Loading...
HomeMy WebLinkAbout8.2TOWN OF LOS ALTOS HILLS NOTICE OF FAST TRACK PUBLIC HEARING NOTICE IS HEREBY GIVEN that the City Clerk of the Town of Los Altos Hills, State of California, has set after the hour of 10:15 a.m. TUESDAY, JANUARY 17, 2012 in the Council Chambers of Town Hall, 26379 Fremont Road, Los Altos Hills, California, as the time and place for a Public Hearing on the application of: LANDS OF MATHEWS; 12271 Hilltop Drive; File #254-11-ZP-SD; A request for a Site Development Permit for a new 4,423 square foot two story residence (maximum height 27') with a 680 square foot swimming pool. CEQA review: Categorical Exemption per Section 15303 (a) & (e) (staff -Nicole Horvitz). The file for the application is at the Office of the City Clerk at the Los Altos Hills Town Hall, 26379 Fremont Road, Los Altos Hills, California and may be reviewed at that location upon request. All interested persons may appear and be heard at said time and place. Written communications should be filed at Town Hall prior to the date of the hearing. Court challenges to the action of the Site Development Committee, Planning Commission, or City Council may be limited to issues raised at the public hearing described in this notice, or in written correspondence received at Town Hall at, or prior to, the time of the public hearing. Further details may be obtained from the Planning Department at (650) 941- 7222. Debbie Pedro, AICP Planning Director Town of Los Altos Hills NOTICE DATE: January 6, 2012 Item 8.2 Town Of Los Altos Hills January 17, 2012 Fast Track Hearing Fact Sheet Project Description: New Residence with a swimming pool File Number: 254-11-ZP-SD Site Address: 12271 Hilltop Drive Owner(s): Peter & Cherylan Mathews Staff Planner: Nicole Horvitz, Assistant Planner Site Data Net Lot Area: 1.00 acre Average Slope: 5.28% Lot Unit Factor: 1.00 Floor and Development Area (square footage): Area Type Maximum Existing Proposed Increase Remaining Development 15,500* 9,441 15,348 5,907 152 Floor 6,000 4,129 4,423 294 1,577 *includes 500 square foot solar bonus per LAMC section 10-1.502 Height: Maximum Proposed On Vertical Plane 27 ft. 27' ft. Lowest to Highest 35 ft. 27'6" ft. Setbacks: Minimum Proposed Front 40 ft. >40 ft. Sides 30 ft. >30 ft. Rear 30 ft. >30 ft. Exterior Materials: Stucco and cedar siding with a Firestone thermoplastic polyolefin (TPO) roof Parking: Required spaces: 4, out of setbacks. Proposed: 4 (3 garage spaces) out of setbacks. Green Point Rated: 157 points Fast Track Point: 6 points Grading: Cut: 20-CY Fill: 0-CY Export: 20-CY Sewer/Septic: Sewer system Environmental Design and Protection Committee: Commented on the number of proposed exterior lighting (applicant has modified plans per comments). Open Space Committee: None Pathways Committee: The property owner shall pay a pathway fee of $50.00 per linear foot of the average width of the property