models PAR-SR4LU-E Wireless Signal Receiver for PAR-SL101A-E on SLZ-AF and PLFY-NFMU models PAR-SF9FA-E Control Interface Airzone Wired Blueface Controller Black AZZBSBLUEZEROCN Airzone Wired Blueface Controller White AZZBSBLUEZEROCB Airzone Wireless Lite Controller Black AZZBSLITERN Airzone Wireless Lite Controller White AZZBSLITERB Airzone Wireless Think Controller Black AZZBSTHINKRN Airzone Wireless Think Controller White AZZBSTHINKRB IT Extender for kumo station PAC-WHS01IE-E kumo station for the Comfort app PAC-WHS01HC-E Procon BACnet and Modbus Interface PAC-UKPRC001-CN-1 Thermostat Interface for 3rd Party Thermostats PAC-US445CN-1 Wireless Interface Adapter for the Comfort app PAC-USWHS002-WF-2 i-see Sensor® Panel 3D i-See Sensor Corner Panel for PLFY-NFMU models PAC-SF1ME-E 3D i-See Sensor Grille SLP-18FAEU Condensate Blue Diamond Advanced Mini Condensate Pump w Reservoir Sensor 208230V recommended X87-721 Blue Diamond MaxiBlue Advanced Mini Condensate Pump w Reservoir Sensor 110V up to 48000 BTUH recommended X87-711 Blue Diamond MegaBlue Advanced Condensate Pump w Reservoir Sensor X87-835 Blue Diamond MicroBlue Mini Condensate Pump 110208230V up to 18000 BTUH X86-003 Blue Diamond Sensor Extension Cable 15 Ft C13-103 Refco Condensate Pump 100-240 VAC up to 120000 BTUH COMBI Grille Grille (required) SLP-18FAU NOTES Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. METUS_2025-02_PROPIN 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 https://mitsubishicomfort.com INDOOR UNIT DIMENSIONS: PLFY-L15NFMU-A Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SLZ-AF09NL 9,000 BTU/H CEILING CASSETTE INDOOR UNIT Job Name: System Reference:Date: Specifications System Unit Type SLZ-AF09NL Cooling Capacity (Nominal)1,3 Cooling Capacity (Nominal)Btu/h 9,000 Heating Capacity (Nominal)2,3 Heating Capacity (Nominal)Btu/h 11,000 Electrical Voltage, Phase, Frequency V AC / V AC, ø, Hz 208 / 230, 1, 60 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 12-24 MCA A 1 MOCP A 15 Indoor Unit Fan Motor Type DC Motor Fan Motor Output W 50 Airflow Rate at Cooling, Dry CFM 230, 265, 300 Airflow Rate at Cooling, Wet CFM 207, 239, 270 Airflow Rate at Heating, Dry CFM 230, 265, 300 Sound Pressure Level [Cooling]dB (A)25, 28, 31 Sound Pressure Level [Heating]dB (A)25, 28, 31 DBC on HEX (Yes or No)No External Finish Color 1.0Y 9.2/0.2 Unit Dimensions (W x D x H)inch x inch x inch [mm x mm x mm]22-7/16 x 22-7/16 x 8-4/16 [570 x 570 x 208] Package Dimensions (W x D x H)inch x inch x inch [mm x mm x mm]28 x 24-13/32 x 9-29/64 [710 x 620 x 240] Unit Weight lbs [kg]31 [14] Package Weight lbs [kg]36 [16.50] Refrigerant Type R454B Piping Liquid Pipe Size O.D.inch [mm]1/4 [6.35] Gas Pipe Size O.D.inch [mm]3/8 [9.52] Drain Pipe Drain Pipe Size O.D.inch [mm]1-1/4 [32] NOTES 1Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB) 2Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB) 3Nominal capacity only. Actual capacity output varies based on the system-specific configuration. GENERAL FEATURES • Built-in drain condensate lift mechanism (lifts to 33”) • Ceiling-recessed cassette : Ceiling-recessed cassette (24”x24”) • Fresh air intake: Fresh air intake provided in the main body • Individual vane control • Install Konnect Series: Install Konnect Series in a drywalled ceiling (with an access panel for servicing) or in a 2’x2’ drop ceiling • Light commercial: Units with this icon are suitable for light commercial applications such as small offices, restaurants, and retail. • Long-life air filter included • Multi-zone: A multi-zone unit provides the temperature management of multiple zones within a building. • Multiple control options, including the comfort app for remote access, third- party interfaces, and both wired and wireless controllers • Optional 3D i-see Sensor®: The advanced sensor scans each room to produce a complete thermal profile that includes heat signatures based upon size, temperature and movement, then adjusts temperature and airflow based on user preference, and saves energy according to room occupancy. • Powerful Mode: Temporarily drops or raises the set point and fan speed in order to quickly bring the room to the desired temperature. • Up and down swing-mode: An indoor unit with this capability can move air up and down throughout the room like an oscillating fan using the horizontal vanes. • Wide airflow pattern: Wide airflow pattern for excellent air distribution Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. INDOOR UNIT ACCESSORIES: SLZ-AF09NL Condensate Blue Diamond Advanced Mini Condensate Pump w Reservoir Sensor 208230V recommended X87-721 Blue Diamond MaxiBlue Advanced Mini Condensate Pump w Reservoir Sensor 110V up to 48000 BTUH recommended X87-711 Blue Diamond MegaBlue Advanced Condensate Pump w Reservoir Sensor X87-835 Blue Diamond MicroBlue Mini Condensate Pump 110208230V up to 18000 BTUH X86-003 Blue Diamond Sensor Extension Cable 15 Ft C13-103 Refco Condensate Pump 100-240 VAC up to 120000 BTUH COMBI Sauermann Condensate Pump SI30-230 Power Supplies and Auxiliary Components Backup Heat Relay Kit Adapter for CN24 or CN152 Connector CN24RELAY-KIT-CM3 Remote Sensor Flush Mount Remote Temperature Sensor for SEZ SLZ SVZ and all P-Series models PAC-USSEN002-FM-1 Wall Mount Remote Temperature Sensor PAC-SE41TS-E Wireless temperature and humidity sensor for the Comfort app PAC-USWHS003-TH-1 Control Interface Airzone Wired Blueface Controller Black AZZBSBLUEZEROCN Airzone Wired Blueface Controller White AZZBSBLUEZEROCB Airzone Wireless Lite Controller Black AZZBSLITERN Airzone Wireless Lite Controller White AZZBSLITERB Airzone Wireless Think Controller Black AZZBSTHINKRN Airzone Wireless Think Controller White AZZBSTHINKRB IT Extender for kumo station PAC-WHS01IE-E kumo station for the Comfort app PAC-WHS01HC-E Operation and Error Status Output Adapter 1 PAC-SF40RM-E Procon BACnet and Modbus Interface PAC-UKPRC001-CN-1 Thermostat Interface for 3rd Party Thermostats PAC-US445CN-1 Wireless Interface Adapter for the Comfort app PAC-USWHS002-WF-2 Wireless Remote Controller Lockdown Bracket for Wireless Handheld Remote Controllers RCMKP1CB RedLINK Wireless Remote Controller MHK2 Universal Wireless MA Handheld Remote Controller PAR-FL32MA-E Universal Wireless Receiver for PAR-FL32MA-E PAR-FA32MA-W Wireless Handheld Remote Controller for SLZ PLA and PLFY models PAR-SL101A-E Wireless Receiver for PAR-SL101A-E on PLA-NL and PLFY-ELNEMU models PAR-SR4LU-E Wireless Signal Receiver for PAR-SL101A-E on SLZ-AF and PLFY-NFMU models PAR-SF9FA-E Wired Remote Controller Deluxe Wired MA Remote Controller PAR-42MAAUB Simple Direct Wired Remote Controller PAC-SDW01RC-1 Simple MA Remote Controller 1 PAC-YT53CRAU-J Touch MA Wired Remote Controller 1 PAR-CT01MAU-SB Power Supplies & Auxiliary Components 3-Pin Wiring Harness PAC-715AD 5-Pin Wiring Harness PAC-725AD i-see Sensor® Panel 3D i-See Sensor Grille SLP-18FAEU Disconnect Switch 30A600VUL fits 2 X 4 utility box - Black TAZ-MS303 30A600VUL fits 2 X 4 utility box - White TAZ-MS303W Lineset 15 x 1/4 x 15 3/8 Lineset Twin-Tube Insulation MLS143812T-15 30 x 1/4 x 30 3/8 Lineset Twin-Tube Insulation MLS143812T-30 50 x 1/4 x 50 3/8 Lineset Twin-Tube Insulation MLS143812T-50 65 x 1/4 x 65 3/8 Lineset Twin-Tube Insulation MLS143812T-65 Grille Grille (required) SLP-18FAU NOTES 1Requires MAC-334IF-E Interface to connect MA controller 1Unable to use with Wireless Handheld Remote Controller 1Requires MAC-334IF-E Interface to connect MA controller 1Requires MAC-334IF-E Interface to connect MA controller 1Requires MAC-334IF-E Interface to connect MA controller Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. METUS_2025-05_PROPIN 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 https://mitsubishicomfort.com INDOOR UNIT DIMENSIONS: SLZ-AF09NL Project: LOS ALTOS HILLS TOWN HALL Address: LOS ALTOS HILLS, CALIFORNIA Date of Bid: January 15, 2026 FUSE SERVICE, INC. 2222 Ronald St, Santa Clara, CA 95050 (408) 300 3343 sergey@fuseservice.com Bid Proposal CSLB Number 1052421 B General Building C10 Electrical, C20 Warm-Air Heating, Ventilating and Air- Conditioning, C36 Plumbing, C38 Refrigeration DIR # 100084353 To: Los Altos Hills Town Hall From: Sergey Leskin Fuse Service Contact Info: mschloetter@losaltoshill.ca.gov Contact Info: Phone: (408) 300 3343 sergey@fuseservice.com Base Bid Included Scope of work: I. Install (3) new heat pump outdoor units. II. Install (7) 4-way ceiling cassette. III. Install (6) wall thermostats. IV. Install (1) subpanel. V. Install refrigerant pipes, condensate pipes, electrical lines, thermostat wires. VI. Permit and Title 24. VII. Reconnect existing fresh system to new (7) 4-way ceiling cassette. Equipment specs are attached. VIII. Demo of existing equipment (air handlers, condensing unit, refrigerant pipes, thermostats, ductwork). IX. MEP + AR + STR drawings Notes: Prevailing wage is included. Delivery and transport fee is included. Equipment in stock. Crane operator service is included. Demo of existing equipment is included. We will patch all outdoor penetrations and patch small holes inddor after we take off thermostats. Labor warranty is 3 years. Parts warranty is 10 years. Approximately the time line for the work w/out permit process is 3 weeks. Drawings set build up approximetaly 8 weeks. Total price is $145,000.00. Excluded - Any additional service not included in scope of work (if city or owner ask). - Painting is excluded Today date 01/15/2026 Proposal valid for 30 days Any questions regarding this proposal please contact sergey@fuseservice.com SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED? (Mandatory in NH) DESCRIPTION OF OPERATIONS below If yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIRED AUTOS ONLY 01/21/2026 Fuse Service Inc 2222 Ronald St Santa Clara, CA 95050 Francis X Murphy Insurance Agency Inc 21 Edinburgh Drive Palm Beach Gardens FL 33418 Fax:Phone: Canopiois US Insurance Inc 12961 19175386419 12126878725 andrew@murphyagencies.com Francis X Murphy Insurance Agency Inc A ✔ ✔ ✔ ✔X 09-06-2025 09-06-2026 CUSPC19000663-00 1,000,000 50,000 5,000 2,000,000 2,000,000 1,000,000 A ✔ ✔ ✔CUSXS20000343-00 09-06-2025 09-06-2026 5,000,000 5,000,000 Certificate Holder is named as an Additional Insured per written contract. Waiver of Subrogation is included. See attached. Francis Murphy The Town of Los Altos Hills 26379 Fremont Road Los Altos Hills, CA 94022 POLICY NUMBER: CUSPC19000663-00 COMMERCIAL GENERAL LIABILITY CG 20 10 07 04 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. CG 20 10 07 04 © ISO Properties, Inc., 2004 Page 1 of 1 ADDITIONAL INSURED ¦OWNERS, LESSEES OR ¦CONTRACTORS SCHEDULED PERSON OR ORGANIZATIONPRIMARY AND NON CONTRIBUTORY This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART SCHEDULE Name Of Additional Insured Person(s) Or Organization(s): Location(s) Of Covered Operations All persons or organization where written contract with the named insured requires additional insured status. This form does not apply to your work on new “Residential Property”. All locations at which you are performing operations for any person or organization with whom or with which you have agreed in writing in a contract or agreement that such person(s) or organization(s) shall be included as an additional insured on your policy. Information required to complete this Schedule, if not shown above, will be shown in the Declarations. A. Section ¦ II Who Is An Insured is amended to include as an additional insured the person(s) or organization(s) shown in the Schedule, but only with respect to liability for "bodily injury", "property damage" or "personal and advertising injury" caused, in whole or in part, by: 1.Your acts or omissions; or 2.The acts or omissions of those acting on your behalf; in the performance of your ongoing operations for the additional insured(s) at the location(s) designated above. B.With respect to the insurance afforded to these additional insureds, the following additional exclusions apply: This insurance does not apply to "bodily injury" or "property damage" occurring after: 1.All work, including materials, parts or equipment furnished in connection with such work, on the project (other than service, maintenance or repairs) to be performed by or on behalf of the additional insured(s) at the location of the covered operations has been completed; or 2.That portion of "your work" out of which the injury or damage arises has been put to its intended use by any person or organization other than another contractor or subcontractor engaged in performing operations for a principal as a part of the same project. POLICY NUMBER: CUSPC19000663-00 COMMERCIAL GENERAL LIABILITY CG 20 37 07 04 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. CG 20 37 07 04 © ISO Properties, Inc., 2004 Page 1 of 1 ADDITIONAL INSURED ¦OWNERS, LESSEES OR ¦CONTRACTORS COMPLETED OPERATIONS This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART SCHEDULE Name Of Additional Insured Person(s) Or Organization(s): Location And Description Of Completed Operations All Persons or organizations where written contract with the Named Insured requires additional insured completed operations coverage. This form does not apply to your work on new “Residential Property” All locations at which you are performing operations for any person or organization with whom or with which you have agreed in writing in a contract or agreement that such person(s) or organization(s) shall be included as an additional insured on your policy. Information required to complete this Schedule, if not shown above, will be shown in the Declarations. Section II¦Who Is An Insured is amended to include as an additional insured the person(s) or organization(s) shown in the Schedule, but only with respect to liability for "bodily injury" or "property damage" caused, in whole or in part, by "your work" at the location designated and described in the schedule of this endorsement performed for that additional insured and included in the "products- completed operations hazard". POLICY NUMBER: CUSPC19000663-00 COMMERCIAL GENERAL LIABILITY CG 24 04 12 19 THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY. WAIVER OF TRANSFER OF RIGHTS OF RECOVERY AGAINST OTHERS TO US (WAIVER OF SUBROGATION) This endorsement modifies insurance provided under the following: COMMERCIAL GENERAL LIABILITY COVERAGE PART ELECTRONIC DATA LIABILITY COVERAGE PART LIQUOR LIABILITY COVERAGE PART POLLUTION LIABILITY COVERAGE PART DESIGNATED SITES POLLUTION LIABILITY LIMITED COVERAGE PART DESIGNATED SITES PRODUCTS/COMPLETED OPERATIONS LIABILITY COVERAGE PART RAILROAD PROTECTIVE LIABILITY COVERAGE PART UNDERGROUND STORAGE TANK POLICY DESIGNATED TANKS SCHEDULE The following is added to Paragraph 8. Transfer Of Rights Of Recovery Against Others To Us of Section IV - Conditions: We waive any right of recovery against the person(s) or organization(s) shown in the Schedule above because of payments we make under this Coverage Part. Such waiver by us applies only to the extent that the insured has waived its right of recovery against such person(s) or organization(s) prior to loss. This endorsement applies only to the person(s) or organization(s) shown in the Schedule above. CG 24 04 12 19 © Insurance Services Office, Inc., 2018 Page 1 of 1 Information required to complete this Schedule, if not shown above, will be shown in the Declarations. Name Of Person(s) Or Organization(s): All persons or organizations where required by written contract with the Named Insured signed by both parties prior to loss. SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED? (Mandatory in NH) DESCRIPTION OF OPERATIONS below If yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIRED AUTOS ONLY 1/22/2026 Broad Spectrum Insurance Services 1000 Brannan Street,Suite 205 San Francisco CA 94103 Alberto Medina 415-852-7425 alberto@calinsurancepro.com License#:0F49732 Technology Insurance Company,42376 FUSESER-01 Atain Specialty Ins Co 17159FuseService,Inc.DBA Fuse HVAC Refrigeration Electrical & Plumbing 2222 Ronald St Santa Clara CA 95050 Arch Insurance Company 11150 777421617 C 1,000,000 X X X 01306452 12/19/2025 12/19/2026 A X Y Y TWP4611818 4/15/2025 4/15/2026 1,000,000 1,000,000 1,000,000 B Commercial Property CIP476905 6/20/2025 6/20/2026 Business Property 380,000 Town of Los Altos Hills is afforded waiver of subrogation status for workers’compensation only per written agreement or contract. Town of Los Altos Hills 26379 Fremont Road Los Altos Hills CA 94022