Loading...
HomeMy WebLinkAbout3.2 TOWN OF LOS ALTOS HILLS January 28, 1998 Staff Report to the Planning Commission RE: SITE DEVELOPMENT PERMIT FOR A NEW RESIDENCE; LANDS OF MALEK; 11972 RHUS RIDGE ROAD; #254-97-ZP-SD-GD-VAR. FROM: Susan Manca, PlannerS-- APPROVED BY: Curtis S. Williams, Planning Direg RECOMMENDATION That the Planning Commission: Approve the requested Site Development Permit and Variance, subject to the recommended conditions of approval. BACKGROUND The subject property is a vacant lot located at the west side of the Rhus Ridge cul de sac. The property is populated with numerous oaks, including several heritage oak trees and areas with slopes greater than 30 percent. The access to the lot is shared with the neighbors to the north. The property is a hillside lot, with the lot to the south at a higher elevation, and the other property boundaries lower than the building site. The property is bounded by the Mid Penninsula Open Space to the west. CODE REQUIREMENTS As required by Section 10-2.301 of the Site Development Ordinance, this application for a new residence has been forwarded to the Planning Commission for review and approval. Criteria for review from the Site Development Ordinance include grading, drainage,,building siting, pathways, landscape screening and outdoor lighting. Zoning Code review encompasses compliance with floor and development area requirements, setbacks, height and parking. The evaluation of the Variance should include many of the same items, concurrently evaluating the physical site conditions which result in an undue hardship on the property. The approval of a Variance also requires that certain findings be approved by the Planning Commission. Staff has prepared findings for approval (see Attachment#2)for the Commission's review. Planning Commission Lands of Malek January 28, 1998 Page 2 DISCUSSION Site Data: Gross Lot Area: 2.14 acres Net Lot Area: 2.14 acres Average Slope: 41.5% Lot Unit Factor: .696 Floor Area and Development Area: Area Maximum Proposed Existing Increase Left Development 5,220 6,245 0 +6,245 0 Floor 4,000 3,535 0 +3,535 +465 Site and Architecture The applicant is requesting approval of a site development permit for a one story residence with an attached three-car garage. The house would be 2,989 square feet and the garage 546 square feet in floor area. The house is designed to step with the natural slope of the building site with the garage graded under the main level. The height of the residence would be 16 to 20 feet for the majority of the residence and 27 feet at the two story section of the house at the garage only. The maximum height of the new residence will be 27 feet as measured from the natural grade. Story poles have been placed on the site for the Commission's review. Proposed exterior materials include stucco siding and trim, and a tile roof. Three skylights are proposed with the residence. The front entry is a one story element, 14 feet high. Exterior colors have not yet been chosen. Staff will review proposed colors for conformance with the Town's adopted color board,prior to the painting of the residence. Staff notes that the placement of the residence in respect to stepping with the natural grade and limiting the removal of trees is exemplary with respect to its consistency with the intent of the Code and the Town's Design Guidelines. Specifically, the residence includes 4 building pads to minimize grading into the site while maintaining compliance with the Town's grading guidelines except in a small area (60 square feet) of the master bathroom. In addition, a flat roof with some roof areas with a minimal pitch have been used in the design of the house to minimize height and reduce any bulk. The low roofline with the variations in height, stepping the house with the natural contours, as well as the siting of the residence around the oak trees, combine to provide a very low profile residence which fits very well into the site. Planning Commission Lands of Malek January 28, 1998 Page 3 Driveway & Parking The driveway from the Rhus Ridge cul de sac to the garage and turnaround circle is a minimum of 14 feet wide as requested by the Fire Department. The garage entry will not be seen from Rhus Ridge as recommended by the Town's Design Guidelines. The Zoning Ordinance requires at least four on-site parking spaces which have been shown in the garage and the turnaround area. The driveway and turnaround areas are proposed to be located almost completely out of the setbacks. A small section of the turnaround circle is proposed to be located within the side setback in order to avoid impacting an 18 inch oak tree. The entire driveway is proposed to be constructed of pavers rather than asphalt to help blend into the site and to minimize impact on the trees. Outdoor Lighting Outdoor lighting has not been shown on the plans. Staff has included the standard condition (#10) for outdoor lighting, requiring that fixtures be downshielded and that all locations be approved by the Planning Department, with a maximum of one fixture per exit except at the garage and front entry. Exterior lighting has been shown on the conceptual landscape plan but will not be approved with the approval of the residence. Landscaping and landscape lighting will be reviewed at a site development hearing for screening after the house has been framed. Trees & Landscaping There are numerous oaks that provide good screening of the site from Rhus Ridge and the neighboring properties. Condition of approval #4 requires that the trees be fenced for protection and preserved except for the 8 oaks and 3 bay trees proposed to be removed in the arborist's report (see attachment 5, also outlined on the engineer's site plan). It should be noted that only 2 oaks are proposed to be removed strictly for the construction of the project. Condition #2 also requires that an arborist be present during any construction located within the dripline of a heritage oak tree. A landscape plan is included with the plans for review, although a landscape screening plan will be reviewed at a site development hearing once the house is framed. Any planting required for screening or erosion control will be required to be planted prior to final inspection. The Environmental Design & Protection Committee commented that planting would be needed to screen car lights from the neighboring property and that the pathlights and uplights appear excessive. These items will be reviewed with the landscape plan at the site development hearing, required by condition#2. In addition, the Committee indicates that the removal of the oaks appears appropriate and that replacement oaks should be required. Staff has included the requirement for 5 replacement oaks on the site to be included with the landscape screening plan. Planning Commission Lands of Malek January 28, 1998 Page 4 Variance Staff has prepared findings to approve the variance (attachment #2). The residence and outdoor development area has been designed around the natural features of the site and to fit into the neighborhood. The majority of the requested development area is proposed to be constructed for the driveway and turnaround for the 4 required parking spaces. The applicant has designed the driveway and parking areas around the majority of the oaks on the site, which has increased the driveway development area above that required for a minimal driveway. The applicant has designed the driveway to be constructed of interlocking pavers to decrease the visible impact of the large driveway and to lessen the impact on the trees. In addition,the outdoor living areas have been shown to be flagstone set in sand, also to minimize impact to the trees and blend into the site. The proposed outdoor living area is limited to 250 square feet of development area, as most of the pathways are proposed to be constructed of materials which are not counted toward the development area. It should be noted that the engineer's plan indicates 800 square feet of development area proposed for patios which has included the proposed gravel pathways. The applicant has designed the size of the residence to fit into the immediate neighborhood. The applicant has surveyed the square footage of the homes in the immediate neighborhood and they range from 1,759 square feet to 5,470 square feet, with the average size being 3,200 square feet. It should benoted that these figures were compiled from the assessor's records which generally do not include garages as floor area. The applicant's proposal of a 3,535 square foot residence (including the garage) is well within the maximum allowable for the lot and is under the average for the neighborhood. Grading &Drainage The residence has been located at the most level area of the lot with the garage graded under the house. The house would follow the contours of the lot and step down with the changes in elevation. The maximum cut and fill for the residence meets the Town's grading guidelines except for a small portion (60 square feet) of the master bathroom which is up to 5 feet above natural grade. The outdoor living area is proposed at grade, with stepping stones in sand to minimize grading. The driveway requires up to 2 feet of cut for the turnaround area and a 3 foot high retaining wall at the entrance to the property. Two retaining walls are indicated to be constructed at the rear of the residence. The maximum heights of the walls would be 3 feet and they are proposed to be drystack walls to minimize impact on the trees. The Engineering Department has reviewed the plans and has recommended conditions of approval as specified in Attachment 1. Drainage is designed to sheet flow around the house and driveway. The Engineering Department will review and approve the final drainage plan prior to acceptance of plans for building plan check. Final "as-built" Planning Commission Lands of Malek January 28, 1998 Page 5 grading and drainage will be inspected by the Engineering Department, and any deficiencies will be required to be corrected prior to final inspection. Conservation Easement Staff recommends that a conservation easement be granted over any portions of the lot which have a slopegreater than 30 percent. Generally, this would be located along the western portion of the lot, to the west of the existing trail. The Planning Commission may consider requiring additional conservation easements over any oaks or groves of oaks. A condition has been included requiring a conservation easement(condition#10). Septic System The septic system for the residence has been designed at the lower portion of the lot, near the Rhus Ridge cul de sac. The-county health department and the Town's geotechnical consultant have reviewed the plans and have preliminarily approved the location of the system. Geotechnical Review The Town's geotechnical consultant had some initial concerns regarding the possible detrimental effect of the leachfield on the existing slope. The applicant's geotechnical consultant has addressed this concern and Cotton, Shires and Associates have consequently prepared conditions of approval for the project as designed (see Attachment #1). Fire Department Review The Santa Clara County Fire Department reviewed the plans and has requested that the property address be clearly visible fromthe street. The flow capacity of the nearest fire hydrant will be adequate for a home of the proposed size. The proposed driveway to the residence is designed with 2 short sections of slopes greater than the 15% maximum allowed by the Fire Code. The Fire Department has approved the proposed driveway with the condition that the residence be constructed with fire sprinklers. The driveway design has incorporated an emergency vehicle turnaround, which was required since the driveway distance to the residence from Rhus Ridge Road exceeds 150 feet. The emergency vehicle turnaround area is proposed to be constructed of grass cel to minimize the visual impact and has been counted at 10 percent of the area toward the development area. The Fire Department recommendations have been included as conditions in Attachment 1. Planning Commission Lands of Malek January 28, 1998 Page 6 Committee Review The Pathways Committee has not responded in writing regarding this project although the chair of the Pathway Committee has indicated that there would be no request for this property as no pathway is indicated on the master pathway plan. However a pathway in lieu fee is required per Section 10-2.608 of the Site Development Code, and condition #16 requires such payment prior to final building inspection.. The Environmental Design Committee recommended that screening be required along the north property line to screen headlights from cars on the driveway. The Committee also requests that the oaks which are being removed be replaced. Staff has incorporated these comments into condition of approval#2. The proposed residence has been designed around the constraints of the lot and the outdoor areas have been designed to have minimal impact on the numerous heritage oaks. The variance to exceed development area appears to .be appropriate due to the configuration of the driveway and minimal developed outdoor living area. Staff is available to answer any questions that the Commission or the public may have. ATTACHMENTS 1. Recommended conditions of approval 2. Recommended findings for the Variance 3. Comments from Santa Clara County_Fire Department, dated December 17, 1997 (two pages) 4. Letter from Cotton, Shires and Associates, dated January 7, 1998 (two pages) 5. Environmental Design & Protection Committee evaluations, received December 10, 1997 (one page) 6. Letter and Findings for Variance prepared by Mr. Malek(three pages) 7. Letter from Roger and Elizabeth Spreen, dated January 17, 1998 (three pages) 8. Letter from neighbors, dated November 15, 1997 (two pages) 9. Tree Survey prepared by John McClenahan dated October 6, 1997 (fifteen pages) 10. Worksheet#2 11. Development plans: site, floor and roof plans, elevations and sections (seven sheets) cc: Safwat Malek 101 First Street, Ste. 422 Los Altos, CA 94022 Conditions of Approval Lands of Malek Page 7 ATTACHMENT 1 RECOMMENDED CONDITIONS FOR SITE DEVELOPMENT PERMIT AND VARIANCE FOR NEW RESIDENCE LANDS OF MALEK, 11972 RHUS RIDGE ROAD A. PLANNING DEPARTMENT: 1. Any changes or modifications to the approved plans shall be approved by the Planning Director or the Planning Commission, depending upon the scope of the changes. 2. Subsequent to final framing, a landscape screening and erosion control plan shall be reviewed at a Site Development Hearing. Particular attention shall be given to plantings which will be adequate to break up the view of the new residence from surrounding properties and streets. At least five native oak trees are required to be planted with the landscape screening to replace the heritage oaks proposed to be removed for the construction. All landscaping required for screening purposes or for erosion control (as determined by the City Engineer) must be installed prior to final inspection, unless the Planning Director finds that unusual circumstances, such as weather or site conditions, require that planting be delayed. In those instances, a deposit of an amount equal to the cost of landscape materials and installation,to the satisfaction of the Planning Director, shall be submitted to the Town. Landscaping shall in any event be installed not later than six months after final inspection, or the deposit will be forfeited. 3. A landscape maintenance deposit (or certificate of deposit), equal to the cost of materials and installation for all landscaping required for screening purposes or for erosion control (as determined by the City Engineer), but not to exceed $5,000, shall be posted prior to final inspection. An inspection of the landscape to ensure adequate establishment and maintenance shall be made two years after installation. The deposit will be released at that time if the plantings remain viable. 4. Prior to beginning any grading or construction operations, all significant trees in the vicinity of construction shall be fenced at the dripline. The fencing shall be of material and structure to clearly delineate the dripline. Town staff must inspect the fencing and the trees to be fenced prior to commencement of grading or construction. The fencing must remain in place throughout the course of construction. No storage of equipment, vehicles or debris shall be allowed within the driplines of these trees. Any Conditions of Approval Lands of Malek Page 8 grading or work to be done within the dripline of a heritage oak must be supervised by a certified arborist and a report shall be submitted prior to final indicating the health of the heritage oaks and that any repair work on the trees has been completed. 5. Paint colors shall be chosen by the applicant and approved by staff in conformance with the Town's adopted color board, and shall exhibit a light reflectivity value of 50 or less. Roofs shall use materials which have a light reflectivity value of 40 or less. White trim area should be minimized, particularly on large surfaces such as doors, columns, railings, and trellises. A color sample shall be submitted to the Planning Department for approval prior to acceptance of plans for building plan check. All applicable structures shall be painted in conformance with the approved color(s)prior to final inspection. 6. Skylights shall be designed and constructed to reduce emitted light. No lighting may be placed within skylight wells. 7. Fire retardant roofing is required for the new construction. 8. Locations and specifications for outdoor lighting shall be submitted for Planning Department approval prior to acceptance of plans for building plan check. Any additional outdoor lighting shall be reviewed with the landscape plan. Lighting fixtures shall generally be downlights. Exceptions may be permitted in limited locations (entry, garage, etc.) or where the fixtures would not be visible from off site. Any security lighting shall be limited in number and directed away from clear view of neighbors, and shielding with shrouds or louvers is suggested. Lighting shall be low wattage, shall not encroach or reflect on adjacent properties, and the source or lighting should not be directly visible from off site. No lighting may be placed within the setbacks except for 2 driveway or entry lights, except where determined to be necessary for safety. 9. As recommended by Cotton, Shires & Associates in their report dated January 7, 1998,the applicant shall comply with the following: a. Prior to issuance of permits for project construction, detailed drainage design plans should be prepared. Discharge of concentrated water onto very steep slopes in the southwestern portion of the lot should be avoided because of potential erosion / slope stability impacts. Final site drainage design should be completed to the satisfaction of the project geotechnical consultant and town engineer. Conditions of Approval Lands of Malek Page 9 b. The applicant's geotechnical consultant shall review and approve all geotechnical aspects of the development plans (i.e. site preparation and grading, site drainage improvements and design parameters for foundations and driveway) to ensure that his recommendations have been properly incorporated. The results of the plan review should be summarized by the geotechnical consultant in a letter and submitted to the Town Engineer for review and approval prior to acceptance of plans for building plan check. c. The geotechnical consultant shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections should include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements,and excavations for foundations prior to placement of steel and concrete. The results of these inspections and the as-built conditions of the project shall be described by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to fmal (as built)project approval. For further details on the above requirements, please refer to the letter from Cotton, Shires &Associates dated January 7, 1998. 10. The applicant shall dedicate a conservation easement over the portion of the property which has a slope greater than 30 percent (over the area from the 240 foot contour to the west property line), as shown on the engineer's plan of the Site Development Plans. A legal description and plat prepared by a licensed land surveyor or registered civil engineer shall be submitted to and approved by the Engineering Department so that the Town may prepare the dedication document. The signed and notarized dedication document shall be returned to the Town for recordation prior to acceptance of plans for building plan check. B. ENGINEERING DEPARTMENT: 11. The site drainage associated with the proposed development must be designed as surface flow wherever possible to avoid concentration of the runoff. The proposed drainage shall be designed to maintain the existing flow patterns. Final drainage and grading shall be inspected by the Engineering Department and any deficiencies corrected to the satisfaction of the Engineering Department prior to final inspection. A letter shall be submitted from the project engineer stating that the drainage Conditions of Approval Lands of Malek Page 10 improvements were installed as shown on the approved plans and in accordance with their recommendations prior to final inspection. 12. Any, and all, changes to the approved grading and drainage plan shall be submitted as revisions from the project engineer and shall first be approved by the Town Engineering Department. No grading shall take place during the grading moratorium between November 1 and April 1 except with prior approval from the City Engineer. No grading shall take place within ten feet of any property line except to allow for the construction of the driveway access. 13. All public utility services serving this property shall be placed underground. 14. At the time of foundation inspection for the new residence and prior to final inspection, the location licensed land surveyor as being in/at the approved location and elevation shown on the approved Site Development plan. At the time of framing inspection for the new residence, the height of each building shall be similarly certified as being at the height shown on the approved Site Development plan. 15. An erosion and sediment control plan shall be submitted for review and approval by the Engineering Department prior to acceptance of plans for building plan check. The contractor and the property owner shall comply with all appropriate requirements of the Town's NPDES permit relative to grading and erosion/sediment control. The first 100 feet of the driveway shall be rocked during construction and all cut and fill slopes shall be protected from erosion. All areas on the site that have the native soil disturbed shall be protected for erosion control during the rainy season and shall be replanted prior to final inspection. 16. Two copies of a grading and construction operation plan shall be submitted by the property owner for review and approval by the City Engineer and Planning Director prior to acceptance of plans for building plan check The grading/construction plan shall address truck traffic issues regarding dust, noise, and vehicular and pedestrian traffic safety on Rhus Ridge Road and surrounding roadways; storage of construction materials; placement of sanitary facilities; parking for construction vehicles; and parking for construction personnel. A debris box (trash dumpster) shall be placed on site for collection of construction debris. Arrangements must be made with the Los Altos Garbage Company for the debris box, since they have a franchise with the Town and no other hauler is allowed within the Town limits. Conditions of Approval Lands of Malek Page 11 17. The property owner shall inform the Town of any damage and shall repair any damage caused by the construction of the project to pathways, private driveways, and public and private roadways,prior to final inspection and shall provide the Town with photographs of the existing conditions of the roadways and pathways prior to acceptance of plans for building plan check. 18. The driveway shall be required to be fully constructed, to the satisfaction of the City Engineer,prior to final inspection. C. FIRE DEPARTMENT 19. The driveway shall be a minimum of 14 feet wide, shall have a vertical clearance of 13 feet six inches, shall be designed and maintained to support the imposed loads of fire apparatus (40,000 pounds) and shall have an all weather surface. 20. The property address shall be placed on the property so that it is clearly visible and legible from Rhus Ridge Road. The address numbers shall be a minimum of four inches high and shall contrast with the background color. 21. Prior to final inspection, the applicant shall install a fire sprinklering system to assure that adequate flow is available to the residence. The design of the fire sprinklering system shall be reviewed and approved by the fire department prior to acceptance of plans for building plan check. 22. The emergency vehicle turnaround proposed shall be installed with engineering to support 40,000 pounds. 23. The required driveway installations shall be in place, inspected, and accepted by the Fire Department prior to the start of construction. Bulk combustible construction materials may not be delivered to the construction site until installations are completed as stated above. Upon completion of the construction, a final inspection shall be required to be set with the Planning and Engineering Departments two weeks prior to final building inspection approval. • Conditions of Approval Lands of Malek Page 12 CONDITION NUMBERS 5, 8, 9, 10, 15, 16, 17,AND 21 SHALL BE COMPLETED, ANDSIGNED OFF BY THE PLANNING DIRECTOR AND THE CITY ENGINEER PRIOR TO ACCEPTANCE OF CONSTRUCTION PLANS FOR PLAN CHECK BY THE BUILDING DEPARTMENT. Properties residing within the Los Altos School District boundaries must pay School District fees before receiving their building permit from Los Altos Hills. The applicant must take a copy of Worksheet #2 to both the elementary and high school district offices, pay the appropriate fees and provide the Town with a copy of their receipts. NOTE: The Site Development permit is valid for one year from the approval date (until January 28, 1999). All required building permits must be obtained within that year and work on items not requiring a building permit shall be commenced within one year and completed within two years. Findings for Variance Lands of Malek Page 13 ATTACHMENT 2 RECOMMENDED FINDINGS FOR APPROVAL OF VARIANCE TO ALLOW DEVELOPMENT AREA TO EXCEED MAXIMUM DEVELOPMENT AREA LANDS OF MALEK- 11972 RHUS RIDGE ROAD 1. Because of exceptional and extraordinary circumstances applicable to the subject property, including size, shape, topography, location or surroundings, the strict application of the provisions of this Title is found to deprive such property of privileges enjoyed by other properties in the vicinity and under identical zoning classification; The numerous oak trees on this property make it difficult to construct a driveway with the required parking spaces to meet the Town's and the Fire Department's requirements for a 14 foot wide driveway without impacting the trees. The project includes minimal outdoor living area and the residence has been designed under the maximum floor area. The size of the proposed residence is not out of character for the neighborhood. The location of the trees makes it extremely difficult to design a driveway of minimal area. 2. Upon the granting of the variance, the intent and purpose of the applicable sections of the Zoning Ordinance will still be served and the recipient of the variance will not be granted special privileges not enjoyed by other surrounding property owners. The proposed development for the site would not be out of character for the homes in the neighborhood or within the Town. The driveway has been designed larger than the minimum required to meet the Town's requirements to avoid the removal of several heritage oak trees. The use of pavers for all of the outdoor living area will help minimize the visual impact of the outdoor development area. 3. The granting of such variance will not be materially detrimental to the public welfare or injurious to the property, improvements or uses within the immediate vicinity and within the same zoning district. The granting of the variance for the additional development area would not negatively impact any neighboring properties, as the areas would have a negligible impact visually.No significant grading will be required and the development would not be located close to the neighboring properties. Findings for Variance Lands of Malek Page 14 4. The variance will not authorize a use or activity which is not otherwise expressly authorized by the Zoning District regulations governing the parcel of property. The proposed development area would be used for a driveway and outdoor living area which are uses that are consistent with the residential zoning designation of the property and surrounding properties. /-+iyac-kryt. .A* c co RECEIVED FIRE DEPARTMENT r FIRE aDEC Y� SANTA CLARA COUNTY CONTROL NUMBER 1997 LOS ALTOS HILLS (408) ,'ESI"1947'`, 14700 Winchester Blvd., Los Gatos, CA 95030-1818 BLDG PERMn{ COUarESYbSEHVICE (408) 378-4010 (phone) • (408) 378-9342 (fax) - PLAN REVIEW NUMBER 97-3276 FILE NUMBER 254-97-ZP-S DEVELOPMENT REVIEW COMMENTS CODE/SEC. SHEET NO. REQUIREMENT Review of site plan for proposed new 3,535 square foot single family residence and attached garage., The planner for this project is Ms. Susan Manca. Review of this Developmental proposal is limited to acceptability of site access and water supply as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work the applicant shall apply to the Building Department for applicable construction permits. UFC 1. Required Fire Flow: Required fire flow for this project is 1000 GPM at 20 psi Appendix 11A residual pressure. The required fire flow is available from area water mains and fire hydrant(s) which are spaced at the required spacing. UFC 2. Required.Access to Water Supply (Hydrants): Portions of the structure(s) are 903.2 greater than 150 feet of travel distance from the centerline of the roadway containing public fire hydrants. Provide an on-site fire hydrant OR provide an approved residential fire sprinkler system throughout all portions of the building. • UFC 3. Fire Apparatus (Engine)Access Driveway Required: Provide an access driveway 902.2.2 with a paved all weather surface and a minimum unobstructed width of 14 feet, vertical clearance of 13 feet 6 inches, minimum circulating turning radius of 36 feet outside and 23 feet inside, and a maximum slope of 15%. Installations shall conform to Fire Department Standard Details and Specifications D-1. DISTRICT PLANS SPECS NEW RMDL AS OCCUPANCY CONST.TYPE PERMITTEE DATE PAGE LAH ❑ ❑ ENVIRO INTERNATIONAL 12/11/97 1 OF 2 SECJFLOOR AREA LOAD DESCRIPTION BY Residential Development Hokanson,Wayne NAME OF PROJECT LOCATION SFR-MALEK 11972 Rhus Ridge A California Fire Protection District serving Santa Clara County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos, Monte Sereno, Morgan Hill, and Saratoga - FIRE DEPARTMENT SANTA CLARA COUNTY �� FIRE f � CONTROL NUMBER BEST:194r, 14700 Winchester Blvd., Los Gatos, CA 95030-1818 BLDG PERMIT NUMBER COURTESY 6 SERVICE (408) 378-4010 (phone) • (408) 378-9342 (fax) PLAN REVIEW NUMBER 97-3276 FILE NUMBER 254-97-ZP-S DEVELOPMENT REVIEW COMMENTS CODE/SEC. SHEET NO. REQUIREMENT UFC 4. Fire Department (Engine) Driveway Turn-around Required: Provide an 902.2.2.4 approved fire department engine driveway turnaround with a minimum radius of 36 feet outside and 23 feet inside. Installations shall conform with Fire Department Standard Details and Specifications D-1. NOTE: Turn-around proposal-using grass cell pavers shall be installed with engineering to support 40,000 pounds. UFC 5. Timing of Required Driveway Installations: Requireddriveway installations 901.3 shall be in place, inspected, and accepted by the Fire Department prior to the start of construction. Bulk combustible construction materials may not be delivered to the construction site until installations are completed as stated above. Clearance for building permits also may be held until installations are completed. UFC 6. Premises Identification: Approved numbers or addresses shall be placed on all 901.4.4 new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Numbers shall contrast with their background and be a minimum of four inches in height. • DISTRICT PLANS SPECS NEW RMDL AS OCCUPANCY CONST.TYPE PERMITTEE DATE PAGE LAH 0 0 0 0 0 ENVIRO INTERNATIONAL 12/11/97 2 OF 2 SECJFLOOR AREA LOAD DESCRIPTION BY Residential Development Hokanson,Wayne NAME OF PROJECT LOCATION SFR-MALEK 11972 Rhus Ridge A California Fire Protection District serving Santa Clara County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos,Monte Sereno, Morgan Hill, and Saratoga RECEIVED COTTON, SHIRES & ASSOCIATES, INC. JAN - 8 1998 CONSULTING ENGINEERS AND GEOLOGISTS TOWN OF LOS ALTOS HILLS January 7, 1998 L3497A TO: Susan Manca Planner TOWN OF LOS ALTOS HILLS 26379 Fremont Road Los Altos Hills,California 94022 SUBJECT: Supplemental Geotechnical Review RE: Malek/Enviro International,New Residence #254-97-ZP-SD-GD-VAR 11972 Rhus Ridge At your request, we have completed a supplemental geotechnical review of permit applications for site development using: • Response to Geotechnical Review (letter) prepared by GeoForensics, dated December 22, 1997. In addition, we have reviewed pertinent technical documents from our office files. DISCUSSION The applicant proposes to construct a single family residence near the crest of a ridge within the northeastern half of the property. In our previous review report (dated December 15, 1997), we recommended that supplemental septic leachfield evaluations be performed to address the potential for adverse seepage/slope instability impacts. CONCLUSIONS AND RECOMMENDED ACTION The Project Geotechnical Consultant has addressed the issues concerning septic leachfield design and concluded that the currently proposed leachfield locations are acceptable, the potential for surfacing of effluent is low, and leachfields should not have a detrimental affect on slope stability. The consultant has satisfactorily addressed the issues of our previous review and consequently we recommend geotechnical approval of permits for project construction with the following conditions: 1. Site Drainage Design - Prior to issuance of permits for project construction, detailed drainage design plans should be prepared. Discharge of concentrated water onto very steep slopes in the southwestern portion of the lot should be avoided because of potential erosion/slope stability impacts. Final site drainage design should be completed to the satisfaction of the Project Geotechnical Consultant and Town Engineer. Northern California Office Southern California Office 330 Village Lane 5245 Avenida Encinas • Suite A Los Gatos,CA 95030-7218 Carlsbad,CA 92008-4374 (408)354-5542 • Fax(408)354-1852 (760)931-2700 • Fax(760)931-1020 e-mail:losg@csageo.com e-mail:carl@csageo.com • Susan Manca January 7, 1998 Page 2 L3497A 2. Geotechnical Plan Review - The applicant's geotechnical consultant shall review and approve all geotechnical aspects of the development plans (i.e., site preparation and grading, site drainage improvements and design parameters for foundations and driveway) to ensure that his recommendations have been properly incorporated. The results of the plan review should be summarized by the geotechnical consultant in a letter and submitted to the Town Engineer for review and approval prior to issuance of building permits. This review has been performed to provide technical advice to assist the Town in its discretionary permit decisions. Our services have been limited to review of the documents previously identified, and a visual review of the property. Our opinions and conclusions are made in accordance with generally accepted principles and practices of the geotechnical profession. This warranty is in lieu of all other warranties, either expressed or implied. Respectfully submitted, COTTON, SHIRES AND ASSOCIATES,INC. TOWN GEOTECHNICAL CONSULTANT Ted Sayre Supervising Engineering Geologist CEG 1795 Patrick O. Shires Principal Geotechnical Engineer GE 770 POS:TS:rb COTTON, SHIRES & ASSOCIATES, INC. ENVIRONMENTAL DESIGN COMMITTEE NEW RESIDENCE EVALUATION ;v. Applicant's Name: Address: R/‘- /W Reviewed by: . -`1 G�Vie./c Date: /01 13' -7� Existing Trees: (Comment on size, type, condition, location with respect to building site. Recommended protection during construction.) . Proposed Grading: (Impact on water table, nearby vegetation. Erosion potential. All grading at least 10' from property line?) Creeks and drainage: (Should a conservation easement be recommended? Sufficient space between house and conservation easement for circulation. Will construction impact wildlife migration (bridges, fences)? Is there a need for removal of invasive species?) Siting_: (View impact: ridgeline, across valley, on neighbors. Will driveway impact neighbors' privacy (lights, noise)? Recommended mitigation 4� (height, color, landscape).) _ A0/"''-‘1 Com ' f, 01, fl 74--c,, 171'1" O er Comments: A5zr D it/o , �.��o kwa.c.k,,,A s4 to ENVIRO INTERNATIONAL Architects Safi/vat A. Malek C-7308 101 First Street. Suite 422. Los Altos. California 94022 Phone: 650/013-1580- 650/941-0503 FAX: 650/813-9295-650/948-5228 E-mail: samalek@aol.mrn November 18,1997 Re: 11972 Rhus Ridge-Request for Variance The Philosophy: To design and build a home that is sustainable and ecologically sound,featuring princi- pals of energy efficiency,envitonmental protection,resource efficiency and reduced toxicity. Once completed,the home shall be certified as an Earth Smart Home,(only 800 are completed or under construction nation wide). The Challenge: How to design and build a home that meets the above criterion realizing the nature of the site;mature oak trees,topography,accessibility,the shape of the property and the fabric of the surrounding community and its rich heritage. The Solution: 1.Design a home that fits in between the trees. According to the proposed design,only two oak trees are to be removed,and strictly to accommodate a safe driveway. All the other oaks(six) are to be removed because of poor condition. Some are hazardous. 2.Design a home that is purposely situated to flow with the contours of the site thus avoiding large cuts and retaining walls and,at the same time,allows for a driveway that is safe and graceful. A major section of the driveway is surfaced with interlocking pavers installed over base rock and sand. This allows for permeability. 3.Design an eclectic home with flat roofs and accents of tiled roofs,all are stepped down to follow the contours allowing interesting volumes and shapes without creating a large bulk. 4.Landscape the site to provide a park like setting with pathways,park benches and intimate patio spaces in between the trees,using a combination of gravel pathways and flagstone patios(In both cases set in sand).The garden walls are designed with ferns and native ground cover planted among the drystack fieldstone rubble. The findings for the Variance: It is important to note that the size of the home is 2989 s.f and the garage(only two cars) is 546 s.f.with a total MFA of 3535 s.f. (which is well within the"allowable"MFA of 4000 s.f).The request for variance is for additional MDA.In order to save as many treco as we are proposing and to avoid severe grading,at the same time offer a safe circulation,it became necessary to incorporate this design for the driveway,(2400 s.f.).to compensate for the size,we are proposing the interlocking pavers instead of an impervious surface. The patios(800 s.f.)are designed in intimate scale to minimize the need for additional MDA.To compensate for the additional square footage,we propose to use fieldstone set in sand,again,to avoid the introduction of impervious surfaces.Even the garden walls are in dry stack fieldstone to offer permeability. 1.Granting the Variance for the additional 1515 s.f.of MDA affords the adjoining neigh- bors a pleasing,graceful design that is un-obtrusive and seduded.It also preserves the nature of the area.In this regard,granting the Variance offers the same privileges enjoyed by other properties in the vicinity. 2.That upon the granting of the variance,the intent and purpose of the ordinance will still be served and the recipient of the variance will not be granted special privileges not enjoyed by other surrounding property owners. 3.That the granting of the Variance will not be materially detrimental to the public wel- fare or injurious to the property,improvements or uses within the immediate vicinity and within the same zoning district. 4.That the Variance will not allow a use or activity which is not expressly authorized by the Zoning Ordinance. Re: 11972 Rhus Ridge - Request for Variance Schedule of homes in the area Address Size (according to Assessors Records) 11970 Rhus Ridge 2784 s.f. 11930 Rhus Ridge 5470 s.f. 11950 Rhus Ridge 1759 s.f. 11920 Rhus Ridge 3548 s.f. 11910 Rhus Ridge 3482 s.f. 11989 Rhus Ridge 1928 s.f. 12001 Rhus Ridge 2088 s.f. 25263 La Loma 3400 s.f. 25265 La Loma 3783 25201 La Loma 2054 s.f. 25215 La Loma 2865 s.f. 25223 La Loma 2289 s.f. 25259 La Loma 3865 S.F. 25225 La Loma 4235 s.f. 25245 La Loma 3089 s.f. 11499 Summitwood 3671 s.f. 11511 Summitwood 4408 s.f. 25255 La Loma 2577 s.f. 25295 La Loma 3659 s.f. 25785 Bassett Lane 2876 s.f. 25700 Bassett Lane 2342 s.f. 25725 Bassett Lane 4327 s.f. A RECEIVED JAN 211998 11970 Rhus Ridge Road Los Altos Hills, CA 94022 TOWN OF LOS ALTOS HILLS January 17, 1997 Los Altos Hills Town Planning Commission Town Hall 26379 Fremont Rd Los Altos Hills, CA 94022 cc: Safwat Malek Dear Commissioners: We are the owners of the house and lot immediately adjacent to the proposed house development by Mr. Safwat Malek at 11972 Rhus Ridge Road. In addition, we hold an easement over Mr. Malek's driveway for access to our house, because our house is the original structure that Mr. French, who owned both properties together, lived in for 35 years. Mr. Malek has asked us to document our comments concerning his proposal. We hope that these comments will be helpful to you in your deliberations or modifications concerning his proposal. The important factor for us concerning this proposal is the preservation of the existing character of the neighborhood. The houses here on the top of Rhus Ridge were all built in the early 1960's, when Mr. Duveneck created this housing area (at the same time that he created the Open Space regions). All five houses at the top of the hill are still owned by either the original or secondary owners! Thus, there has been an amazing longevity and consistency to the character of this neighborhood, which we hope can be maintained through careful development. We believe the significant characteristics of this hill are: - A heavily-wooded environment. - Privacy through extensive natural screening, so that houses are hidden from each other. - Sensitivity to the woods and open space areas, including numerous trails winding through the properties. - Simple homes, which, due to their 1960's heritage, are either international or basic style. These factors lead us to the following comments on Mr. Malek's proposal: 1 Size, location, and style of house Because it is being built as a "spec" house, we recognize that it needs to be of a certain size for market reasons. Because the house is located away from ours, we are not as heavily impacted by the size of the house as is the other adjacent neighbor, Mr. Joe Goodman. We do appreciate that Mr. Malek has gone to great lengths to have the house work with the hill, and that it is a single story house. Mr. Malek's plan seems to preserve as many of the trees (many of which are heritage oaks) as is possible for a house of that size. We are assuming (and insisting) that the landscaping plan will prevent the house from being seen directly from our house, so the Mediterranean style will not be overbearing on the property. Screening This is extremely important for us. The majority of our property is natural, undeveloped woods,.and thus the value of our property is predicated on this . . privacy (which is why we purchased this land). Mr. Malek has been quick to address our screening issues by planning more screening along the driveway area, and we look forward to seeing the details of a complete screening plan that addresses visibility along the entire property line. Coverage & Driveway Mr. Malek is proposing a variance of some 1400 square feet. We understand that the Fire Department has asked Mr. Malek to add more driveway area (both in width and in additional turnaround areas) than he originally intended, and that they also asked him to use concrete for the driveway. For any variance that is due to these unanticipated requirements, we understand the need to exceed the MDA. Our house is in a similar situation in that, despite it being a large lot, much of it is too steep to contribute useful MDA. Because his driveway also serves as our driveway, it is important to us that it be aesthetically pleasing and help preserve the natural look of the area. Thus;if possible, we would like to see Mr. Malek permitted to use his preferred driveway surface, the interlocking stone surface, along the entire driveway. (We understand that the fire department has requested concrete.) We would also like to see him allowed to use a narrower driveway as he originally planned, if possible. Setbacks We will be particularly sensitive to any development in the setback areas, since screening is so important, so we hope that driveway and turnaround areas can be kept to a minimum in the setback areas. 2 • Pathways/Trails There is an existing trail that runs through all 4 house lots on the hill, and which leads into many other trails in the open space area. We appreciate that Mr. Malek has preserved both this trail and the lookout area on the back side of the hill. In summary, we at present have no major objections to the plans that we have seen. As the plans progress, we will monitor the issues mentioned above. We recognize and appreciate that Mr. Malek has worked to preserve the trees and trails, and has worked to address any of the neighbors' issues as well. We look forward to having that continuing throughout the development process. Sincerely, c4r ;f14-"4-' Roger & Elizabeth Spreen • 3 r.. GJ The Town of Los Altos Hills Planning Department, Re:Application for Site Development and Variance,11972 Rhus Ridge I have reviewed the plans,elevations,site development plan,landscape plan and sewage disposal plan for the subject project. I support the application. Best regards, Name Signature Date Address 'PA: VAx/A- ,G ,011 n. 407 5- 67*r LA,.. 44// rz_ t4 A ely:eat-6Yetie411/ r5n7 Tetxrt be 1 `\_)...... - I ": "„L it //,c/97 / /col MW--��: Q • Printed on recycled paper The Town of Los Altos Hills Planning Department, Re:Application for Site Development and Variance,11972 Rhus Ridge I have reviewed the plans,elevations,site development plan,landscape plan and sewage disposal plan for the subject project. I support the application. Best regards, Name Signature Date Address ���.�;f1. /C '-e'74/3 f! L /5-icv-rt / I/ 95'f 14/tc.f1-i,"i .7 v EA Z =I-Ad L 9 24-0-LI f �� Untne' L L'_?.¢x Printed on recycled paper A-4}-ctdnry-o-v,* CONTRACTOR'S#651341 •a JAMES M.MCCLENAHAN •�^` �' WALTER J.LAWRENCE GARY F.ARMSTRONG DAVID F.MOORE S.P. McCLENAHAN CO., INC . JOHN H.MCCLENAHAN GENE K.PEGLOW ARBORICULTURISTS #1 ARASTRADERO ROAD.PORTOLA VALLEY,CA 94028 TELEPHONE(415)326-8781 FAX(415)854-1267 October 6, 1997 Enviro International Attention: Mr. Safwat Malek 101 First Street, Suite 422 Los Altos, California 94022 RE: Proposed Building Site Rhus Ridge Los Altos Hills, California Dear Mr. Malek: As requested, I inspected trees at the above referenced site to determine present condition, impact of site improvements and provide recommendations for tree preservation. For purposes of identification, trees were previously tagged with numbered aluminum markers. In determining Tree Condition', several factors have been considered which include: (1) Rate of growth over several seasons; (2) Structural decays or weaknesses; (3) Presence of disease or insects; and (4) Life expectancy. The following guide for interpretation of'Tree Condition' as related to 'Life Expectancy' is submitted for your information. 0 - 5 Years = Poor 5 - 10 Years = Poor to Fair 10 - 15 Years = Fair 15 - 20 Years = Fair to Good 20 + Years = Good Enviro International Page 2 October 6, 1997 Tree #524: Species: Coast Live Oak (Quercus agrifolia) multi trunk 18.8, 16.5, 17.6" diameter @ 4-1/2' above grade Condition: Good Observation: Foliage is of uniform size and color and indicates normal tree vitality. Trunk bifurcation's at 2' and 3' provide an inherent structural defect. The proposed leach line ends 10' from the tree and minimal impact to tree environment is expected. Prognosis: With adoption of preservation measures prognosis is considered most favorable. Tree #336: Species: Coast Live Oak 14.8" diameter @ 4-1/2' above grade Condition: Good Observation: Foliage is of uniform size and color and indicates normal tree vitality. A trunk bifurcation at 7' provides an inherent structural defect. Proposed leach line ends 6' from the tree. At this distance buttress roots will be preserved with minimal impact to lateral root environment. Prognosis: Favorable with adoption of preservation measures. Tree #324: Species: Coast Live Oak 22.8" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is of uniform size and color and indicates normal tree vitality. Two decay columns at 3' on west side and 6' on the east side weaken tree structure. Proposed leach line encroaches no closer than 8'. Hand digging to an approximate 30" depth is required when within 12' of trunk. Prognosis: Favorable with adoption of preservation measures. Enviro International Page 3 October 6, 1997 Tree #518: Species: Coast Live Oak • 14.2" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is of uniform size and color and indicates normal tree vitality. Proposed leach line encroaches no closer than 8'. At this distance buttress roots will be preserved with minimal impact to lateral root environment. Prognosis: Favorable with adoption of preservation measures. Tree #327: Species: Coast Live Oak 12.2" diameter @ 4-1/2' above grade Condition: Poor to Fair Observation: Foliage is slightly sparse from competition with poison oak vine. Tree is to be removed for proposed leech line construction. Tree #327a: Species: Coast Live Oak 8.9" diameter @ 4-1/2' above grade Condition: Poor to fair Observation: Foliage is sparse and the tree leans to the north. Excavation on northerly side should not encroach within 4-1/2' of trunk. Buttress roots will be preserved and impact to lateral root area will not exceed 20%. Prognosis: Favorable, with adoption of preservation measures. Enviro International Page 4 October 6, 1997 Tree #327b: Species: Coast Live Oak 8.0" diameter @ 4-1/2' above grade Condition: Very poor Observation: Foliage is very sparse, extensive trunk deterioration and exaggerated lean increase hazard potential. Tree retention is considered a calculated risk and removal is recommended. Tree #519: Species: Coast Live Oak (M.T.) 11.0, 9.8" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is sparse and indicates a decline in tree vitality. V-crotch formations at 1' and 4' provide an inherent structural defect. A cavity from previous failed northerly standard also weakens tree structure. Removal of 3" diameter low limb is needed for clearance and a cable should be installed between remaining two standards for support. Proposed leach lines encroach 7' on southwest side and 8' on west and east sides. Hand digging of trenches to an approximate 30" depth is required when within 8' of trunk. Prognosis: Favorable, with adoption of preservation measures. Tree #282: Species: Coast Live Oak 15.0" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is of uniform size and color and indicates normal tree vitality. A bifurcation at 7' provides an inherent structural defect. Proposed leach lines run 10' to northeast and northwest sides. At this distance, impact to buttress roots is minimal and damage to lateral roots is sustainable. Prognosis: Favorable, with adoption of preservation measures. Enviro International Page 5 October 6, 1997 Tree #282a: Species: Coast Live Oak 7.9" diameter @ 4-1/2' above grade Condition: Poor to Fair Observation: The tree leans west and has a trunk bifurcation at 3' which weakens tree structure. It also crowds the adjacent oak. The proposed leach line encroaches within 2' of the trunk. Remove to enhance growing environment of larger adjacent oak. Tree#299: Species: Coast Live Oak 35.0" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is of uniform size and color and indicates normal tree vitality. Small areas of bark deterioration are not considered significant at this time. The proposed driveway encroaches 8' from the trunk. Grading within 12' of the trunk must be accomplished by hand to an approximate 30" depth. Prognosis: Favorable, with adoption of preservation measures. Tree #299a: Species: Coast Live Oak 7.9"diameter @ 4-1/2' above grade Condition: Poor to Fair Observation: The tree leans severely to the north and needs to be removed for the proposed driveway. Tree #299b: Species: Coast Live Oak 7.5" diameter @ 4-1/2' above grade Condition: Poor Observation: The tree leans to the north and needs to be removed for the proposed driveway. Enviro International Page 6 October 6, 1997 Tree #299c: Species: Coast Live Oak 6.9" diameter @ 4-1/2' above grade Condition: Dead Observation: Small dead stump with extensive decay should be removed. Remove for proposed driveway. Tree #299d: Species: Coast Live Oak 26.5" diameter @ 4-1/2' above grade Condition: Dead Observation: Remove to eliminate hazard. Tree #10: Species: Coast Live Oak 10.1" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is of uniform size and color and indicates normal tree vitality. Proposed driveway encroaches to within 4' of the trunk. Poison oak vines should be removed from the tree. At this distance buttress/sinker roots will be preserved and sufficient root area will remain to sustain tree vitality. Prognosis: Favorable, with adoption of preservation measures. Tree #11: Species: Coast Live Oak 16.0" diameter @ 4-1/2' above grade Condition: Dead Observation: Dead stump. Recommend removal. Enviro International Page 7 October 6, 1997 Tree #12: Species: California Bay Laurel (Umbellularia califomica) M.T.+ 9.8,7.5" diameter @ 4-1/2' above grade Condition: Fair to Good Observation: Foliage exhibits normal tree vitality. However, structure is weak at low trunk bifurcation. The tree will be removed for driveway construction. Tree #320: Species: Coast Live Oak 20.1" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is typical of the species and indicates normal tree vitality. The proposed driveway encroaches to within 5' on the west side. Excavation or grading must be accomplished by hand when within 10' of the trunk. Initiate a pruning and fertilization program to enhance prognosis. Prognosis: Favorable, with adoption of preservation measures. Tree #13: Species: Coast Live Oak 11.1" diameter @ 4-1/2' above grade • Condition: Poor to Fair Observation: Foliage is sparse and the tree leans to the east. The tree is located approximately 3' from the proposed parking area. Removal is recommended to accommodate parking area. Tree #14: Species: California Bay Laurel 10.6" diameter @ 4-1/2' above grade Condition: Fair to good Observation: Foliage is typical of the species and indicates normal tree vitality. The tree is located at the edge of the proposed parking area and should be removed. Remove to accommodate parking area. Enviro International Page 8 October 6, 1997 Tree #377: Species: Coast Live Oak 11.7" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is typical of the species and indicates normal tree vitality and structure is sound. The tree is located in the middle of proposed driveway. The tree should be removed to accommodate proposed driveway. Tree #581: Species: Coast Live Oak 19.3"diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is typical of the species and indicates normal tree vitality. Tree structure is sound. Proposed parking space encroaches 8' from the trunk on the east side. Excavation and grading within 8' of the tree must be accomplished by hand digging, to minimize injury to lateral roots. Initiate root crown restoration, fertilization and crown restoration program for preservation. Prognosis: Favorable, with adoption of preservation measures. Tree #525: Species: Coast Live Oak 10.9" and 19.6 (dead) diameter @ 4-1/2' above grade Condition: Poor/ hazardous Observation: Structure is weak from previous failure and extensive decay. The tree is located 4' below proposed driveway. Retention is a calculated risk and removal is recommended. Enviro International Page 9 October 6, 1997 Tree#381: Species: Coast Live Oak 10.2" diameter @ 4-1/2' above grade Condition: Fair to Good Observation: Foliage is typical of the species and indicates normal tree vitality. Tree structure is sound with slight lean. Proposed home encroaches approximately 3' from the trunk on the north side. At this distance, hand digging of footings to an approximate 30" depth is required. Prognosis: Favorable, with adoption of preservation measures. Tree#521: Species: Coast Live Oak (M.T.) 12.6, 6.1" diameter @ 4-1/2' above grade Condition: Fair to Good Observation: Parking area will encroach to with 5' of trunk on the northeast side and driveway will encroach to within 5' of trunk on the southeast side. At these distances buttress roots will be preserved and impact to lateral root environment will not exceed 50%. Sufficient root area will remain to sustain tree vigor. Prognosis: Favorable, with adoption of preservation measures. Tree#317: Species: Coast Live Oak 18.2" diameter @ 4-1/2' above grade Condition: Poor to Fair Observation: Foliage is sparse, blighted and indicates, root stress. Encroachment to within 8' of trunk on the north side (6' cut) will allow preservation of buttress roots and sufficient root area will remain to sustain tree vigor. Pathway construction on north side will have minimal impact to tree environment. Prognosis: Tree may not respond to preservation measures. Prognosis is questionable. Enviro International Page 10 October 6, 1997 Tree #329: Species: Coast Live Oak 18.7" diameter @ 4-1/2' above grade Condition: Fair Observation: Tree has grown to a natural westerly lean. Proposed pier and grade beam foundation will encroach no closer than 7' from trunk. Impact to root environment is expected. At this distance, hand digging of footings to an approximate 30" depth is required. Prognosis: Favorable, with adoption of preservation measures. Tree #338: Species: Coast Live Oak 17.5" diameter @ 4-1/2' above grade Condition: Fair to Good Observation: Foliage is typical of the species and indicates normal tree vigor. Climbing hooks had been used for prior tree access and trunk injuries exhibit closure. Proposed pier and grade beam foundation will encroach no closer than 6' from trunk. At this distance, hand digging of footings to an approximate 30" depth is required. Prognosis: Favorable, with adoption of preservation measures. Tree #15: Species: Coast Live Oak 11.5" diameter @ 4-1/2' above grade Condition: Poor to Fair Observation: Foliage is sparse and dieback indicates exposure to environmental stress. Tree has grown to a southerly lean over proposed house. Recommend tree removal. Enviro International Page 11 October 6, 1997 Tree #295: Species: Coast Live Oak 20.2" diameter @ 4-1/2' above grade Condition: Fair to Good Observation: Foliage is typical of the species and indicates normal vitality. Tree structure is sound with no visible signs of decay. Proposed foundation construction will encroach to within 10' of trunk and no impact to tree environment is expected. Prognosis: With adoption of preservation measures, prognosis is considered favorable. Tree #333: Species: California Bay Laurel 15.7" diameter @ 4-1/2' above grade Condition: Good Observation: Foliage is typical of the species and indicates normal vitality. Tree structure is sound with no visible signs of decay. Proposed pier and grade beam foundation will encroach no closer than 10' from trunk and minimal impact to root environment is expected. Prognosis: With adoption of preservation measures, prognosis is considered favorable. Tree #339: Species: Coast Live Oak 13.3" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is typical of the species and indicates normal vitality. Tree leans in a southeasterly direction. Proposed pier and grade beam foundation will encroach no closer than 5' from trunk and impact to root environment is expected. Prognosis: With adoption of preservation measures, prognosis is considered questionable. Enviro International Page 12 October 6, 1997 Tree #323: Species: Coast Live Oak 12.6" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is sparse and dieback indicates exposure to environmental stress. Construction is beyond tree environment and no impact to tree environment is expected. Prognosis: Favorable, with adoption of preservation measures. Tree #331: Species: California Bay Laurel 17.9" diameter @ 4-1/2' above grade Condition: Poor to Fair Observation: Foliage is typical of the species. Wood decay has encompassed more than 30% of the root crown and the trunk lean increases hazard potential. Recommend thistree be removed. Tree #514: Species: Coast Live Oak (M.T.) 17.0, 11.4, 16.2" diameter @ 4-1/2' above grade Condition: Poor to Fair Observation: • Foliage is sparse and stunted with extensive structural decay. Tree is located at building footprint. Tree is potentially hazardous and will be removed for construction. Enviro International Page 13 October 6, 1997 Tree #517: Species: Coast Live Oak (M.T.) 15.1, 16.2" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is slightly sparse and indicates a lack of tree vigor. Proposed home will encroach to within 5' on the north and east sides. Home excavation, to an approximate 6' depth will impact buttress/sinker roots. At this distance, hand digging of footings to an approximate 30" depth is required. Prognosis: Questionable, with adoption of tree preservation measures. Tree #16: Species: Coast Live Oak 11.1" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is typical of the species and indicates normal tree vigor. Tree structure is sound and the northerly lean has not increased hazard potential. Proposed home excavation to within 5' of trunk will have significant impact on tree environment. At this distance, hand digging of footings to an approximate 30" depth is required. Prognosis: Favorable, with adoption of preservation measures. Tree #509: Species: Coast Live Oak 12.9" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is typical of the species and indicates normal tree vigor. Tree structure is sound and the southwesterly lean has not increased hazard potential. Proposed home will encroach to within 5' on the up hill side and impact to tree environment is expected. Prognosis: With adoption of preservation measures, prognosis is fair. Enviro International Page 14 October 6, 1997 Tree #499: Species: Coast Live Oak 12.0" diameter @ 4-1/2' above grade Condition: Poor Observation: Foliage is sparse and significant dieback throughout the canopy indicates advance decline. Proposed home construction will encroach to within 4' and impact to tree environment is expected. This tree will not respond to preservation measures and removal is recommended. Tree #508: Species: Coast Live Oak 15.8" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is typical of the species and indicates normal vitality. Proposed home will encroach to within 12' of trunk on the easterly side and minimal impact to tree environment is expected. Prognosis: With adoption of preservation measures, prognosis is considered favorable. Tree #594: Species: Coast Live Oak (M.T.) 15.8, 12.8" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is typical of the species and indicates normal vigor. Proposed home will encroach to within 14' on the east side and minimal impact to tree environment is expected. Prognosis: With adoption of preservation measures, prognosis is considered favorable. Enviro International Page 15 October 6, 1997 Tree #522: Species: Coast Live Oak (M.T.) 18.4, 15.7, 12.5, 15.7" diameter @ 4-1/2' above grade Condition: Fair Observation: Foliage is typical of the species and indicates normal vitality. Tree is structure is sound and crotch cavity has not compromised structural integrity. Proposed home will encroach to within 10' on the easterly side and minimal impact to tree environment is expected. Prognosis: With adoption of preservation measures, prognosis is considered favorable. Tree #275: Unable to locate on site. Per Site Plan, minimal impact to tree environment is expected. With adoption of tree preservation measures, prognosis is considered fair. • LEECHFIELD EXPANSION Leech lines have been located no closer than within 10'of trunks. Leech line #1 is located on the westerly side (down slope) of existing trees and leech line #2 ends no closer than within 10'of trunks. At these distances, hand digging will not be required and minimal impact to tree environments is expected. With adoption of preservation measures, the prognosis is considered favorable. ************************************** • "` sa• Ib ,. • Q • J TOWN OF LOS ALTOS HILLS PLANNING DEPARTMENT 26379 Fremont Road•Los Altos Hills, California 94022 • (415) 941-7222 •FAX(415) 941-3160 WORKSHEET #2 EXISTING AND PROPOSED DEVELOPMENT AREA AND FLOOR AREA TURN IN WITH YOUR APPLICATION • — PROPEK'1'Y OWNER'S NAME ► -,1‘1 ,(1,0 li\SCWAc(cDid pki./ PROPERTY ADDRESS 1191 Z g_ s• g-1D&1 CALCULATED B Y S T ivi Pr L Y-- DA IE t 1 / 20 I T 7 1. DEVELOPMENT AREA (SQUARE FOOTAGE) Existing Proposed Total (Additions or Deletions) A. House and Garage (from Part 2.A.) '3535 3 5 35 B. Decking — — C. Driveway and Parking(iIrrel2Locr,iJG -05016/16) (Measured 100'along centerline) ' SA's!o — "Z--4 00 z400 D. Patios and Walkways(r=w.;fToAe_ i+,1 .RSD) — - a59_i 0-SO E. Tennis Court — — — _ F. Pool and Decking — _ — — G. Accessory Buildings (from Part B) -- H. Any other coverage - rt. -- Coo - ..Lou TOTALS _ W--L-1- C.0. 4S Maximum Development Area Allowed-MDA (from Worksheet#1) 5220 A. AtRG " ILUC14 ACL`71 4t-7icD oP- __(,DOSE i5 JOT INCL�.4.138 Be-CA-USE F "nits u5tE; qq��E�, ftV-RIFT PaJciS w/ r9A t L, 9L I7 rii" '12 -eU,-lO CaiJ 7• CI°t°GDV2,f � 2. FLOOR A EX (SQUARE FOOTAGE) Existing _ Proposed Total (Additions or Deletions) A. House and Garage • a. 1st Floor(MM (..e/61-) --- 2 2°( 2_929 b. 2nd Floor — -- _ c. Attic and Basement — — d. Garage5 4 6 - 5 y-& B. Accessory Buildings a. 1st Floor _ — _ — — b. 2nd Floor -- — c. Attic and Basement — — TOTALS — 3 5 3 5 35 3 >' Maximum Floor Area Allowed -MFA (from Worksheet#1) 4 000 . t TOWN USE ONLY CHECKED BY DA 1'E l 19q – Revised 2/26/96