HomeMy WebLinkAboutItem 3.1Item 3.1 TOWN OF LOS ALTOS HILLS May 7, 2009 Staff Report to the Planning Commission RE: SITE DEVELOPMENT PERMIT FOR A TWO STORY NEW RESIDENCE WITH A BASEMENT, SECONDARY UNIT (CABANA), AND SWIMMING POOL; LANDS OF AGAM, 25611 VINEDO LANE (LOT # 3); FILE #315-08- ZP-SD-GD (CONTINUED FROM APRIL 2, 2009). FROM: David Keyon, Associate Planner APPROVED BY: Debbie Pedro Planning Director RECOMMENDATION: That the Planning Commission: Approve the requested Site Development Permit subject to the revised plans and recommended conditions of approval in Attachment 1. BACKGROUND On April 2, 2009 the Planning Commission continued this project with specific direction for the applicant to move the house and driveways back (north) 10 additional feet to reduce the amount of driveway located within the setback along the southeastern property line. This will provide an additional 10' of undeveloped area within the setbacks for future landscape screening to mitigate potential visual and privacy impacts for the neighbor to the south. DISCUSSION: To address the Commission's direction, the applicant moved the house back 5 to 10 feet so the driveway to the basement garage could be moved 10 feet further from the southwestern property line. The floor area is the same as the previous proposal, and basement has been reduced in size by about 88 square feet due to a reduction in the size of the "au -pair" unit. The length of the patio between the pool and main residence was also reduced by 5 feet in order to accommodate the new location of the residence. To stay within the height and grading limits of the first proposal, the finished floor elevation of the main level increased one foot, from 438.5 feet to 439.5 feet. The maximum height will remain under the 27 foot height limit (at 26'-6") and the overall (lowest point to highest point) height will be 34'-10". A grading policy exception for up to 11' of out for the driveway and basement garage is still requested. As in the previous design, the proposed grading will help lower the profile of the new home. Furthermore, the driveway retaining walls will be below natural grade and will not be highly visible from surrounding properties and streets. Planning Commission Lands of Agana May 7, 2009 Page 2 Comments from neighbor Since the April 2"a, 2009 Planting Commission hearing, staff received an e-mail from Mr. and Mrs. Lauterbach (neighbors to the immediate south), who expressed concern over the long term health of oak trees on their property adjacent to the project site whose limbs were trimmed by the applicant (attachment 3). Staff recommends tree protection fencing mound the former driplines of these trees to avoid damage to their root systems by construction equipment (condition 17). CEOASTATUS The proposed Site Development Permit is categorically exempt from the provisions of the California Environmental Quality Act by provision of Section 15303(a). ATTACHMENTS 1. Recommended conditions of approval 2. Staff report to the Planning Commission with attachments, dated April 2, 2009 3. E-mail correspondence from Valerie Lauterbach, neighbor at 25712 Elena Road 4. Project plans, prepared by Stotler Design Group and Giuliani & Kull, Inc., dated April 10,2009 Planning Commission Lands of Again May 7, 2009 Page 3 ATTACHMENT RECOMMENDED CONDITIONS FOR A SITE DEVELOPMENT PERMIT FOR A NEW RESIDENCE WITH BASEMENT SECOND UNIT (CABANA), AND POOL LANDS OF AGAM, 25611 VINEDO LANE File 4315-08-ZP-SD-GD PLANNING DEPARTMENT 1. No other changes or modifications to the approved plan are allowed except as otherwise first reviewed and approved by the Planning Director or the Planning Commission, depending on the scope of the changes. 2. All existing Blue Gum (E. globulus), Pink Ironbark (E. sideroxylon rosea), River Red Gum (E. camaldulensis), Swamp Gum (E. rudis), Honey Gum (E. melliodora), or Manna Gum (E. viminalis) eucalyptus trees on the property located within 150' of any structures or roadways shall be removed prior to final inspection of the new residence. Removal of eucalyptus trees shall take place between the beginning of August and the end of January to avoid disturbance of nesting birds protected under the Federal Migratory Bird Treaty Act (MBTA) and California Department of Fish and Game Code Section 3500 et seq unless a nesting bird survey is fust conducted and there is a determination that there are no active nests within the tree. After completion of rough framing or at least six (6) months prior to scheduling a final inspection, the applicant shall submit landscape screening and erosion control plans for review by the Site Development Committee. The application for landscape screening and erosion control shall be accompanied by the applicable fee and deposit. The plans shall be reviewed at a noticed public hearing. Attention shall be given to plantings which will be adequate to break up the view of the new residence from surrounding properties and streets. All landscaping required for screening purposes and for erosion control (as determined by the City Engineer) must be installed prior to final inspection of the new residence. All lighting must comply with Town Policy. 4. A landscape maintenance deposit in the amount of $5,000 shall be posted prior to final inspection. An inspection of the landscape to ensure adequate establishment and maintenance shall be made two years after the installation. The deposit will be released at that time if the plantings remain viable. All new exterior lighting fixtures shall have frosted/etched glass enclosures or be shielded light fixtures. Seeded or bent glass is not acceptable. No lighting may be placed within setbacks except as shown on the approved plan. The applicant shall provide the Town with a lighting detail or manufacturer's specification on Planning Commission Lands of Again May 7, 2009 Page 4 the fixtures to be used, prior to acceptance of plans for building plan check. All lighting must comply with the Town's Lighting Policy prior to final inspection. 6. Prior to requesting the foundation inspection, a registered civil engineer or licensed land surveyor shall certify in writing and state that "the location of the residence and roof eaves comply with the location shown on the approved plans relative to the property lines." The elevation of the residence shall be similarly certified in writing to state that "the elevation of the residence matches the elevation and location shown on the approved plan." The applicant shall submit the stamped and signed letter(s) to the Planning Department prior to requesting a foundation inspection. 7. Prior to requesting the final framing inspection, a registered civil engineer or licensed land surveyor shall certify in writing and state that "the height of the'new residence complies with the 27' maximum structure height, measured as the vertical distance at any point from the bottom of the crawl space or basement ceiling if excavated below natural grade, to the highest part of the structure directly above (including roof materials)." The overall structure height shall be similarly certified in writing and state that "all points of the building (including chimneys and appurtenances) lie within a thirty-five (35 ) foot horizontal band based, measured from the lowest visible natural or finished grade topographical elevation of the structure along the building line and the highest topographical elevation of the roof of the structure." The applicant shall submit the stamped and signed letter(s) to the Planning Department prior to requesting a final framing inspection. 8. Standard swimming pool conditions: a. Lights shall be designed so that the source is not visible from off-site. b. Drainage outfall structures shall be constructed and located to the satisfaction of the City Engineer. c. Pool equipment shall be enclosed on all four sides with a roof for noise mitigation and screening. 9. For swimming pools, at least one of the following safety features shall be installed to the satisfaction of the Town Building Official: a. The pool shall be isolated from access to the residence by an enclosure (fencing). b. The pool shall be equipped with an approved safety pool cover. c. The residence shall be equipped with exit alarms on those doors providing direct access to the pool. d. All doors providing direct access from the home and second unit (cabana) to the swimming pool shall be equipped with a self-closing, self -latching device with a release mechanism placed no lower than 54 inches above the floor. Planning Commission Lands ofAgam May 7, 2009 Page 5 10. Skylights, if utilized, shall be designed and constructed to reduce emitted light. No lighting may be placed within skylight wells. 11. Air conditioning units shall be located a minimum of 40' from the front property line and 30' from the side and rear property lines. 12. Fire retardant roofing (class A) is required for all new construction. 13. No new fencing or gates are approved. Any new fencing or gates shall require review and approval by the Planning Department prior to installation. 14. The applicant shall pay any applicable School District (Los Altos or Palo Alto) fees prior to acceptance of plans for building plan check from Los Altos Hills. The applicant must take a copy of required fee payment forms that have been completed by the Town to both the elementary and high school district offices, pay the appropriate fees and provide the Town with a copy of their receipts. 15. At time of submittal of plans for building plan check, the applicant shall submit one of the following checklists to demonstrate compliance with the Town's Green Building Ordinance: A GreenPoint Rated checklist with the building permit application to indicate that the project will achieve a minimum of fifty (50) points. The checklist shall be completed by a qualified green building professional and shall be attached to the front of the construction plans. The construction plans shall include general notes or individual detail drawings, where feasible, showing the green building measure to be used to attain the required points. b. A LEED for Homes checklist with the building permit application to indicate that the project will achieve a minimum of forty-five (45) points or LEED certification. The checklist shall be completed by a qualified green building professional and shall be attached to the front of the construction plans. The construction plans shall include general notes or individual detail drawings, where feasible, showing the green building measure to be used to attain the required points. 16. Prior to final inspection and occupancy, a qualified green building professional shall provide documentation verifying that the building was constructed in compliance with GreenPoint Rated or LEED® certification. 17. Prior to beginning any grading or construction operation, all significant trees on the adjacent property to the south (Lands of Lauterbach) with drip lines that encroach onto the subject property are to be fenced at the original drip line. Planning Commission Lands of Again May 7, 2009 Page 6 Chain-link fencing shall clearly delineate the drip line on the subject property. Town staff must inspect the chain-link fencing and the trees to be fenced prior to commencement of grading. The property owner shall call for said inspection at least three days in advance of the inspection. The chain-link fencing must remain throughout the course of construction. No storage of equipment, vehicles or debris shall be allowed within the drip lines of these trees. ENGINEERING DEPARTMENT 18. As recommended by Cotton, Shires, & Associates, Inc., in their report dated January 9, 2009, the applicant shall comply with the following: a. Updated CBC Design Criteria: The applicant's geotechnical consultant should prepare updated 2007 CBC seismic parameters for utilization in preparation of final construction plans by the Project Structural Engineer. b. Geotechnical Plan Review: The applicant's geotechnical consultant shall review and approve all geotechnical aspects of the project building and grading plans (i.e., site preparation and grading, site drainage improvements and design parameters for foundations) to ensure that their recommendations have been properly incorporated. The consultant should specifically evaluate the proposed locations and design of subsurface drainage retention/percolation systems with respect to the geotechnical compatibility with other site improvements (including basement subdrain systems). Any appropriate design revisions from a geotechnical perspective should be recommended. Geotechnical Field Inspection: The geotechnical consultant shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections shall include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations and retaining walls prior to the placement of steel and concrete. The results of these inspections and the as -built conditions of the project shall be described by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to final inspection (granting of occupancy). The results of the CBC update and Geotechnical Plan review shall be summarized by the geotechnical consultant in a letter and submitted to the Town Engineer for review along with documents submitted for building permit plan check. 19. Peak discharge at 25611 Vinedo Lane, as a result of Site Development Permit 315-08, shall not exceed the existing pre -development peak discharge value of the property. Detention storage must be incorporated into the project to reduce the predicted peak discharge to the pre -development value. Provide the data and peak Planning Commission Lands ofAgam May 7, 2009 Page 7 discharge hydrologic model(s) utilized, as well as, the calculations of the peak discharge value prior and post development. Determine the design peak runoff rate for a 10 -year return period storm and provide detention storage design plans to reduce the predicted peak discharge to the pre -development value. All documentation, calculations, and detention storage design (2 plan copies) shall be submitted for review and approval to the satisfaction of the City Engineer prior to acceptance of plans for building plan check. Prior to final inspection, a letter shall be submitted from the project engineer stating that the site grading and storm drainage detention system were constructed as shown on the approved plans and in accordance with their recommendations. 20. Any, and all, changes to the approved grading and drainage plan shall be submitted as revisions from the project engineer and shall first be approved by the Town Engineering Department. No grading shall take place during the grading moratorium (October 15 to April 15) except with prior approval from the City Engineer. No grading shall take place within ten feet of any property line except to allow for the construction of the driveway access. 21. All public utility services serving this property shall be placed underground. The applicant should contact PG&E immediately after issuance of building permit to start the application process for undergrounding utilities which can take up to 66=8 months." 22. Two copies of an erosion and sediment control plan shall be submitted for review and approval by the Engineering Department prior to acceptance of plans for building plan check. The contractor and the property owner shall comply with all appropriate requirements of the Town's NPDES permit relative to grading and erosion/sediment control. The first 100 feet of the driveway shall be rocked during construction and all cut and fill slopes shall be protected from erosion. All areas on the site that have the native soil disturbed shall be protected for erosion control during the rainy season and shall be replanted prior to final inspection. 23. Two copies of a grading and construction operation plan shall be submitted by the property owner for review and approval by the City Engineer and Planning Director prior to acceptance of plans for building plan check The grading/construction operation plan shall address truck traffic issues regarding dust, noise, and vehicular and pedestrian traffic safety on Vinedo Lane and Elena Road, storage of construction materials, placement of sanitary facilities, parking for construction vehicles, clean-up area, and puking for construction personnel. A debris box (trash dumpster) shall be placed on site for collection of construction debris. Arrangements must be made with the Green Waste Recovery, Inc. for the debris box, since they have a franchise with the Town and no other hauler is allowed within the Town limits. Planning Commission Lands of Agam May 7, 2009 Page 8 24. The property owner shall inform the Town of any damage and shall repair any damage caused by the construction of the project to pathways, private driveways, and public and private roadways, prior to final inspection and release of occupancy permits and shall provide the Town with photographs of the existing conditions of the roadways and pathways prior to acceptance of plans for building plan check 25. The driveway shall be required to be fully constructed and to be roughened where the pathway intersects, to the satisfaction of the City Engineer, prior to final inspection. 26. The property owner shall be required to connect to the public sanitary sewer prior to final inspection. A sewer hook up permit shall be required by the Town's Public Works Department prior to submittal of plans for building plan check An encroachment permit shall be required for all work proposed within the public right of way prior to start work. 27. The property owner shall pay a pathway fee of $50.00 per linear foot of the average width of the property prior to acceptance of plans for building plan check FIRE DEPARTMENT 28. Provide an approved fire department engine driveway turnaround with a minimum radius of 36 feet outside and 23 feet inside. Installations shall conform with Fire Department Standard Details and Specifications D-1. The proposed Grasscrete must be installed and maintained to the satisfaction of the Fire Department and per manufacturers' instructions. The Grasscrete surface must provide all-weather performance equal to asphalt or concrete and must support the imposed loads of fire apparatus. Written certification that this installation will provide sufficient load-bearing capabilities and all-weather durability must be prepared by a licensed engineer and submitted with plans for building permit plan check. 29. Provide an access driveway with a paved all weather surface, a minimum unobstructed width of 14 feet, a vertical clearance of 13 feet 6 inches, and a minimum circulating turning radius of 36 feet outside and 23 feet inside, and a maximum slope of 15%. 30. An automatic residential fire sprinkler system approved by the Santa Clara County Fire Department shall be included in all portions of the building. Three sets of plans prepared by a sprinkler contractor shall be submitted to the Santa Clara County Fire Department (14700 Winchester Blvd., Los Gatos, CA 95032) for review and approval. The sprinklers shall be inspected and approved by the Fire Department, prior to final inspection and occupancy of the new residence. Planning Commission Lands of Again May 7, 2009 Page 9 31. The project is located within the designated Wildland-Urban Interface Fire Area. The building construction shall comply with the provisions of California Building Code (CBC) Chapter 7A. Note that vegetation clearance shall be in compliance with CBC Section 701A.3.2.4 prior to final approval. Check with the Planning Department for related landscape plan requirements. 32. Approved numbers or addresses shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Numbers shall contrast with their background. CONDITION NUMBERS 14, 19, 22, 23, 24, 26 AND 27 SHALL BE COMPLETED AND SIGNED OFF BY TOWN STAFF PRIOR TO ACCEPTANCE OF CONSTRUCTION PLANS FOR PLAN CHECK BY THE BUILDING DEPARTMENT. Project approval may be appealed if done so in writing within 22 days of the date of this notice. The building permit cannot be issued until the appeal period has lapsed. The applicant may submit construction plans to the Building Department after ]une 1, 2009 provided the applicant has completed all conditions of approval required prior to acceptance of plans for building plan check. Upon completion of the construction, a final inspection shall be required to be set with the Planning and Engineering Departments two weeks prior to final building inspection approval. NOTE: The Site Development permit is valid for one year from the approval date (until May 7, 2010). All required building permits must be obtained within that year and work on items not requiring a building permit shall be commenced within one year and completed within two yews. Attachment 2 TOWN OF LOS ALTOS HILLS April 2, 2009 Staff Report to the Planning Commission RE: SITE DEVELOPMENT PERMIT FOR A TWO STORY NEW RESIDENCE WITH A BASEMENT, SECONDARY UNIT (CABANA), AND SWRvflvIING POOL; LANDS OF AGAM, 25611 VINEDO LANE (LOT # 3); FILE #315-08-ZP- SD-GD. FROM: David Keyon, Associate Planner W APPROVED BY: Debbie Pedro, AICP, Planning Directorc� RECOMMENDATION: That the Planning Commission: Approve the requested Site Development Permit subject to the recommended conditions of approval in Attachment 1. BACKGROUND The subject property is Lot # 3 of a 3 Lot Subdivision application approved on Much 13, 2008 by the City Council (application 148 -07 -IS -ND -TM). No structures currently exist on site. CODE REOUlRFMENTS This application is not eligible for the Fast -Track process under section 10- 2.1305.1(a)(3), as the applicant requests a Grading Policy exception for the driveway and subterranean garage. The Zoning and Site Development sections of the Municipal Code are used to evaluate proposed projects including floor and development area limitations, grading, drainage, height, setbacks, visibility, and parking requirements. DISCUSSION Site Data: Gross Lot Area: 1.070 acres Net Lot Area: 1.066 acres Average Slope: 12.9% Lot Unit Factor. 1.000 Floor Area and Development Area (in square feet) Maximum Proposed Existing Increase Remaining Development Area 13,913 12,682 0 12,682 1,231 Floor Area 5,855 5,712 0 5,712 143 Basement n/a (3,577) 0 (3,577) n/a Shoff Report to the Planning Commission Lands of Agam April 2, 2009 Page 2 Site and Architecture The site is accessed via a 35' wide driveway easement across 25631 Vinedo Lane (Lot l) to Vinedo Lane, a private road. The site is bounded by orchards to the north, a vacant parcel to the west (Lot 2), and properties with existing residences to the east and south. The owner proposes to construct a two-story house with a basement and subterranean garage, swimming pool, and detached second unit (cabana). The house is proposed to be 5,461 square feet with a 3,577 square foot basement. The maximum height will be 27', with a maximum overall height (including chimneys and appurtenances) of 34'10". The new residence and second unit (cabana) will be located at least 100 feet from the southern (side) property line, 32 feet from west (side) property line, 32 feet from the rear (north) property line, and 96 feet to the east (side) property line. The proposed basement encompasses a garage and au -pair living area. The basement is entirely below grade except for a daylighted portion at the three -car garage. A detached second unit with a bedroom, full bathroom, and kitchen is proposed at the rear of the property (labeled "cabana" on the floor plan). This second unit complies with Section 10-1.702(1) of the Town's Municipal Code, as it will be subordinate to the primary dwelling on site, the property is over 1 acre in size, and is only 251 square feet in size. Due to the small size of the second unit and its location at the rear of the property, the structure will not be visually prominent. Driveway & Parkins Access is proposed from Vinedo Lane via a shared driveway with Lot 2. The driveway is proposed tosplit into two; one 14' wide driveway up the west side of the house to a two - car garage on the 1" floor, and one 12' wide driveway along the front of the house leading to a subterranean three -car garage. Five (5) parking spaces will be provided, four for the main house and one for the second unit (pool cabana) as required by Town Code. All five will be located within either the 2 - car garage on the main level or the 3 -car basement garage. Outdoor Lighting The applicant proposes ceiling -mounted downlights for the entry area, covered patio, and second story covered balcony, and wall -mounted fixtures at the entry doors (see the outdoor lighting plan on sheets El -E3). All light fixtures must be shielded or incorporate frosted or etched glass to ensure that the light source is not visible from off site (condition 45). Landscape lighting will be reviewed with the landscape screening application required prior to building permit final (Condition #3). Staff Report to the Planning Commission Lands ofAgam April 2, 2009 Page 3 Trees and Landscapin One 18" oak tree is proposed for removal at the entrance to the property to accommodate the driveway. Two (2) 36" box oak trees must be planted on site to replace the removed oak tree (Condition #3). Thirteen (13) other trees are proposed to be removed on site, including a cluster of cedars and pines at the location of the proposed residence. A landscape screening and erosion control plan will be required after completion of framing for the new residence to ensure that the visual effects of the development will be mitigated. This plan will be reviewed at a noticed public hearing before the Site Development Authority, and all required vegetation for screening purposes must be planted prior to final inspection. A landscape maintenance deposit will be required to ensure the long term viability of screening vegetation (condition 44). Grading Policy Exception Total grading quantities include 4,825 cubic yards of cut (basement, cabana, driveway and swimming pool) to be exported off site. The Engineering Department has reviewed the proposed grading and concluded that it is not in conformance with the Town's grading policy. Specifically, the applicant is requesting a grading policy exception for up to 11 feet of cut (where 8' is allowed) for the driveway leading to the basement garage. If the proposed grading were to occur on a hillside or ridgeline property, the excavation for the driveway and basement garage would result in massive retaining walls that are highly visible and substantial visual alteration of the natural terrain in violation of Section 10-2.702.c of the Site Development Code. However, in this case, the lot is relatively flat and the proposed grading will help lower the profile of the new home. Furthermore, the driveway retaining walls will be below natural grade and will not be highly visible from surrounding properties and streets. In the past five (5) yews, the Planning Commission has granted Grading Policy Exceptions for basement driveways exceeding 8' of cut for the following projects: • Lands of Khang, 26750 Robleda Court, SDP 4242-08-ZP-SD-GD, March 5, 2009 • Lands of Ascension Development, 26491 Ascension Drive, SDP #252-07-ZP-SD- GD, June 5, 2008 • Lands of Corrigan, 13920 Fremont Pines Lane, SDP #7-06-ZP-SD-GD, April 6, 2006 The Grading Policy allows the Planning Commission the discretion to approve grade differentials beyond standard requirements when the individual site dictates the need to deviate from the criteria. If the Planning Commission decides to approve the project as proposed, findings for approval of the Grading Policy Exception should be cited. (Attachment 2) Staff Report to the Planting Conunission Lands of Agan April 2, 2009 Page 4 Drainage The proposed drainage system consists of an on-site retention system to maintain pre - development runoff levels. Engineering staff reviewed the proposed system and approved the conceptual design pursuant to Section 10-2.503 of the Municipal Code. The final drainage plan must be approved by the City Engineer prior to acceptance of plans for building permit review (condition #18). Green Building Ordinance The proposed new house is required to comply with the Town's Green Building Ordinance. This ordinance requires all new residences to achieve a minimum of fifty (50) points on Built It Green's Green Point Rated checklist or forty-five (45) points on LEED for Home's checklist. The applicant submitted a GreenPoint Rated checklist indicating that the project is designed to achieve a total of 82 points, in excess of the 50 required by Code. Fire Department Review The Santa Clara County Fire Department reviewed the plans and requires an on-site fire engine turnaround area (Condition #27). Certification from a licensed engineer must be submitted with the building permit plans confirming that the proposed grasscrete in the driveway and turnaround area will provide all-weather performance equal to asphalt or concrete and can support the required loads of fire engines (Condition 27). Committee Review The Pathways Committee reviewed the project and recommends a pathways in -lieu fee (Condition 26). The Environmental Design and Protection Committee commented on the GreenPoint checklist, the tree removal, the secondary dwelling unit and siting of the house, CEOA STATUS The proposed new residence is categorically exempt from the provisions of the California Environmental Quality Act per Section 15303(a) and (e). Staff Report to the Planning Commission Lands of Agam April 2, 2009 Page 5 ATTACHMENTS 1. Recommended conditions of approval 2. Findings for Approval of the Grading Policy Exception 3. Recommendations from Santa Clara County Fire Department, dated 12/15/08. 4. Recommendations from Cotton, Shires, and Associates, dated 1/9/09. 5. Recommnendations from Environmental Design Committee, dated 12/15/08. 6. Worksheet #2 (NUA and MDA calculations) 7. Letter from Giuliani & Kull, Inc., Project Engineers and Surveyors, dated 3/20/09. 8. Development plans: site, topographic, grading & drainage, floor, elevation, section, roof, and lighting plans Staff Report to the Planning Commission Lands of Again April 2, 2009 Page 13 ATTACHMENT RECOMMENDED FINDINGS FOR GRADING POLICY EXCEPTION LANDS OF AGAM, 25611 VINEDO LANE File 4 315-08-ZP-SD-GD 1. The proposed grading is consistent with Section 10-2.702.c of the Los Altos Hills Municipal Code, the proposed grading will help lower the profile of a portion of the structure and render it less visible from off-site. 2. The proposed area of grading will not result in the substantial visual alteration of the natural terrain. The property's existing contours and basic landform are retained. 3. The proposed grading will not result in the placement of retaining walls that are visible from off-site. 4. The Grading Policy emphasizes cut to lower the profile of structures over fill or foundation walls, which tend to raise the profile of the structure. The proposed underground garage requires no fill. �P° 000 FIRc DEPARTMENT SANTA CLARA COUNTY 14700 Winchester Blvd., Los Gatos, CA 95032-1818.::.,w'd (408) 378-4010 • (408) 378-9342 (fax) AmmItm As•m REVIEW 06 3516 ND. — PLAN REVIEW COMMENTS PENMRP CMMEC. I $NEST No REDVIREMENT Plan review of a 9,290 square foot two-story single-family residence with two attached garages, basement, covered patio and cabana. CFc SEC 1 Rice uired Fire Flow: The fire flow for this project is 1,500 gpm at 20 psi residual Appendix 8 B ppressure. The adjusted fire flow is available from area water mains and fire hydrants) which are spaced at the required spacing. 2 Wildland-Urban Interface: This project is located within the designated Wildland-Urban Interface Fire Area. The building construction shall comply with the provisions of California Building Code (CBC) Chapter 7A. Note that vegetation clearance shall be in compliance with CBC Section 701A.3.2.4 prior to final approval. Check with the Planning Department for related landscape plan requirements. CFC Sec. 3 Fire Sprinklers Required: Approved automatic sprinklers are required in all new 903.2, as and existing modified buildings when gross floor area exceeds 3,600 square feet or adopted that are 3 or more stories in height. Exception:One-time additions to existing and en eA buildings made after 01 / 01 / 2008 that do not exceed 500 gross square feet. An automatic sprinkler shall be provided in all new structures located in the designated Wildland-Urban Interface area. Exception: Any non -habitable accessory structures to single family residences that have gross floor area of 500 square feet or less. A State of California licensed (C-16) Fire Protection Contractor shall submit plans, calculations, a completed permit application and appropriate fees to this department for review and approval prior to beginning their work. CFC Sec. 503 4 Fire Apparatus (Eneine)Access Driveway Required: Provide an access driveway with a paved all weather surface, a minimum unobstructed width of 14 feet, vertical clearance of 13 feet 6 inches, minimum circulating turning radius of 36 feet outside and 23 feet inside, and a maximum slope of 15%D. Installations shall CM RANG SPECS NEW RMDL AS DCCLPANCY CONST. TTPE Apla"MNDm DATE PAGE LAH N ❑ ® ❑ ❑ R-3, U V -B Stotler Design Group 12/15/2008 1 oP 2 SECIFLODR ARFA LOAD DEGCRIPTIDN RY LOT 3, 2 story 9290 sf Residential Construction Harding, Doug N4ME DF PROJECT LOCATION SFR 25611 Vinedo Ln Organized as the Santa Clara County Central Fire Protection District Serinng Los Aft. Hill ,, Los Ga..,onte Stnono, Morgan Hill, and Soratog s Altos, DDMEC. I SHEET I NO. I REOVWEMEM C Sec. C Sec. EIRr, DEPARTMENT SANTA CLARA COUNTY 14700 Winchester Blvd., Los Gatos, CA 95032-1818 (408) 378-4010 • (408) 378-9342 (fad • uunv.scafd.o s Ap PUN REVIY+o 08 3516 PLAN REVIEW COMMENTS PERYRNc to Fire Department Standard Details and Specifications sheet D-1. rire me "'Attngmel Unvewav'Turn-around Required: Provide an approved fire department engine driveway turnaround with a minimum radius of 36 feet outside and 23 feet inside. Installations shall conform with Fire Department Standard Details and Specifications D-1. NOTE: Plans show 'Grasscrete' as the surface of the Fire Dept. turnaround. This Droduct must be installed and maintained to the satisfaction of this department and )er manufacturers instructions. The Grasscrete surface must be provide ill -weather performance equal to asphalt or concrete and must support he imposed loads of fire apparatrus. Written certification that this installation will )rovide sufficient load-bearing capabilities and all-weather durability must be )rovided to this office by a properly licensed engineer. uses ldentitication: Approved numbers or addresses shall be placed on all and existing buildings in such a position as to be plainly visible and le ble the street or road fronting the property. Numbers shall contrast with their ns not approved. not issue Building Permit. CYy PIANS SPECS NEW AMM " OCCUPANCY CONST. TYPE peps-.— ppTE AH ® ❑ N ❑ ❑ R-3, U V -B Stotler Design Group ppGE 12/15/2008 2 2 CJFLppR APFA LOAD DESCFIPrbH —OF_ >T 3, 2 story 9290 sf Residential Construction SY Harding, Doug AYE OF PIX)JECT LOCATION SFR 25611 Vinedo Ln Organized as the O_- Clara County Central fire Protection District Seming Santa Clam County and the comm nitlez o)Camp6ell, Cupertino, Ins Altos, Los Altos Hills, Los Gatos, Monte Sereno, Morgan Hill, and SDmtoaa 0 COTTON, SHIRES & ASSOCIATES, INC. CONSULTING ENGINEERS AND GEOLOGISTS January 9, 2009 L0388 TO: Debbie Pedro Planning Director TOWN OF LOS ALTOS HILLS 26379 Fremont Road Los Altos Hills, CA 94022 SUBJECT: Geotechnical Peer Review RE: Agam, New Residence 315-08-ZP-SD-GD 25611 Vinedo Lane At your request, we have completed a geotechnical peer review of the subject application for the proposed new residence using: Geotechnical Investigation (report) prepared by JF Consulting, Inc., dated July 11, 2007; - Architectural Plans (13 sheets, various scales) prepared by Stotler Design Group, dated March 20, 2008; and Civil Plans (4 sheets, various scales) prepared by NNR Engineering, dated December 4, 2008. In addition, we have reviewed pertinent technical documents from our office files, including a previous subdivision plan including the subject property in 2007 (L0227), and completed a recent site inspection. DISCUSSION Based on our review of the referenced plans, we understand that the applicant proposes to construct a new two-story, single-family residence with basement on one of Nonbem Calif -mi- Office 33o Village Lane Los Gatos, CA 95030-7218 (408) 3545542 • Fax (408) 354182 e-mail losgatoAcottonshires.com www.cottonshires.com eenteal eablamta umea 6417 Dogtown Road San Andreas, GA 95249-9640 (209) 7364252 • Fax (209) 7361212 e-mail: cottonAwes®starband.net Debbie Pedro January 9, 2009 Page 2 L0388 the three recently subdivided lots. At the time of our recent site inspection, the lot was covered with grass, and mature trees. Access to the lot is to be provided via a new asphalt driveway extending from Vinedo Lane. Proposed project grading includes approximately 4,825 cubic yards of cut to be exported from the site. This volume includes excavation for the basement and a swimming pool. The project includes a stone water retention system, bubbler boxes, and dissipater structures. SITE CONDITIONS The subject property is generally characterized by gentle (5 to 10 percent "cli,at,m) southeast -facing hillside topography. Drainage at the site is ch ractenzed as uncontrolled sheet flow to the east and southeast. According to the Town Geologic Map, the subject property is underlain, at depth, by weathered greenstone bedrock of the Franciscan Complex. According to exploratory borings presented in the referenced investigation, greenstone bedrock materials are locally overlain by relatively shallow, potentially expansive sandy clay (colluvium) in the vicinity of the proposed building pad. According to the Town Geotechnical Hazards Map, the site lies partially within "A" and "D" geotechnical zones. The nearest traces of the potentially active Monta Vista and Berrocal faults are mapped approximately 600 feet northwest and 1,150 feet southwest, respectively, of the subject property. Additionally, the active San Andreas fault is located approximately 3.1 miles southwest of the site. CONCLUSIONS AND RECOMMENDED ACTION Site development is constrained by anticipated strong seismic ground shaking, and potentially expansive earth materia&. 'Ihe Project Geo`.echrucal Consultant has previously conducted an investigation of the entire subdivision and provided geotechnical design recommendations that generally appear appropriate for apparent constraints to the currently proposed development. We note that presented seismic design parameters were based on the 1997 UBC. Updated 2007 California Building Code (CBC) seismic design parameters should be prepared. The design of project drainage systems should be evaluated from a geotechnical perspective by JF Consulting. We do not have geotechnical objections to the proposed layout of site improvements. We recommend that documentation to address the following Items 1 and 2 be submitted to the Town along with other documents for building permit plan -check. COTTON, SHIRES & ASSOCIATES, INC. Debbie Pedro Page 3 January 9, 2009 L0388 1. Updated CBC Design criteria - The applicant's geotechnical consultant should prepare updated 2007 CBC seismic parameters for utilization in preparation of final construction plans by the Project Structural Engineer. 2. Geotechnical Plan Review - The applicant's geotechnical consultant shall review and approve all geotechnical aspects of the project building and grading plans (i.e., site preparation and grading, site drainage improvements and design parameters for foundations) to ensure that their recommendations have been properly incorporated. The consultant should specifically evaluate the proposed locations and design of subsurface drainage retentionlpercoiation systems with respect to geotechnical compatibility with other site improvements (including basement subdrain systems). Any appropriate design revisions from a geotechnical perspective should be recommended. The results of the CBC update and geotechnical plan review should be summarized by the geotechnical consultant in a letter and submitted to the Town along with other documents for building permit plan -check. 3. Geotechnical Field Inspection -The geotechnical consultant shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections should include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations and retaining walls prior to the placement of steel and concrete. The results of these inspections and the m -built conditions of the .project should be described by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to final (granting of occupancy) project approval. LIMITATIONS This geotechnical peer review has been performed toprovide technical advice to assist the Town with discretionary permit decisions. Our services have been limited to review of the documents previously identified, and a visual review of the property. Our opinions and conclusions are made in accordance with generally accepted principles COTTON, SHIRES & ASSOCIATES, INC. Debbie Pedro Page January 9, 2009 L0388 and practices of the geotechnical profession. This warranty is in lieu of all other warranties, either expressed or implied. TS:DTS:JS:kd Respectfully submitted, COTTON, SHIRES AND ASSOCIATES, INC. TOWN GEOTECHNICAL CONSULTANT Ted Principal Engineering Geologist CEG 1795 David T. Schrier Principal Geotechnical Engineer GE 2334 COTTON, SHIRES & ASSOCIATES, INC. �1 L, Lt Environmental —esign and Protection Committee New Residence/Remodel Evaluation Reviewedby: � �'ti'�eEy Date tr ILS RECEIVED Applicant �^ OEC 1 5 toes Name YT� h'L I um OF LOS ALTOS IULL$ Address KyLf (1)(3 Site issues/comments: DOWN OF LOS ALTOS HILL PLANNING DEPARTMENT 26379 Fremont Road • Los Altos Hills, California 94022 • (650) 941-7222 •FAX (650) 941-3160 WORKSHEET #2 TOWN OF LOS ALTOS HILLS EXISTING AND PROPOSED DEVELOPMENT AREA AND FLOOR AREA PROPERTY OWNER'S NAME Isaac Again PROPERTY ADDRESS 25611 Vinedo Lane, Los Altos Hills, Ca CALCULATED BY SCOTT STOTLER DATE December 10 2008 1. DEVELOPMENT AREA Existing (to be Proposed Total 1974 (SQUARE FOOTAGE) removed) (Additions/Deletions) 0 A. House and Garage (from Pan 3. A.) 0 5411 5411 B. Porch (Non -MFA) 0 50 50 C. Driveway and Parking (Measured 100' along centerline) 0 3485 3485 D. Patios/Walkways/egress/lightwells 0 2952 2952 E. Cabana 0 0 0 F. Pool and Decking 0 533 533 G. Accessory Buildings (from Pan B) 0 251 251 H. Any other coverage (Terraces) 0 TOTALS 0 12682 12682 Maximum Development Area Allowed - NIDA (from Worksheet #1) 13913 2. TOTAL IMPERVIOUS SURFACE Existing Proposed Total (SQUARE FOOTAGE) TOTALS 0 3. FLOOR AREA (SQUARE FOOTAGE) Existing A. House and Garage a. 1st Floor b. 2nd Floor c. Attic and Basement (Non -MFA) d. Garage e. Porch (MFA) B. Accessory Buildings 11670 Proposed (Additions/Deletions) 11670 Total 0 3000 3000 0 1974 1974 0 0 0 0 437 437 o so so a- 1st Floor 0 b. 2nd Floor 0 c. Attic and Basement 0 TOTALS 0 Maximum Floor Area Allowed -MFA (from Worksheet # 1) 251 251 0 0 0 0 5712 5712 5855 TOWN USE ONLY CHECKED BY DALE Rev. 3/20/02 Page 1 of I Town of Los Altos Hills r' Giuliani & Kull, Inc. San Jose - Oakdale - Auburn March 20, 2009 Project No. 07172 Nicole Horvitz David Keyon Planning Dept. Town of Los Altos Hills 26379 Fremont Road Los Altos Hills, CA 94022 Subiect: 25631 Elena Road (Lot 1) & 25611 Elena Road (Lot 31 Dear Nicole and David: This letter is to state that Giuliani and Kull, Inc. has reviewed the story poles constructed on both of the subject sites. We found that the poles have been constructed, both horizontally and vertically, in general conformance with the construction stakes that we provided, as well as the architectural plans prepared by Stotler Design Group, and the grading plans prepared by NNR Engineering. If you have any questions or comments regarding this matter, please do not hesitate to contact our office. Sincerely, GIULIANI & KULL, INC. tjl a:t t , VVMark A. Helton, PE, PLSJ 4880 Stevens Creek Blvd., Suite 205 • San Jose, CA 95129 - (408) 615-4000 • Fox (408) 615-4004 Attachment 3 David Kevon From: Valerie Lauterbach [ Sent: Sunday, April 05, 2009 10:28 PM To: Carl Cahill Cc: David Keyon Subject: Deliberate damage to heritage oaks Dear Mr. Cahill, we have a line of heritage oaks (with a circumference of 36" or more at the 4' high point) with trunks just inside the perimeter of our property, 25712 Elena Road, adjacent to Lot 3 of 25611 Vinedo Lane. While taking a close look at the story poles for the proposed residence for Lot 3, we discovered that the owner had cut off all of the branches of these oaks that extended over his property. Had the branches not been cut, he would have had to fence off half -circles extending 20 feet onto his property to protect the dripline. Of course, the dripline is still there, even though he cut the branches, and needs to be protected from grading and other damage. Instead he has plans for a driveway only ten feet from the property line. It seems clear that the trimming was done to deliberately make that land available for grading, because another heritage oak just beyond the trimmed ones, and beyond his development plans, wasn't touched. We are concerned for the health of these trees if he is allowed to pretend that they atop abruptly at the property line as he has trimmed them, as well as being concerned about the development process with this owner! I'm addressing this email to you, since I see from the website that your responsibilities include "responsibility and authority to ensure that the laws and ordinances of the Town are duly enforced," and I believe the heritage oaks are protected by a Town ordinance. I have some photos of the trimmed trees I could bring by your office. I will call your office tomorrow morning to discuss this situation. Thank you, Valerie Lauterbach