Loading...
HomeMy WebLinkAbout3.1Item 3.1 TOWN OF LOS ALTOS HILLS May 5, 2011 Staff Report to the Planning Commission SUBJECT: SITE DEVELOPMENT PERMIT FOR A NEW 5,147 SQUARE FOOT TWO STORY RESIDENCE WITH., A 4,916 SQUARE FOOT BASEMENT, AND A 780 SQUARE FOOT SWIMMING POOL THE PROPOSAL INCLUDES REMOVAL OF ONE 12" HERITAGE OAK TREE AND A REQUEST FOR A GRADING POLICY EXCEPTION FOR A DRIVEWAY AND YARD AREA ADJACENT TO A DAYLIGHTED BASEMENT; LANDS OF THRUN; 13818 PAGE MILL ROAD; FILE #257-10-ZP-SD-GD. FROM: Brian Froelich, AICP, Associate Planner 15 APPROVED: Debbie Pedro, AICP, Planning Director; RECOMMENDATION: That the Planning Commission: Approve the requested Site Development Permit and Grading Policy Exception for the new residence and swimming pool, citing the findings in Attachment #2 and subject to the conditions of approval in Attachment #1. BACKGROUND The subject property is located on the south side of Moon Lane. The property has a net size of 9.256 acres and an average slope of 31%. The topography of the site slopes up toward the center from all sides where the existing residence and secondary unit are sited on a knoll. The property is developed with a single family residence, a secondary dwelling unit, and a swimming pool. The secondary dwelling unit was approved by the Planning Commission in 1988 with a Variance for the size of the unit to exceed 1;000 square feet. The existing driveway is steep with sections where the slope is nearly 30%. The site is accessed from Moon Lane while maintaining a Page Mill Road address. Moon Lane is a private road. The applicant requests a Grading Policy exception for additional cut with a maximum depth of 12 feet for the driveway and yard areas adjacent to the basement garage. Driveways adjacent to garages that are cut into a slope are permitted a maximum of eight (8) feet of cut per the Town's Grading Policy where yard areas are allowed four (4) feet of cut. The applicant requests approval to remove one (12") heritage oak tree to accommodate the driveway grading. Planning Commission Lands of Thrun May 5, 2011 Page 2 CODE REQUIREMENTS This application is not eligible for the Fast -Track process per section 10-2.1305.1(a) (3), because the applicant requests a Grading Policy Exception. The Planning Commission has authority to allow Grading Policy Exceptions on individual projects. DISCUSSION Site Data: Gross Lot Area: Net Lot Area: Average Slope: Lot Unit Factor: Area Maximum Development 38,183 Floor 25,455 Site and Architecture 9:256 acres 9.256 acres 31% 5.091 Proposed Existing Increase Left 25,870 20,293 5,577 12,313 7,983 7,778 205 17,472 The 9.256 acre site has a 31 % slope that ascends from all sides to a knoll at the building site. The proposed residence and existing accessory buildings utilize 34% of the allowable floor area and 54% of the allowable development area. The proposed site layout includes a one story circular dwelling, basement with garage below the residence, driveway, decking and swimming pool. The exterior building materials include glass panels and painted steel. The design incorporates a pyramid shaped skylight and a roof deck. A portion (121 square feet) of the skylight exceeds 17 feet interior height and is counted twice for floor area purposes. The circular building design is centered on the existing residence, detached garage, and swimming pool sites. The top of the pyramid skylight is 24' 9" tall while the remainder of the building measures 14 feet above adjoining grade. The maximum proposed overall structure height is 34'9". The proposed residence complies with floor area, development area, setbacks, and height standards per Title 10 of the Municipal Code. Architectural style is not specifically regulated by the Town's Municipal Code. The project Architect intends to discuss the design and materials further at the public hearing. Driveway & Parking The proposed driveway will enter from Moon Lane in primarily the same location as the existing driveway. The existing driveway has a section where slope is nearly 30%. The Fire Department's maximum allowable driveway slope is 15% but exceptions can be Planning Commission Lands of Thrun May 5, 2011 Page 3 made for difficult sites up to 20% slope, which is achieved by the proposed driveway. The existing driveway ascends approximately 75 feet of elevation from Moon Lane where the proposed driveway ascends approximately 63 feet from Moon Lane. Cutting the driveway terminus area allows the driveway to meet the Fire Department's 20% standard but necessitates a Grading Policy Exception. Outdoor Lighting Building mounted lighting will be shielded downlights per plans sheet A0.02 (written description). Minimum required light will be utilized with two (2) fixtures per double door exit, one (1) fixture per single door exits and at stairways. The standard lighting Condition #7 for outdoor lighting, requires that fixtures be down shielded or have frosted/etched globes. The applicant will submit outdoor landscape lighting details with the required landscape screening plan. Grading The Engineering Department has reviewed the plans and has determined that the proposal does not comply with the Grading Policy but has forwarded conditions of approval if the Planning Commission approves the project. Grading quantities include: • 4,600 cubic yards of cut • 600 cubic yards of fill • 4,000 cubic yards export The proposed Grading Policy Exception includes the following two areas: • 12 foot cut for the driveway adjacent to basement .garage where 8 foot cut is the maximum allowed -The cut depth accommodates the vehicular access to the basement level. The 12 foot cut also lowers the driveway terminus elevation allowing the overall driveway way slope to be reduced from approximately 30% to 20%, which is the maximum exception allowed by the Santa Clara County Fire Department. These areas cover approximately 4,295 square feet. • 12 feet cut for yard areas adjacent to the driveway where 4 foot cut is the maximum allowed -Two yard areas flanking the driveway include additional cut depths. Grading these areas would reduce the amount of retaining walls on site and aesthetically allow the upper portion of the driveway an "open feel" as opposed to being a channel with retaining walls on both sides leading to the basement garage. These areas cover approximately 2,874 square feet. The additional cut allows the building to be lowered, which is "generally preferred" per the Grading Policy. The design reduces the visible bulk of the building from offsite particularly because the building site is at a higher elevation than the immediate offsite Planning Commission Lands of Thrun May 5, 2011 Page 4 vantage points. The additional cut allows the slope to meet the maximum Fire Department standard driveway slope. The Architect has prepared exhibits that detail offsite sight lines and views toward the proposed residence (plan sheet A2.04). Drainage The drainage design is primarily sheet flow away from the residence and surrounding hardscape improvements. Driveway drainage flowing back toward Moon Lane is directed into a lateral PVC pipe and conveyed into an energy dissipater and grassy swale to allow it to percolate on site. The net increase of coverage surfaces equals 1,868 square feet with the proposed project. Geotechnical Review The applicant's geotechnical consultants, Murray Engineers have prepared a Geotechnical Investigation Report. The report identifies areas of fill and several landslide areas in and around the subject site. The landslides are at the sides of the site and not at the knoll top where the proposed building site is located. Cotton and Shires Associates has recommended standard project conditions (Attachment #4) requiring the Geotechnical consultant to document their review of the construction documents and document their inspections (Conditions #19 a & b). Trees & Landscaping. The site contains a blend of natural and planned landscaping that includes 58 trees that are primarily grouped around the perimeter of the existing building site. The site has 22 heritage oak trees. Several acres of the property are void of trees. The applicant has retained the services of an Arborist, Ian Geddes and Associates (reports on plan sheet A2.07). The public notice conveyed information that four (4) heritage ,oak trees were to be removed, which the Civil Engineering plans had originally shown. The project Arborist has provided an updated report (April 26, 2011) stating that only one (1) heritage oak tree near the driveway needs to be removed and that the others can be protected during construction. The three (3) heritage oak trees in question are smaller varieties ranging from 12"-15" and are located near the rear yard retaining wall. Typical mitigation is 3:1 for removal. Town staff is recommending that the project conditions require mitigation plantings for the anticipated removal of four (4) trees at this time (Condition #18). At the conclusion of the project and at the applicant's request, the Town Arborist can review the health of the subject trees and reduce the required mitigation plantings as necessary. Planning Commission Lands of Thrun May 5, 2011 Page 5 Green Building, Ordinance The applicant has submitted a GreenPoint checklist in compliance with the Town's Green Building Ordinance. The building is designed to achieve 127 points in the GreenPoint Rated certification program. (Plans sheet A0.02) Fire Department Review The Santa Clara County Fire Department reviewed the plans and has required that the building be sprinklered and that the driveway accommodate a standard Fire Truck Turnaround. The site plan shows the location of a conforming Fire Truck Turnaround. Sanitation The site will be connected to the Los Altos basin sewer via extension of the existing main line located under Moon Lane. The project will necessitate extending the main line several hundred feet and bringing a private lateral onto the property. Town Committee's Review The Pathways Committee has recommended unanimously that an in -lieu fee be collected. The Environmental Design and Protection Committee commented that the new building will benefit from the existing screening vegetation currently in place but screening the existing secondary dwelling unit is recommended. ENVIRONMENTAL CLEARANCE (CEQA) The proposed single family residence is categorically exempt from the provisions of the California Environmental Quality Act by provision of Section 15303(a) & (e). ATTACHMENTS 1. Recommended conditions of approval 2. Grading Policy Exception Findings 3. Los Altos Hills Grading Policy 4. Cotton and Shires Associates Letter, February 28, 2011 5. Environmental Design and Protection Committee Comments, March 10, 2011 6. Pathways Committee minutes from meeting on February 28, 2011 7. Fire Department Comments, February 23, 2011 8. Proposed development plans Planning Commission Lands of Thrun May 5, 2011 Page 6 ATTACHMENT 1 RECOMMENDED CONDITIONS FOR SITE DEVELOPMENT PERMIT FOR A NEW RESIDENCE AND SWIMMING POOL LANDS OF THRUM, 13818 PAGE MILL ROAD File # 257-10-ZP-SD-GD PLANNING DEPARTMENT: 1. No other modifications to the approved plans are allowed except as otherwise first reviewed and approved by the Planning. Director or the Planning Commission, depending on the scope of the changes. 2. All existing Blue Gum (E. globulus), Pink Ironbark (E. sideroxylon rosea), River Red Gum (E. camaldulensis), Swamp Gum (E. rudis), Honey Gum (E. melliodora), or Manna Gum (E. viminalis) eucalyptus trees on the property located within 150' of any structures or 'roadways shall be removed prior to final inspection. Removal of eucalyptus trees shall take place between the beginning of August and the end of January to avoid disturbance of nesting birds protected under the Federal Migratory Bird Treaty Act (MBTA) and California Department of Fish and Game Code Section 3500 et seq unless a nesting bird survey is first conducted and there is a determination that there are no active nests within the tree. 3. After completion of rough framing or at least six (6) months prior to scheduling a final inspection, the applicant shall submit landscape screening and erosion control plans for review by the Site Development Authority. The application for landscape screening and erosion control shall be accompanied by the applicable fee and deposit. The plans shall be reviewed at a noticed public hearing. Attention shall be given to plantings which will be adequate to break up the view of the new residence from surrounding properties. All landscaping required for screening purposes and for erosion control (as determined by the City Engineer) must be installed prior to final inspection. 4. A landscape maintenance deposit in the amount of $5,000 shall be posted prior to final inspection. An inspection of the landscape to ensure adequate establishment and maintenance shall be made two years after the installation. The deposit will be released at that time if the required plantings remain viable. Planning Commission Lands of Thrun May 5, 2011 Page 7 5. Prior to requesting the foundation inspection, a registered civil engineer or licensed land surveyor shall certify in writing and state that "the location of the new residence and roof eaves are no less than 40' from the fi°ont property line and 30' from the sides and rear property lines." The elevation of the new residence shall be similarly certified in writing to state that "the elevation of the new residence matches the elevation and location shown on the approved Site Development plan." The applicant shall submit the stamped and signed letter(s) to the Planning Department prior to requesting a foundation inspection and prior to final inspection. 6. Prior to requesting the final framing inspection, a registered civil engineer or licensed land surveyor shall certify in writing and state that "the height of the new residence complies with the structure height shown on the approved plans, measured as the vertical distance at any point from the building pad, to the -highest part of the structure directly above (including roof materials)." The overall structure height shall be similarly certified in writing and state that "all' points of the building (including chimneys and appurtenances) lie within a thirty-five (35) foot horizontal band measured from the lowest visible natural or finished grade topographical elevation of the structure along the building line and the highest point of the roof structure or appurtenance." The applicant shall submit the stamped and signed letter(s) to the Planning Department prior to requesting a final framing inspection and prior to final inspection. 7. Building mounted shall have frosted glass or be down lights. No lighting may be placed within setbacks except two entry or driveway lights. 8. Skylights shall be designed and constructed to reduce emitted light (tinted or colored glass, or other material). No lighting may be placed within skylight wells. 9. Fire retardant roofing (Class A) is required for all new construction. 10. No new fencing or gates are approved. Any new fencing, walls or gates shall require review and approval by the Planning Department, prior to installation. 11. At the time of submittal of plans for building plan check, the applicant shall submit one of the following checklists to demonstrate compliance with the Town's Green Building Ordinance: a. A GreenPoint rated checklist with the building permit application to indicate that the project will achieve a minimum of fifty (50) Planning Commission Lands of Thrun May 5, 2011 Page 8 points. The checklist shall be completed by a qualified green building professional and shall be attached to the front of the construction plans. The construction plans shall include general notes or individual detail drawings, where feasible, showing the green building measure to be used to attain the required points. b. A LEED for Homes checklist with the building permit application to indicate that the project will achieve a minimum of forty-five (45) points or LEED certification. The checklist shall be completed by a qualified green building professional and shall be attached to the front of the construction plans. The construction plans shall include general notes or -individual detail drawings, where feasible, showing the green building measure to be used to, attain the 'required points. 12. Prior tofinal inspection and occupancy, a qualified professional as for the scoring system used (GreenPoint Rater or a LEED AP) shall provide documentation to the Planning Department verifying that the building was constructed in compliance with GreenPoint Rated or LEED° certification. 13. All properties shall pay School District fees to either the Los Altos School District or the Palo Alto Unified School District, as applicable, prior to acceptance of plans for building plan check. The applicant must take a copy of worksheet #2 to school district offices (both elementary and high school in the Los Altos School District), pay the appropriate fees and provide the Town with a copy of the receipts. 14. For swimming pools, at least one of the following safety features shall be installed to the satisfaction of the Town Building Official: a. The pool shall be isolated from access to the residence by an -enclosure (fencing). b. The pool shall be equipped with an approved safety pool cover. c. The residence shall be equipped with exit alarms .on those doors providing direct access to the pool. d. All doors providing direct access from the home to the swimming pool shall be equipped with a self-closing, self -latching device with a release mechanism placed no lower than 54 inches above the floor. 15. Standard swimming pool conditions: a. Lights shall be designed so that the source is not visible from off-site. b. Drainage outfall structures shall be constructed and located to the satisfaction of the City Engineer. c. Pool equipment shall be enclosed for noise mitigation and screening. The pool equipment enclosure shall be screened with landscaping and may not encroach into any required setbacks. Planning Commission Lands of Thrun May 5, 2011 Page 9 16. An ISA Certified Arborist shall certify in writing and state that "all of the recommendations in the Ian Geddes and Associates reports dated December 29, 2010 and April 26, 2011 were implemented during the construction process" The applicant shall submit wet signed letters) .to the Planning Department prior to requesting a final inspection. 17. Prior to beginning any grading operation, tree fencing for all oak trees 6" in diameter and greater. The tree protection measures must be implemented throughout the course of construction. Town staff must inspect the fencing and the trees to be fenced prior to commencement of grading. The property owner shall call for said inspection at least three days in advance of the inspection. No storage of equipment, vehicles or debris shall be allowed within the drip lines of these trees. 18. The property owner shall install 12-36" box sized native oak trees prior to final inspection. The location of these required plantings shall be shown on the landscape screening plan. At the applicant's request, the Town Arborist can inspect the three (3) oak trees that will be impacted by the rear yard retaining wall. The mitigation plantings can be reduced by a 3:1 ration if any trees are found to be in good health with a good prognosis. ENGINEERING DEPARTMENT: 19. As recommended by Cotton, Shires & Associates, Inc., in their letter dated February 28, 2011, the applicant shall comply with the following: a. Geotechnical Plan Review - The applicant's geotechnical consultant shall review and approve all geologic and geotechnical aspects of the project building and grading plans (i.e., site preparation and grading, site drainage improvements and design parameters for foundations) to ensure that their recommendations have been properly incorporated. • The Project Geotechnical Consultant shall verify that the proposed improvements are located a sufficient distance from areas of the past slope instability. The slope area north of the residence shall be examined. Any appropriate remedial measures shall be. recommended. • The Project Geotechnical Consultant shall review the location of the proposed southern energy dissipater on Civil Plan Sheet #2. The currently proposed location appears to coincide with an area of previous instability/erosion. Planning Commission Lands of Thrun May 5, 2011 Page 10 The results of the plan review shall be summarized by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to acceptance of plans for building plan check. b. Geotechnical Construction Inspections - The geotechnical consultant shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections shall include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations and retaining walls prior to the placement of steel and concrete. The results of these inspections and the as -built conditions of the project shall be described by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to final inspection. 20. Peak discharge at 13818 Page Mill Road, as a result of Site Development Permit 257-10, shall not exceed the existing pre -development peak discharge value of the property. Detention storage must be incorporated into the project to reduce the predicted peak discharge to the pre - development value.. Provide the data and peak discharge hydrologic . model(s) utilized, as well as, the calculations of the peak discharge value prior and post development. Determine the design peak runoff rate for a 10 -year return period storm and provide detention'storage design plans to reduce the predicted peak discharge to the pre -development value. All documentation, calculations, and detention storage design (2 plan copies) shall be submitted for review and approval to the satisfaction of the City Engineer prior to acceptance of plans for building plan check. 21. Any, and all, changes to the approved grading and drainage plan shall be submitted as revisions from the project engineer and shall first be approved by the Town Engineering Department. No grading shall take place during the grading moratorium (October 15 to April 15) except with prior approval from the City Engineer. No grading shall take place within ten feet of any property line except to allow for the construction of the driveway access. 22. All public utility services serving this property shall be placed underground. The applicant should contact PG&E immediately after issuance of building permit to 'start the application process for undergrounding utilities which can take.up to 6-8 months. Planning Commission Lands of Thrun May 5, .2011 Page 11 23. Two copies of an erosion and sediment control plan shall be submitted for review and approval by the Engineering Department prior to acceptance of plans for building plan check. The contractor and the property owner shall comply with all appropriate requirements of the Town's NPDES permit relative to grading and erosion/sediment control. The first 100 feet of the driveway shall be rocked during construction and all cut and fill slopes shall be protected from erosion. All areas on the site that have the native soil disturbed shall be protected for erosion control during the rainy season and shall be replanted prior to final inspection. 24. Two copies of a grading and construction operation plan shall be submitted by the property owner for review and approval by the City Engineer and Planning Director prior to acceptance of plans for building plan check. The grading/construction operation plan shall address truck traffic issues regarding dust, noise, and vehicular and pedestrian traffic safety on Moon Lane, Page Mill Road, and surrounding roadways, storage of construction materials, placement of sanitary facilities, parking for construction vehicles, clean-up area, and parking for construction personnel. A debris box (trash dumpster) shall be placed on site for collection of construction debris. Arrangements must be made with the GreenWaste Recovery, Inc. for the debris box, since they have a franchise with the Town and no other hauler is allowed within the Town limits. 25. The property owner shall inform the Town of any damage and shall repair any damage caused by the construction of the project to pathways, private driveways, and public and private roadways, prior to final inspection and .release of occupancy permits and shall provide the Town with photographs of the existing conditions of the roadways and pathways, prior to acceptance of plans for building plan check. 26. The driveway shall be required to be fully constructed and to be roughened where the pathway intersects, to the satisfaction of the City Engineer, prior to final inspection. 27. The property owner shall be required to connect to the public sanitary sewer prior to final inspection. A sewer connection permit shall be required by the Town's Public Works Department, prior to acceptance of plans for building plan check. 28. The property owner shall pay the Pathway in -lieu fee, prior to acceptance of plan for building plan check. Planning Commission Lands of Thrun May 5, 2011 Page 12 FIRE DEPARTMENT: 29. An automatic residential fire sprinkler system approved by the Santa Clara County Fire Department shall be included in all portions of the building. Three sets of plans prepared by a sprinkler contractor shall be submitted to the Santa Clara County Fire Department (14700 Winchester Blvd., Los Gatos, CA 95032) for review and approval. The sprinklers shall be inspected and approved by the Fire Department, prior to final inspection and occupancy of the new residence. 30. The applicant shall provide an approved fire department engine driveway turnaround with a minim radius of 36 feet outside and 23 feet inside. 31. The applicant shall provide an access driveway with a paved all weather surface, a minimum unobstructed width of 14', vertical clearance of 13'6", minimum circulating turning radius of 36' outside and 23' inside, and a maximum slope of 20%. 32. This project is located within. the designated Wildland Urban Interface Fire Area. The building construction shall comply with the provisions of the California Building Code (CBC) Chapter 7A. Vegetation clearance shall be in compliance with CBC Section 701A.3.2.4 prior to project final approval. 33. Approved numbers or addresses shall be placed on all new and existing buildings in such a position as to be plainly visible and ,legible from the street or road fronting the property. Numbers shall contrast with their background. CONDITION NUMBERS 11a, 13, 19a, 20, 23, 24, 25, 27 AND 28 SHALL BE COMPLETED AND SIGNED OFF BY THE PLANNING DEPARTMENT AND/OR THE ENGINEERING DEPARTMENT PRIOR TO ACCEPTANCE OF CONSTRUCTION PLANS FOR PLAN CHECK BY THE BUILDING DEPARTMENT. Project approval may be appealed if done so in writing within 22 days of the action. The building permit cannot be issued until the appeal period has lapsed. The applicant may submit construction plans to the Building Department after May 31, 2011 provided the applicant has completed all conditions of approval required prior to acceptance of plans for building plan check. Upon completion of the construction, a final inspection shall be required to be set with the Planning and Engineering Departments two weeks prior to final building inspection approval. Planning Commission Lands of Thrun May 5, 2011 Page 13 NOTE: The Site Development permit is valid for one year from the approval date (until May 5, 2012). All required building permits must be obtained within that year and work on items not requiring a building permit shall be commenced within one year and completed within two years. Planning Commission Lands of Thrun May 5, 2011 Page 14 ATTACHMENT 2 RECOMMENDED FINDINGS FOR GRADING POLICY EXCEPTION LANDS OF THRUN, 13818 PAGE MILL ROAD File # 257-10-ZP-SD-GD 1. The proposed plan and grading is in substantial conformance with the General Plan Land Use Element General Policy 1.1 which states that "Uses of,land should maintain the semi -rural atmosphere, minimize disturbance to natural terrain, minimize removal of the natural vegetation and create the maximum compatibility of development with the natural environment through site design, architecture and landscaping." 2. The proposed grading employs a cut building pad and significantly lowers the profile of the residence and reduces overall visible bulk. Cut foundations are "generally preferred" over fill per the Grading Policy. 3. The proposed grading will not result in the removal of any substantial vegetation that cannot be effectively mitigated. 4. The proposed grading will not increase the quantity of runoff. 5. The proposed area of grading will not result in a substantial visual alteration of the natural terrain. The property's existing contours and basic landform are retained. 6. The proposed grading will not result in the placement of retaining walls that are highly visible from off-site. 7. The proposed area requiring exception is a small area, 1.8% of the property size. TOWN OF LOS ALTOS MILLS 26379 Fremont Road Los Altos Hills, CA 94022 Phone: (650) 941-7222 www.losaltoshills.ca.gov Code Sections: Attachment 3 LOSALT05IRLL8 1 CALIFORNIA Grading Policy Approved by City Council — 4/2/97 Section 10-2.7020 of the Site Development Ordinance_ states that: "The amount of grading, excavation, or fill shall be the minimum necessary to accommodate proposed structures, unless grading is proposed to lower the profile of buildings." Section 10-2.703(a) requires: "Type H foundations — step -on -contour, daylight., pole foundations, or a combination thereof — shall be used on building sites with natural slopes in excess of fourteen percent (14%)." Intent: The purpose of this policy is to outline desired criteria for grading which assure that construction retains the existing contours and basic landform of the site to the greatest extent feasible. It is also intended that the policy provide guidance for "stepping" structures down sloped hillsides, and emphasizes cut to lower the profile of structures over fill or foundation walls, which tend to raise the profile of the structure. While balanced_ cut and fill is desirable to minimize import or export of soil, to or from a site, it is recognized that the Town's policies and the guidelines below may encourage export as cut is generally preferred over fill. These policies are intended to be used by staff in evaluation and malting recommendations to the Planning Commission and/or City Council regarding site, development applications, and as guidance for applicants. Individual sites may dictate a need to deviate from the criteria, to the extent permitted by the Planning Commission and/or City Council. Grading Policy Page 2 Polic 1. Cuts and fills in excess of the following levels generally will be considered excessive and contrary to Town ordinances and policies to grade only to the minimum extent necessary to accommodate structures and to site structures consistent with slope contours, i.e., "step down" the hill*: Cut Fill House 8'** 3' Accessory Bldg. 4' 3' Tennis Court 6' 3' Pool 4'*** 3' Driveways 4' 3' Other (decks, yards) 4' 3' * Combined depths of cut plus fill for development other than the main residence should be limited to 6 feet, except that for tennis courts cut plus fill may be permitted up to a maximum of 8 feet_ ** Excludes basements meeting Code definition. *** Excludes excavation for pool. 2. The height of the lowest finished floor(s) of a structure should generally not be set in excess of three (3) feet above the existing grade, to assure that structures step with the- slope. heslope. 3. Driveway cut may be increased up to a maximum of eight feet (8D for the portion of the driveway oz backup area which is adjacent to a garage that has been lowered with a similar amount of cut. 4. Cut and/or fill for drainage shall be limited consistent with the guidelines set forth above for each type of structure, but shall be the minimum grading needed for drainage purposes, as determined by the City Engineer. COTTON, SHIRES AND ASSOCIATES, INC. CONSULTING ENGINEERS AND GEOLOGISTS TO: Brian Froelich Associate Planner TOWN OF LOS ALTOS HILLS 26379 Fremont Road .Los Altos Hills, California 94022 SUBJECT: Geotechnical Peer Review RE: Thrun, New Residence 257-10-ZP-SD-GD 13818 Page Mill Road Attaclunent 4 February 28, 2011 L5150 At your request, we have completed a geotechnical peer review of the applications for the proposed addition using: Geotechnical Investigation (report) prepared by Murray _ Engineers, Inc., dated February 4; 2011; • Architectural Plans (17 sheets) pr'ep'ared -'by Eli Attia Architect, dated February 11, 2011; and • Grading, Drainage, and Erosion Plans (3 sheets) prepared by Giuliani and Kull Inc., dated February 11, 2011. In addition, we completed a recent site inspection and reviewed pertinent technical documents from our office files. DISCUSSION The applicant proposes to demolish the existing residence and construct a new residence with 'full basement. Other site improvements include construction of swimming pool, : reflection pool, and various landscape/ perimeter retaining walls. Provided estimates of project earthwork include' 671 cubic yards of cut and 18 cubic yards of fill. Northern California Office 330 Village Lane Los Gatos, CA 95030-7218 (408) 354-5542 • Fax (408) 354-1852 www.cottonshires.com Central California Office 6417 Dogtown Road San Andreas, CA 95249-9640 (209) 736-4252 • Fax (209) 736-1212 Brian Froelich Page 2 SITE CONDITIONS February 28, 2011 L5150 The subject property encompasses the top of a knoll with surrounding gentle to very steep (approximately 5 to 67 percent inclination) hillside topography. Initial grading for the site resulted in a radial fill prism surrounding the existing residence and parking pad. A fill prism lies along the northern edge of the existing driveway with steep to precipitous (approximately 45 to 100 percent) slopes. Other fill prisms that surround the building pad and driveway are moderately steep (approximately 25 to 29 percent inclination). A steep (approximately 40 percent inclination) cut slope is located along the inboard edge of the driveway. Indications of shallow landshding were noted along the southern and northern portion of the property. An old landslide along the northern slope of the property displays an apparent 5 -foot headscarp that is located approximately 20-leet from the edge of the parking pad. We also noted other apparent subdued landslide features along site southern slopes that displayed hummocky terrain: Indications of potentially expansive colluvium/fill materials including desiccation cracks were observed within landscaped areas. Signs of fill settlement/ creep were also noted along the outboard edges of the pool fill pad. Drainage is characterized by radial sheetflow and channelized flow along a developed swale within the southeastern portion of the property. The Town Geologic Map indicates that the property is underlain, at depth, by sedimentary bedrock materials of Santa Clara Formation. The bedrock is overlain by potentially expansive sandy clay. The nearest trace of the potentially active Monta Vista fault is mapped approximately 1,650 feet southwest of the subject property. Additionally, the active San Andreas fault is located approximately 2.9 miles southwest of the site. CONC-LUSIONS AND RECOMMENDED NDED ACTION Proposed site development appears to be constrained by potentially expansive surficial soils, artificial fill materials, and anticipated future strong seismic ground shaking. We have noted several shallow landslide features at the site that potentially impact perimeter improvements such as proposed energy dissipaters. The site soil investigation and geotechnical design recommendations appear to be in general conformance with prevailing standards of geotechnical practice. We recommend that the following conditions be attached to geotechnical approval of permit applications for the project. COTTON, SHIRES AND ASSOCIATES, INC. Brian Froelich Page 3 February 28, 2011 L5150 1. Geotechnical Plan Review - The applicant's geotechnical consultant should review and approve all geotechnical aspects of the project building and grading plans (i.e., site preparation and grading, site drainage improvements and design parameters for foundations) to ensure that their recommendations have been properly incorporated. The Project Geotechnical Consultant. should verify that proposed improvements are located a sufficient distance from areas of past slope instability. The slope area north of the proposed residence should be examined. Am., appropriate remedial measures should be recommended. The Project Geotechnical Consultant should review the location of the proposed southern energy dissipater on the Civil Plan Sheet 2. The current proposed location appears to coincide with an area of previous instability/ erosion. The results of the Geotechnical Plan Review should be summarized by the geotechnical consultant in a letter and submitted to the Town Engineer along with other documentation for building permit plan -check. 2. Geotechnical Construction Inspections - The geotechnical consultant should inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections should include, but not necessarily be limited to: site _preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations and retaining walls prior to the placement of steel and concrete. The results of these inspections and the as -built conditions of the project should be described by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to final (as -built) project approval. LIMITATIONS This geotechnical peer review has been performed to provide technical advice to assist the Town with its discretionary permit decisions. Our services have been limited to review of the documents previously identified, and a visual review of the property. COTTON, SHIRES AND ASSOCIATES, INC. Brian Froelich Page 4 February 28, 2011 L5150 Our opinions and conclusions are made in accordance with generally accepted, principles and practices of the geotechnical profession. This warranty is in lieu of all other warranties, either expressed or implied. TS:DTS:JN:kd Respectfully submitted, COTTON, SHIRES AND ASSOCIATES, INC. TOWN GEOTECHNICAL CONSULTANT Ted Savre Principal Engineering Geologist CEG 1795 �C David T. Schrier Principal Geotechnical Engineer GE 2334 COTTON, SHIRES AND ASSOCIATES, INC. Attachment 5 Environmental ]Design and Protection Committee New Residencefgxn+94d Evaluation Reviewed by:� �( Date (D Applicant Name t 0-p 0 tj Address 1 l PO --C Site impact/lighting/noise: Creeks, drainage, easements: L U Existing Vegetation: Significant issues/comments: C7Lk_ MAR 10 2011 TOWN ®f LOS ALTOS HILLS Attachment 6 Los Altos Hills Pathway Committee DRAFTI Minutes of Meeting February 28, 2011 1. ADMINISTRATIVE Chairman Eileen Gibbons called the meeting"to order at 7:05 PM Members present: Courtenay Corrigan, Nick Dunckel, Eileen Gibbons, Breene Kerr, Bob Stutz, Sue Welch, Denise Williams Members absent: Ann Duwe, Tim Warner LAH Council Members present: Breene Kerr, Ginger Summit Members of the public present: Eli Attia, architect was present representing 13818 Page Mill Road The agenda was approved as published. 2. Communications from the floor. None 3. Property Reviews. The following properties were reviewed for pathway recommendations: a) 13818 Page Mill Road (Lands of Thrun, Sebastian, and Petra) The reason for pathway review is construction of a new residence. The architect, Eli Attia, was present representing the homeowners. The 9 -acre property has a Page Mill address, but is actually on the south side of Moon Lane. Moon Lane is a cul-de-sac; it is a private after 13816, but Chairman Gibbons reported that the Town holds an easement that confers right-of-way for the public. Easement maps show an in -road easement the full length of Moon Lane (connecting to the off-road path) and a planned roadside path with easement on 13826 and 13818 Page Mill. An established off-road path (on a gravel/grass fire road) exits from the eastern end of Moon Lane and connects to Saddle Mountain Drive. It is unclear how many residences Moon serves. The PWC visited the site on February 26, 2011 and walked the fire road, and spoke with the homeowner, who said he had no objections to a path along Moon Lane. Sue Welch moved that the owners of 13818 Page Mill Road be asked to pay a pathway in -lieu fee. Breene Kerr seconded and amended the motion to ask that staff confirm that the Town holds an easement conferring public access all along on Moon Lane. Eileen Gibbons seconded. The vote was unanimously in favor. 4. Reports from Other Meetings Breen Kerr distributed information from the Valley Transportation Authority (VTA) a) Info on a bicycle and pedestrian workshop to solicit feedback from cyclists on rural roads in the area that are heavily used and potentially in need of improvements (Popular Bicycle Rides on Country Roads, March 9, 2011) b) Santa Clara County project priority list update showing projects to be funded (or not) by the Roads and Airports Department. Addition of roadside paths to Moody Road between Hidden Villa and Canyon Road is on the list but will not be funded. BK suggested that involvement of the PWC help the Town get funding. 5. Old Business a) Addition of La. Loma Annex Off -Road Pathway to Master Path Plan (MPP). Eileen Gibbons met with Richard Chiu and Debbie Pedro to review he procedure for adding segments to the MPP. She will put the request for amendment of the MPP before City Council for approval on February DraftlPWC_Minll-0228 3/18/I1 FIRE DEPARTMENT SANTA CLARA COUNTY Mum 14700 Winchester Blvd., Los Gatos, CA 95032-1818 (408) 378-4010 m (408) 378-9342 (fax) • www.FcFf8.t 4 2011 Attaclnnent 7 Internationally Accredited Agency TORO OP L ALTOSH REPLAN V EW 1 1 0437 000666 No. BLDG DEVELOPMENTAL REVIEW COMMENTS PERMIT No. _ . ...... _. :Proposed new 9,942 square -foot one-story single-family residence with basement and attached :garage. 'Comment #1: Review of this Developmental proposal is limited to acceptability of site access and ,water supply as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work the applicant shall make application to, and receive from, the Building Department all applicable construction permits. Comment #2: Wildland-Urban Interface: This project is located within the designated Wildland -Urban Interface Fire Area. The building construction shall comply with the provisions of California Building Code (CBC) Chapter 7A. Note that vegetation clearance shall be in compliance with CBC :Section 701A.3.2.4 prior to project final approval. Check with the Planning Department for related :landscape plan requirements. ;Comment #3: Fire Sprinklers Required: An automatic sprinkler system shall be provided throughout all new buildings and structures exceeding one (thousand) square feet. NOTE: Covered 'porches, patios, balconies, and attic spaces may require fire sprinkler coverage. A State of California .licensed (C-16) Fire Protection Contractor shall submit plans, calculations, a completed permit :application and appropriate fees to this department for review and approval prior to beginning their work. CFC Sec. 903.2, as adopted and amended by LAMC Noted on Page A0.01 of the plans 'Comment #4: Potable water supplies shall be protected from contamination caused by fire Protection water supplies. It is the responsibility of the applicant and any contractors and subcontractors to contact the water purveyor supplying the site of such project, and to comply with the requirements of that purveyor. Such requirements shall be incorporated into the design of any :water-based fire protection systems, and/or fire suppression water supply systems or storage 'containers that may be physically connected in any manner to an appliance capable of causing :contamination of the potable City PLANS SPECS NEW RMDL AS LAH N ❑ N ❑ ❑ OCCUPANCY SFR CONST. TYPE V -B ApplicantName Eli Attia Architect DATE 2/23/2011 PAGE 1 OF 2 SEC/FLOOR 1 +bsmt AREA 9942 sf LOAD PROJECT DESCRIPTION Residential Development PROJECT TYPE OR SYSTEM Design Review NAME OF PROJECT SFR LOCATION 13818 Page Mill Rd Los Altos Hills TABULAR FIRE FLOW 2750 REDUCTION FOR FIRE SPRINKLERS REQUIRED FIRE FLOW @ 20 PSI 1500 BY Harding, Doug 1 50% Organized as the Santa Clara County Central Fire Protection District Serving Santa Clara County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos, Monte Sereno, Morgan Hill, and Saratoga FIRE s .. �� DEPARTMENT x c�4.Je �� " t 'SANTA CLARA COUNTY 14700 Winchester Blvd., Los Gatos, CA 95032-18181 ,PER 2 4 2all (408) 378-4010 • (408) 378-9342 (fax) • wk .sccfd.org INS -, V i iO� Lf �� �'CC11EDttP Internationally Accredited Agency a �s ION OF 06 ALTQM REVIEW 1 1 No. - BLDG DEVELOPMENTAL REVIEW COMMENTS PERMIT No. 0437 :water supply of the purveyor of record. Final approval of the system(s) under consideration will not be granted by this office until compliance with the requirements of the water purveyor of record are. documented by that purveyor as having been met by the applicant(s). 2007 CFC Sec. 903.3.5 and Health and Safety Code 13114.7 Comment #5: Fire Apparatus (Engine)Access Driveway Required: Provide an access driveway with a paved all weather surface, a minimum unobstructed width of 14 feet, vertical clearance of 13 feet 6 inches, minimum circulating turning radius of 36 feet outside and 23 feet inside, and a maximum slope of 157o. Installations shall conform to Fire Department Standard Details and Specifications :sheet D-1. CFC Sec. 503 ;Comment #6: Fire Department (Engine) Driveway Turn -around Required: Provide an approved fire department engine driveway turnaround with a minimum radius of 36 feet outside and 23 feet ,inside. Installations shall conform with Fire Department Standard Details and Specifications D-1. CFC: :Sec. 503 Comment #7: Premises Identification: Approved numbers or addresses shall be placed on all new :and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Numbers shall contrast with their background. CFC Sec. 505 To prevent plan review and inspection delays, the above noted Developmental Review 'Conditions shall be restated as "notes" on all pending and future plan submittals and any referenced diagrams to be reproduced onto the future plan submittal. City LAH PLANS SPECS NEW RMDL AS ® ❑ ® ❑ ❑ OCCUPANCY SFR CONST, TYPE V -B AppllcantName Eli Attia Architect DATE 2/23/2011 PAGE 2 OF 2 SEC/FLOOR 1 +bsmt AREA 9942 sf LOAD PROJECT DESCRIPTION Residential Development PROJECT TYPE OR SYSTEM Design Review NAME OF PROJECT SFR LOCATION 13818 Page Mill Rd Los Altos Hills TABULAR FIRE FLOW 2750 REDUCTION FOR FIRE SPRINKLERS REQUIRED FIRE FLOW @ 20 PSI 1500 BY Harding, Doug 50% Organized as the Santa Clara County Central Fire Protection District Serving Santa Clara County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos, Monte Sereno, Morgan Hill, and Saratoga