Loading...
HomeMy WebLinkAbout3.4 W TOWN OF LOS ALTOS HILLS April 22, 1998 Staff Report to the Planning Commission RE: SITE DEVELOPMENT PERMIT, CONDITIONAL DEVELOPMENT PERMIT, AND VARIANCE TO ALLOW ENCROACHMENT INTO SETBACKS, DEVELOPMENT AREA AND FLOOR AREA IN EXCESS OF THE MAXIMUM ALLOWABLE, AND REDUCED SIZE OF PARKING SPACES; FOR AN ADDITION AND REMODEL; LANDS OF HUANG; 27760 SHERLOCKK ROAD; #250-97-ZP-SD-GD-CDP-VAR. FROM: Susan Stevenson, Planner��S APPROVED BY: Curtis S. Williams, Planning Director RECOMMENDATION That the Planning Commission: Approve the requested Site Development Permit and Variance, subject to the recommended conditions of approval. BACKGROUND The subject property is located at the south side of Sherlock Road, at the corner of Moody Road and Sherlock Road. The property is bounded by Moody Road on 2 sides and is intersected by Sherlock Road at the north end of the property. A 25 foot wide private driveway easement bounds the east side of the property, with half of the easement on the subject lot. There is a small house and garage on the property. The garage is located in the setback, along Sherlock Road. The property is populated with several oaks, including several heritage oak trees and contains areas with slopes greater than 30 percent. CODE REQUIREMENTS As required by Section 10-1.1104 of the Zoning Ordinance, this application for an addition has been forwarded to the Planning Commission for review and approval. Criteria for review from the Site Development Ordinance include grading, drainage, building siting,pathways, landscape screening and outdoor lighting. Zoning Code review encompasses compliance with floor and development area requirements, setbacks, height and parking. The evaluation of the Variance should include many of the same items, concurrently evaluating the physical site conditions which result in an undue hardship on the property. The approval of a Variance also requires that certain findings be approved by the Planning Commission. Staff has prepared findings for approval (see Attachment #2) for the Commission's review. The evaluation of the Conditional Development Permit should include the consideration of the size and design of the project with respect to the size, shape and topography of the site. The approval of a Conditional Development I. Planning Commission Lands of Huang April 22, 1998 Page 2 Permit requires that findings be approved by the Planning Commission. Staff has prepared findings for approval (see Attachment#3) for the Commission's review. DISCUSSION Site Data: Gross Lot Area: 1.08 acres Net Lot Area: .612 acres* Average Slope: 29.7% Lot Unit Factor: .351 *Net area based on future 10 foot right of way dedication along Moody Road. Floor Area and Development Area: Area Maximum Proposed Existing Increase Left Development 2,672 3,376 1,317 +2,059 0 Floor 1,760 1,896 1,317 + 579 0 Site and Architecture The applicant is requesting approval of a site development permit for a 498 square foot single story addition and a new 452 square foot two-car garage. The existing garage, located close to the north property line is proposed to be removed, so that the net addition to the floor area would be 579 square feet. The addition is designed to step down with the natural slope of the building site and the roofline follows the natural grade as well. The existing house is located at the flattest portion of the lot, with the addition stepping down 3 feet from the main building pad. A 370 square foot deck is proposed at the back side of the addition to obtain some outdoor living area. The height of the addition would be 19.5 feet from the building pad and 13 feet at the south side of the new addition. The maximum height of the new residence will be 201/2 feet as measured from the natural grade. Story poles have been placed on the site for the Commission's review. Proposed exterior materials include stucco siding and wood trim with a stone base, and an architectural shingle roof The addition and the new garage have been designed with a minimal height and the roof is designed to slope with the natural slope of the lot to lessen visual impacts of the additional areas. Ten skylights are proposed with the residence. Exterior colors have not yet been chosen. Staff will review proposed colors for conformance with the Town's adopted color board,prior to the painting of the residence. Planning Commission Lands of Huang April22, 1998 Page 3 Driveway &Parking The proposed driveway would be 14 feet wide at the entrance of the property. Two parking spaces have been proposed within the west setback of the property, with substandard dimensions (81/2 feet by 15 feet). The spaces would be located up to the new property line after the dedication of 10 additional feet of right of way along Moody Road. Both the location of the spaces and the substandard size of the spaces require variances from the Code (Section 10-1.505 and Section 10-1.601)." The existing garage is located within the Sherlock Road right of way and is proposed to be demolished. The new 2 car garage would be located further into the property (15 feet from the Sherlock Road right of way) although it would still require a variance as it is closer than 30 feet from the edge of the right of way. The interior of the garage would have 2 standard size parking spaces. Turnaround is not provided on the site, contrary to Town policy. It should be noted, however, that the existing parking on the site also does not include the turnaround area required by the Town and that the proposal will increase parking available on the site. Parking upgrades to meet own standards have typically not been required for minor additions (less than 900 square feet). Outdoor Lighting Outdoor lighting is shown on the floor plans (sheet A-2). Minimal lighting is requested, with 1 light per exit. Staff has included the standard condition (#10) for outdoor lighting, requiring that fixtures be downshielded with a maximum of one fixture per exit except at the garage and front entry. The applicant has submitted lighting specifications (attachment#12) indicating that fixtures will be downshielded to mitigate visibility. Trees &Landscaping There are numerous trees and shrubs that provide screening of the site from Moody Road. Condition of approval #4 requires that the trees within the vicinity of the construction be fenced for protection and preserved. One oak tree is located directly outside the footprint of the proposed addition (18 inch shown on the site plan, but referenced as a 10-12 inch oak in the arborist's letter) and is proposed to be saved although the arborist's letter indicates that it is in poor condition. An 18 inch oak which is located in the center of the addition is proposed to be removed. Staff has added a condition (#2) that 3 native oaks be planted down slope of the proposed deck to replace the oaks which will be removed with the construction. Any planting required for screening or erosion control will be required to be planted prior to final inspection. Planning Commission Lands of Huang April 22, 1998 Page 4 Conservation Easement There are several areas on the site which have slopes greater than 30 percent. Staff has included a condition of approval requiring that the property owner grant a conservation easement to the Town over all undeveloped portions of the property where the slope is 30% or greater. The conservation easement shall be worded to allow for the construction and maintenance of the approved septic system for the property. Right of Way Dedications The property is bounded on 3 sides by roads, including Moody Road along the south and west property lines. This section of Moody Road has an existing 20 foot right of way half width. Although the addition would result in a net increase of less than 900 square feet of floor area, a conditional development permit allows the Town to apply conditions to protect safety and public welfare. Staff has therefore included a requirement to dedicate an additional 10 feet of right of way for Moody Road (condition#15). The lot is bounded along the north side by Sherlock Road, with an existing 20 foot private road easement. The Town has requested other property owners along Sherlock Road to dedicate at least a 30 foot half width for the road where a new residence or major addition is proposed. Staff has consulted with the Town attorney regarding the nexus for requiring additional right of way when the net addition is under 900 square feet, and believes that requiring both dedications would be excessive and that the dedication of the additional right of way for Moody Road would be appropriate. Staff has, however, required that the applicant offer the Sherlock Road right of way for public dedication (condition #16) which would not affect the net lot size or create further nonconformity. The applicant has calculated the MDA and MFA based on the dedication of the additional 10 feet of right of way for Moody Road and excluding the 20 foot easement for Sherlock Road and the 12.5 foot strip of road easement along the eastern property line. Variance The applicant is proposing to demolish the existing garage, which is located within the Sherlock Road right of way and to add a garage to the residence. The structure would be 16 feet from the Sherlock Road right of way. The addition to the residence would be partially located within the front setback after the dedication of 10 feet of right of way along Moody Road. The subject lot is constrained by the roadways on 3 sides of the property and a private access easement along the 4th side of the property. The requirement for additional right of way along Moody Road increases the setbacks on the lot and the shape of the lot makes it very difficult to propose development completely out of the required setbacks. Planning Commission Lands of Huang April 22, 1998 Page 5 All of the 4 required parking spaces are also located within the setback, requiring a Variance. Two of the required spaces do not meet the dimensions required per Section 10-1.601 Of the Zoning Ordinance. There is limited area on the lot to provide parking and turnaround. Increasing the size of the parking spaces would increase the amount of pavement in the setbacks. The location of the spaces as shown could not be increased without encroaching into the area 10 feet from the existing Moody Road right of way, which would require a variance for grading within 10 feet from the property line and would encroach into the future road right of way. The applicant has designed the additions and remodel to the residence to fit into the site and the immediate neighborhood. The applicant's proposal for the additions to the floor area exceed the MFA by only 93 square feet and the increase in the development area would be 639 square feet over the MDA. The development would fit into the site and would not be intrusive to the neighbors. The total proposed square footages would be well below the 5,000/4,000 square foot minimums allowed for lots with a L.U.F. in excess of 0.50 and considerably less than what has been recently approved for other conditional development lots. With reference to theshape of the lot and the numerous access easements on the lot, and the site topography, staff has prepared findings to approve variances to allow the increases in the floor and development area, encroachments into setbacks, and reduced parking space size. Conditional Development Permit As the L.U.F. for this property is less than 0.50, a conditional development permit is required by Section 10-1.1107(3) of the Zoning Code. In order to grant a conditional development permit,the Commission must make four findings specified in the Code. These permits are highly discretionary, and allow the Commission to set maximum floor and development areas for these highly unusual lots. Conditional development permit findings relate to the adequacy of the site to accommodate the proposed project, creation of a harmonious project in relation to the site topography and surroundings, minimizing alteration of the natural landscape, and compliance with regulations of the Site Development Ordinance. Attachment 3 outlines proposed findings for approval of the conditional development permit for the addition and changes to the driveway configuration. Staff believes that the site can readily accommodate the addition, as it is minimal in size and would not encroach into setbacks which are shared with neighbors. The 557 square foot addition can be screened from the roadway and neighboring properties and there would be minimal alteration of the existing natural slope and significant vegetation. The project would be fit into the character of the area reduces the amount of development located within the setbacks, and improves the on site parking. Planning Commission Lands of Huang April 22, 1998 Page 6 Grading & Drainage The residence and parking areas have been located at the most level area of the lot. The additions would step down with the changes in elevation. The maximum cut and fill for the residence meets the Town's grading guidelines except for a small portion (<50 square feet) of the garage and addition which is up to 41/2 feet above natural grade. The proposed deck at the rear of the house would be a maximum of 8 feet above natural grade (note that the section shows an area of the deck located 6% feet above the grade). The deck would have a 10 foot wide dimension, making it difficult to lower the deck and add steps and maintain usable outdoor area. The deck is proposed to be constructed on piers, rather than a retaining wall, which would allow planting to grow under and around the deck to mitigate its visibility. Staff has added language to condition #2 requiring that special attention be given to planting around the deck to minimize visibility from off site. The Engineering Department has reviewed the plans and has recommended conditions of approval as specified in Attachment #1. Drainage is designed to sheet flow around the house and driveway. The Engineering Department will review and approve the fmal drainage plan prior to acceptance of plans for building plan check. Final "as-built" grading and drainage will be inspected by the Engineering Department, and any deficiencies will be required to be corrected prior to final inspection. Septic System The septic system for the residence has been designed at the northeast portion of the lot, within 3 feet of the Sherlock Road easement. The county health department and the Town's geotechnical consultant have reviewed the plans and have preliminarily approved the location of the system. It should be noted that the existing septic system does not meet the health department's standards and a new septic system is required regardless of the approval of the additions. The septic system is limited in size and the maximum addition to livable floor area is 500 square feet, therefore, no additions would be permitted by the health department after this addition is completed. Geotechnical Review The Town's geotechnical consultant had some initial concerns regarding the possible detrimental effect of the leachfield on the existing slope. The applicant's geotechnical consultant has addressed this concern and Cotton, Shires and Associates have consequently prepared conditions of approval for the project as designed (see Attachment #1). Planning Commission Lands of Huang April22, 1998 Page 7 Fire Department Review The Santa Clara.County Fire Department reviewed the plans and has determined that the flow capacity of the nearest fire hydrant will not be adequate for a home of the proposed size. The applicant would be required to work with the Fire Department to provide fire hydrants and/or a fire sprinkler system to meet the Fire Department's requirements. The recommendations have been included as conditions in Attachment#1. Committee Review The Pathways Committee has requested that the applicant dedicate a pathway easement over the existing 20 foot wide Sherlock Road right of way. Due to the size of the addition, the Town may request the pathway dedication but may not generally require the dedication as part of the approval. As there is some added discretion associated with requests for conditional development permits and variances, however, staff has included the pathway requirement as condition #21. The Environmental Design Committee commented that the proposed skylights should be flat and non-reflective. Conclusion The proposed additions have been designed around the constraints of the lot and the property would have minimal outdoor living area. The variance to exceed floor area and development area appears to be appropriate due to the size and configuration of the additions and parking areas. The variance to encroach into the setbacks also appears to be appropriate due to the configuration of the lot and the additional right of way required with the project. Staff is available to answer any questions that the Commission or the public may have. , Planning Commission Lands of Huang April 22, 1998 Page 8 ATTACHMENTS 1. Recommended conditions of approval 2. Recommended findings for the Variance 3. Recommended findings for the Conditional Development Permit 4. Comments from Santa Clara County Fire Department, dated March 11, 1998 (two pages) 5. Letter from Cotton, Shires and Associates, dated April 14, 1998 (two pages) 6. Pathways Committee evaluations, received March 31, 1998 (one page) 7. Environmental Design & Protection Committee evaluations, received March 9, 1998 (one page) 8. Letter from applicant's architect, dated April 15, 1998 (three pages) 9. Findings for Variance prepared by Mr. Grange (two pages) 10. Findings for Conditional Development Permit prepared by Mr. Grange (one page) 11. Tree Survey prepared by Herb Fong dated March 19, 1998 (one page) 12. Light fixture specifications (one page) 13. Worksheet#2 14. Development plans: site, floor and roof plans, elevations and sections (five sheets) cc: Lily Huang Randy Grange 318 S. GordonWay 21 Dwight Road Los Altos, CA 94022 Burlingame, CA 94010 Planning Commission Lands of Huang April 22, 1998 Page 9 ATTACHMENT 1 RECOMMENDED CONDITIONS FOR SITE DEVELOPMENT PERMIT, CONDITIONAL DEVELOPMENT PERMIT AND VARIANCE FOR NEW RESIDENCE LANDS OF HUANG, 27760 SHERLOCK ROAD A. PLANNING DEPARTMENT: 1. Any changes or modifications to the approved plans shall be approved by the Planning Director or the Planning Commission, depending upon the scope of the changes. 2. Subsequent to final framing, a landscape screening and erosion control plan shall be reviewed at a Site Development Hearing. Particular attention shall be given to plantings which will be adequate to break up the view of the new residence from surrounding properties and streets. At least 3 native oak trees are required to be planted with the landscape screening to replace the heritage oaks proposed to be removed for the construction. The oaks should be located to help mitigate for the visual impact of the deck. Special attention shall be given to planting which will mitigate the view of the deck from below. All landscaping required for screening purposes or for erosion control (as determined by the City Engineer) must be installed prior to final inspection, unless the Planning Director fmds that unusual circumstances, such as weather or site conditions, require that planting be delayed. In those instances, a deposit of an amount equal to the cost of landscape materials and installation, to the satisfaction of the Planning Director, shall be submitted to the Town. Landscaping shall in any event be installed not later than six months after final inspection, or the deposit will be forfeited. 3. A landscape maintenance deposit (or certificate of deposit), equal to the cost of materials and installation for all landscaping required for screening purposes or for erosion control (as determined by the City Engineer), but not to exceed $5,000, shall be posted prior to final inspection. An inspection of the landscape to ensure adequate establishment and maintenance shall be made two years after installation. The deposit will be released at that time if the plantings remain viable. 4. Prior to beginning any grading or construction operations, all significant trees in the vicinity of construction shall be fenced at the dripline. The fencing shall be of material and structure to clearly delineate the dripline. Planning Commission Lands of Huang April 22, 1998 Page 10 Town staff must inspect the fencing and the trees to be fenced prior to commencement of grading or construction. The fencing must remain in place throughout the course of construction. No storage of equipment, vehicles or debris shall be allowed within the driplines of these trees. Any grading or work to be done within the dripline of a heritage oak must be supervised by a certified arborist and a report shall be submitted prior to final indicating the health of the heritage oaks and that any repair work on the trees has been completed. 5. Paint colors shall be chosen by the applicant and approved by staff in conformance with the Town's adopted color board, and shall exhibit a light reflectivity value of 50 or less. Roofs shall use materials which have a light reflectivity value of 40 or less. White trim area should be minimized, particularly on large surfaces such as doors, columns, railings, and trellises. A color sample shall be submitted to the Planning Department for approval prior to acceptance of plans for building plan check. All applicable structures shall be painted in conformance with the approved color(s)prior to final inspection. 6. Skylights shall be designed and constructed to reduce emitted light. No lighting may be placed within skylight wells. 7. Fire retardant roofing is required for the new construction. 8. Locations and specifications for outdoor lighting shall be submitted for Planning Department approval prior to acceptance of plans for building plan check. Any additional outdoor lighting shall be reviewed with the landscape plan. Lighting fixtures shall generally be downlights. Exceptions may be permitted in limited locations (entry, garage, etc.) or where the fixtures would not be visible from off site. Any security lighting shall be limited in number and directed away from clear view of neighbors, and shielding with shrouds or louvers is suggested. Lighting shall be low wattage, shall not encroach or reflect on adjacent properties, and the source or lighting should not be directly visible from off site. No lighting may be placed within the setbacks except for 2 driveway or entry lights, except where determined to be necessary for safety. 9. As recommended by Cotton, Shires & Associates in their report dated April 14, 1998, the applicant shall comply with the following: a. The applicant's geotechnical consultant shall review and approve all geotechnical aspects of the development plans (i.e. site preparation and grading, site drainage improvements and design Planning Commission • Lands of Huang April22, 1998 Page 11 parameters for foundations and driveway) to ensure that his recommendations have been properly incorporated. The results of the plan review should be summarized by the geotechnical consultant in a letter and submitted to the Town Engineer for review and approval prior to acceptance of plans for building plan check. c. The geotechnical consultant shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections should include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations prior to placement of steel and concrete. The consultant shall verify that any new fill materials are properly keyed and benched into competent earth materials. The results of these inspections and the as-built conditions of the project shall be described by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to final (as built)project approval. For further details on the above requirements, please refer to the letter from Cotton, Shires &Associates dated April 14, 1998. B. ENGINEERING DEPARTMENT: 10. Any, and all, changes to the approved grading and drainage plan shall be submitted as revisions from the project engineer and shall first be approved by the Town Engineering Department. No grading shall take place during the grading moratorium between November 1 and April 1 except with prior approval from the City Engineer. No grading shall take place within ten feet of any property line except to allow for the construction of the driveway access or where a variance has been approved. 11. All public utility services serving this property shall be placed underground. 12. Two copies of a grading and construction operation plan shall be submitted by the property owner for review and approval by the City Engineer and Planning Director prior to acceptance of plans for building plan check The grading/construction plan shall address truck traffic issues regarding dust, noise, and vehicular and pedestrian traffic safety on Planning Commission Lands of Huang April 22, 1998 Page 12 Moody Road and surrounding roadways; storage of construction materials; placement of sanitary facilities; parking for construction vehicles; and parking for construction personnel. A debris box (trash dumpster) shall be placed on site for collection of construction debris. Arrangements must be made with the Los Altos Garbage Company for the debris box, since they have a franchise with the Town and no other hauler is allowed within the Town limits. 13. The property owner shall inform the Town of any damage and shall repair any damage caused by the construction of the project to pathways, private driveways, and public and private roadways,prior to final inspection and shall provide the Town with photographs of the existing conditions of the roadways and pathways prior to acceptance of plans for building plan check 14. The driveway shall be required to be fully constructed, to the satisfaction of the City Engineer,prior to final inspection. 15. The property owner shall dedicate an additional 10' to equal a total 30 foot wide half-width public right of way to the Town along Moody Road. Any additional right of way which has already been dedicated to the public can be vacated at the same time that the new right of way dedication is made. The property owner shall provide legal description and plat exhibits for both the dedication and the vacation prepared by a licensed land surveyor and the Town shall prepare the dedication and vacation documents. The dedication document, including approved exhibits, shall be signed and notarized by the property owner and returned to the Town prior to acceptance of plans for building plan check 16. The property owner shall make an irrevocable dedication to the public for right of way over the existing Sherlock Road 20' wide private road easement. The property owner shall provide legal description and plat exhibits for the dedication prepared by a licensed land surveyor and the Town shall prepare the dedication document. The dedication document, including approved exhibits, shall be signed and notarized by the property owner and returned to the Town prior to acceptance of plans for building plan check 17. A permit for the septic system shall be issued by Santa Clara County Health Department prior to acceptance of plans for building plan check 18. Conditions of Santa Clara County Health Department shall be met prior to final inspection. Planning Commission • Lands of Huang April 22, 1998 Page 13 19. The site drainage associated with the proposed development must be designed as surface flow wherever possible to avoid concentration of the runoff. The proposed drainage shall be designed to maintain the existing flow patterns. A final grading and drainage plan shall be submitted for approval by the Engineering Department prior to acceptance of plans for building plan check. Final drainage and grading shall be inspected by the Engineering Department and any deficiencies corrected to the satisfaction of the Engineering Department prior to final inspection. A letter shall be submitted from the project engineer stating that the drainage improvements were installed as shown on the approved plans and in accordance with their recommendations prior to final inspection. 20. The property owner shall grant a conservation easement to the Town over all undeveloped portions of the property where the slope is 30% or greater. A provision shall be made in the conservation easement agreement which shall allow for the construction and maintenance of the approved septic system for the property. The property owner shall provide legal description and plat exhibits that are prepared by a licensed land surveyor and the Town shall prepare the grant document. The grant document, including the approved exhibits, shall be signed and notarized by the property owner and returned to the Town prior toacceptance of plans for building plan check. 21. The applicant shall dedicate a pathways easement to the Town over the 20 foot wide Sherlock Road right of way. The property owner shall provide legal description and plat exhibits for the dedication prepared by a licensed land surveyor and the Town shall prepare the dedication document. The dedication document, including approved exhibits, shall be signed and notarized by the property owner and returned to the Town prior to acceptance of plans for building plan check C. FIRE DEPARTMENT 22. The driveway shall be a minimum of 14 feet wide, shall have a vertical clearance of 13 feet six inches, shall be designed and maintained to support the imposed loads of fire apparatus (40,000 pounds) and shall have an all weather surface. 23. The property address shall be placed on the property so that it is clearly visible and legible from Sherlock Road. The address numbers shall be a minimum of four inches high and shall contrast with the background color. 24. Prior to fmal inspection, the applicant shall install a fire sprinidering system and/or install fire hydrants to assure that adequate flow is available Planning Commission Lands of Huang April 22, 1998 Page 14 to the residence. The design and type of fire protection shall be reviewed and approved by the fire department prior to acceptance of plans for building plan check. 25. The required driveway installations shall be in place, inspected, and accepted by the Fire Department prior to the start of construction. Bulk combustible construction materials may not be delivered to the construction site until installations are completed as stated above. Upon completion of the construction, a final inspection shall be required to be set with the Planning and Engineering Departments two weeks prior to final building inspection approval. CONDITION NUMBERS 5, 8, 9, 12, 13, 15, 16, 17, 19, 20, 21 AND 24 SHALL BE COMPLETED AND SIGNED OFF BY THE PLANNING DIRECTOR AND THE CITY ENGINEER PRIOR TO ACCEPTANCE OF CONSTRUCTION PLANS FOR PLAN CHECK BY THE BUILDING DEPARTMENT. Properties residing within the Los Altos School District boundaries must pay School District fees before receiving their building permit from Los Altos Hills. The applicant must take a copy of Worksheet #2 to both the elementary and high school district offices, pay the appropriate fees and provide the Town with a copy of their receipts. NOTE: The Site Development permit is valid for one year from the approval date (until April 22, 1999). All required building permits must be obtained within that year and work on items not requiring a building permit shall be commenced within one year and completed within two years. Planning Commission Lands of Huang April22, 1998 Page 15 ATTACHMENT 2 RECOMMENDED FINDINGS FOR APPROVAL OF VARIANCE TO ALLOW DEVELOPMENT AREA TO EXCEED MAXIMUM FLOOR AND DEVELOPMENT AREA, TO ALLOW STRUCTURES AND PARKING WITHIN THE SETBACK, AND TO ALLOW FOR SUBSTANDARD SIZE PARKING SPACES LANDS OF HUANG-27760 SHERLOCK ROAD • 1. Because of exceptional and extraordinary circumstances applicable to the subject property, including size, shape, topography, location or surroundings, the strict application of the provisions of this Title is found to deprive such property of privileges enjoyed by other properties in the vicinity and under identical zoning classification; The lot is encumbered with numerous access easements and when combined with the shape of the lot, leave very little area to develop outside of the setbacks. The additions are located in the most level portion of the lot and encroach into the setbacks. The proposed additions to the residence are minimal in height and square footage and follow the slope with the finished floor and the roofline. The increased distance of the development from Sherlock Road would allow for screening and therefore the additions would not be intrusive to neighbors. The proposed parking spaces are located on the level portion of the lot and 2 of the spaces would be standard 10 foot by 20 foot spaces. The available parking on site would be improved from the existing configuration. The proposed additions would exceed the MFA and the MDA of the property. The size of the property before the deduction of the private access easement and the Moody Road right of way is over 1 acre. Due to the large area of the lot which is deducted for access easements, the MDA and MFA is relatively small. The size of the addition and development area is close to the maximums allowable on the lot and is designed to fit into the site and would be well under the 5,000/4,000 minimums allowed for lots with a L.U.F. greater than 0.50. 2. Upon the granting of the variance, the intent and purpose of the applicable sections of the Zoning Ordinance will still be served and the recipient of the variance will not be granted special privileges not enjoyed by other surrounding property owners. The proposed development for the site would not be out of character for the homes in the neighborhood or within the Town. The addition to the residence is minimal in height and square footage and fits into the slope of the lot and the outdoor living area is minimal in size. The granting of the variances for the parking areas would Planning Commission Lands of Huang April 22, 1998 Page 16 allow for 4 parking spaces on site, as required by the code and a more conforming situation than the existing configuration. 3. The granting of such variance will not be materially detrimental to the public welfare or injurious to the property, improvements or uses within the immediate vicinity and within the same zoning district. The granting of the variance for the additional floor and development area would not negatively impact any neighboring properties, as the additions would have a negligible impact visually. No significant grading will be required and the development would not be located close to the neighboring properties. The granting of the variances for the encroachment into the setbacks would not impact any immediate neighbors, as the setbacks are adjacent to Moody Road and Sherlock Road. The granting of the variance for the substandard dimensions for the parking spaces would benefit neighbors by allowing for more parking on the property. 4. The variance will not authorize a use or activity which is not otherwise expressly authorized by the Zoning District regulations governing the parcel of property. The proposed floor and development area would be used for an addition of living area, a garage, driveway and outdoor living area which are uses that are consistent with the residential zoning designation of the property and surrounding properties. Planning Commission Lands of Huang April 22, 1998 Page 17 ATTACHMENT 3 • LANDS OF HUANG- 27760 SHERLOCK ROAD CONDITIONAL DEVELOPMENT PERMIT FINDINGS 1. The site for the proposed development is adequate in size, shape, and topography to accommodate the proposed intensity of development, including all structures, yards, open spaces,parking, landscaping, walls and fences, and such other features as may be required by this chapter. The size of the lot before the dedications is 1.08 acres and although it will be reduced to .612 with the additional dedication of right of way, the perceived lot size will not change. The intensity of the proposed development and floor area is appropriate for the lot size and the development has been sited in the flattest area of the lot. 2. The size and design of the proposed structures create a proper balance, unity and harmonious appearance in relation to the surrounding neighborhood. The proposed additions to the residence would step with the contours of the lot and the roofline slopes with the natural slope of the lot. The relocation of the garage would reduce the amount of development located within the setback and would increase the distance of the development from Sherlock Road, improving the relationship of the development to the surrounding neighborhood. 3. The rural character of the site has been preserved as much as feasible by minimizing vegetation and tree removal, excessive and unsightly grading and alteration of natural land forms. The construction of the additions and parking area would minimally increase the amount of development existing on the lot. Minimal grading would be required as the additions are proposed at the most level part of the lot and generally meets the Town's grading policy. Relocating the garage further from Sherlock Road will allow for some planting and screening of the development. 4. The proposed development is in compliance with all regulations and policies set forth in the Site Development ordinance. The proposed additions and parking areas would require variances to encroach into the setbacks, exceed the maximum floor and development area and to have substandard parking areas, however, the existing development on the site encroaches into the setbacks and does not have adequate parking and the proposed development would improve the site conditions. 04/07/98 10:58 122408 378 9342 CFPD 2002 ATTACHMENT 4 ' , ' A %, FIRE DEPARTMENT� lt 9. 411 Li!ic A SANTA CLARA COUNTY. CONTROL NUMBER if E5.1997• 14700 Winchester Blvd.,Los Gatos, CA 95030-1818 BLDG PERMIT NUMBER GOURR:9Y 5 SERVICE (408)378-4010(phone)•(408)378-9342(fax) p PLAN REVIEW NUMBER 98-0470 RLENUMBER 250-97-ZP-S DEVELOPMENT REVIEW COMMENTS CODE/SEC. SHEET NO. REQUIREMENT Review of site plan for proposed remodel of an existing single family residence. Scope of work involves the addition of 498 square feet to an existing 946 square foot house and attached garage. The planner for this project is Ms. Susan Manca. 1 Review of this Developmental proposal is limited to acceptability of site access and water supply as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determinecompliance with adopted model codes. Prior to performing any work the applicant shall apply to the Building Department for applicable construction permits. uFc 2 Required Fire How: Required fire flow for this project is 1000 GPM at 20 psi Appendix11[- residual pressure. The required fire flow is not (*) available from area water mains and fire hydrant(s) which are spaced at the required spacing. * Note: existing fire main does not appear to be within the appropriate spacing • requirement. UFC 3. Required Fire Flow Option (Single Family Dwellings): Provide required fire 903.2 flow from fire hydrants spaced at a maximum of 500 feet (*), OR Provide an approved fire sprinkler system throughout all portions of the building. The fire sprinkler system shall conform to National Fire Protection Association Standard #13D, 1994 Edition, and local ordinance requirements. (*) As mentioned in item#3 above, 500 feet spacing refers to any project being located no further than 250 feet from an approved hydrant. In this case, the project site appears to be in excess of 250 feet from said hydrant. DISTRICT PLANS SPECS NEW FWDL AS OCCUPANCY CONST.TYPE PERMITTEE DATE PAGE LAH ❑ ❑ 0 0 0 GIULIANI &KULL INC 03/11/98 1 OF 2 SECJFLOOR AREA LOAD DESCRIPTION BY Residential Development Hokanson,Wayne NAME OF PROJECT LOCATION SFR-HUANG 27760 Sherlock Rd A California Fire Protection District serving Santa Clara County and the communities of Campbell,Cupertino,Los Altos,•Los Altos Hills,Los Gatos,Monte Sereno,Morgan Hill,and Saratoga 04/07/98 10:59 2408 378 9342 CFPD 4003 6 °6 FIRE DEPARTMENT Irmo Di' SANTA CLARA COUNTY. CONTROL NUMBER ES7 1947• 14700 Winchester Blvd.,Los Gatos, CA 95030-1818 BLDG PERMIT NUMBER GOER.6555VICe (408)378-4010(phone)• (408)378-9342(fax) 98-0470 PLAN REVIEW NUMBER ��++ FlLENUMBER 250-97-ZP-S DEVELOPMENT REVIEW COMMENTS CODE/SEC. SHEET NO. REQUIREMENT Lipo 4. Premises Identification: Approved numbers or addresses shall be placed on all 901.44 new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Numbers shall contrast with their background and be a minimum of four inches in height. 'DISTRICT PLANS SPECS NEW RMDL AS OCCUPANCY CONST.TYPE PERMITTEE DATE PAGE LAH 0 0 ❑ 0 0 GIULIANI&KULL INC 03/11/98 2 of 2 SECJFLOOR AREA LOAD DESCRIPTION BY Residential Development Hokanson,Wayne NAME OF PROJECT LOCATION SFR-HUANG 27760 Sherlock Rd A California Fire Protection District serving Santa Clara County and the communities of Campbell,Cupertino,Los Altos,Los Altos Hills,Los Gatos,Monte Sereno,Morgan Hill,and Saratoga • AITACHMENT5 RECEIVED re, COTTON, SHIRES & ASSOCIATES, INC. APR 1 5 1998 CONSULTING ENGINEERS AND GEOLOGISTS TOWN OF LOS ALTOS HILLS April 14, 1998 L3098A TO: Susan Stevenson Planner TOWN OF LOS ALTOS HILLS_ 28379 Fremont Road Los Altos Hills, California 94022 SUBJECT: Supplemental Geotechnical Review RE: Huang Additions 27760 Sherlock Road #250-97-ZP-SD-GD At your request, we have completed a supplemental geotechnical review of proposed site improvements using: • Portion of Septic Leachfield Design Analysis (report) prepared by Questa Engineering Corporation, dated August 20, 1997; • Site Development Plan (1 sheet, 20-scale) prepared by Giuliani & Kull, dated October 15, 1996; and • Septic Disposal Plans (2 sheets) prepared by Questa Engineering Corporation, dated August 20, 1997. In addition,we have reviewed pertinent technical documents from our office files and have been in.communication with various project consultants. DISCUSSION The applicant proposes to expand an existing residence (total new floor space not to exceed 500 square feet), improve an existing driveway, add a deck and upgrade/expand a septic leachfield system. In our previous review report(dated March 27, 1998) we recommended that specific evaluations concerning the proposed septic leachfield system be addressed prior to geotechnical approval of the site development plan. CONCLUSIONS AND RECOMMENDED ACTION The referenced report prepared by Questa Engineering Corporation addresses the percolation characteristics of site soils and presents the results of their analysis that the proposed leachfield should not create slope instability problems. Consequently, the issues of our previous review have been addressed and we recommend geotechnical approval of the proposed site development plan with the following conditions: Northern California Office Southern California Office 330 Village Lane 5245 Avenida Encinas •Suite A Los Gatos,CA 95030-7218 Carlsbad,CA 92008-4374 (408)354-5542 •Fax(408)354-1852 (760)931-2700 • Fax(760)931-1020 e-mail:losg@csageo.com e-mail:carl@csageo.com Ms. Susan Stevenson April 14, 1998 Page 2 L3098A 1. Geotechnical Plan Review - The applicant's geotechnical consultant shall review and approve all geotechnical aspects of the development plans (i.e., site preparation and grading, site drainage improvements and design parameters for foundations and driveway) to ensure that his recommendations have been properly incorporated. The results of the plan review should be summarized by the geotechnical consultant in a letter and submitted to the Town Engineer for review and approval prior to issuance of building permits. 2. Geotechnical Field Inspection-The geotechnical consultant shall • inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections should include,but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations prior to the placement of steel and concrete. The consultant shall verify that any new fill materials are properly keyed and benched into competent earth materials. The results of these inspections and the as-built conditions of the project shall be described by the geotechnical consultant in a letter and submitted to the City Engineer for review prior to final (as- built) project approval. This review has been performed to provide technical advice to assist the Town with discretionary permit decisions. Our services have been limited to review of the documents previously identified, and a visual review of the property. Our opinions and conclusions are made in accordance with generally accepted principles and practices of the geotechnical profession. This warranty is in lieu of all other warranties, either • expressed or implied. Respectfully submitted, COTTON, SHIRES AND ASSOCIATES,INC. TOWN GEOTECHNICAL CONSULTANT Ted Sayre Senior Engineering Geologist CEG 1795 Patrick O. Shires Principal Geotechnical Engineer GE 770 POS:TS:ad COTTON, SHIRES& ASSOCIATES, INC. 3\ 3 / --2,/7 7-4 , Q „,7 ., J Los Altos HillRSCSVSIST° Town of A�� 3/31/98 • �p A To: Planning Commission & Staff path on the West side o►" 4119/ 101* • �;� from that point constr ive path From: Les Earnest,Pathways at the toe of the slope along Stonebrook Committee Chair connecting to the existing native path Subject 1998 Pathway leading to Juan Prado Mesa Preserve. 1/26/98 recommendations 14470 Manuella; Lands of Kwong: This is a cumulative listing of all Construct II-B path along Manuella. pathway recommendations for 1998, in 3/23/98 alphabetical order by street and number, with the effective date at the end of 12580 Miraloma Way; Lands of Harari: each item. In cases where a No request 1/26/98 recommendation for a given address has 11471 Page Mill Road; Lands of Wilson: been revised, two dates are shown but Provide sufficient easement along Page only the final recommendation is listed. Mill Road to encompass at least 10 feet Where construction or upgrading of from the top of the bank and construct a paths to the II-B standard is native path along this route; construct recommended, it is to include irrigation an off-road native path on the South at least 5 feet away from path and a side of Buena Vista Drive beginning non-slip surface on any crossing about 50 feet from Page Mill Road and driveways. Where there is "no request" ending adjacent to Buena Vista at the the Committee recommends that in lieu East boundary of the property and fees be collected where possible. provide a pathway easement at least 10 Recommendations feet wide that encompasses this route. 1/26/98 12025 Adobe Creek Lodge Road; Lands of 11972 Rhus Ridge Road; Lands of Malek Chang: Construct II-B path along Adobe No request 1/26/98 Creek Lodge Road separated from the road by 5 feet Construct II-B path in a 13474 Robleda Road;Lands of Danver: 20 foot easement adjacent to Moody No request 3/23/98 Road at the toe of the slope. 1/26/98 24055 Jabil Lane; Lands of Yeh: In order 12238 Via Arline; Lands of Robinson& to connect to a future path to Fernhill, Ikeda No request. 1/26/98 construct a II-B path along Jabil Lane 12246 Via Arline; Lands of Godby: No from Magdalena to the Southeast corner of the property. 3/23/98 request. 3/23/98 27760 Sherlock Road; Lands of Huang: 14470 De Bell Road; Lands of Wong: No Provide a pathway easement on Sherlock. request 1/26/98 3/23/98 12010 Elsie Way;Lands of Murthy& Srinath: Restore II-B path along Concepcion Road. 3/23/98 25935 Estacada Way; Lands of Lee: No request. 2/23/98 25518 Hidden Springs Lane;Lands of Bower: Restore II-B path along Altamont; reconstruct II-B path'along eastern boundary. 2/23/98 • . 24004 Oak Knoll Circle;Lands of Gorman: Restore II-B path along Oak Knoll Circle; construct a II-B path along Stonebrook from Oak Knoll Circle to a point opposite the beginning of the II-B ATTACHMENT ENVIRONMENTAL DESIGN COMMITTEE RECEIVED LANDSCAPE/HARDSCAPE EVALUATION MAR 0 9 1998 Applicant's Name: TOWN oF�osa�ro s K►Lcs Address: o? '7 4, Reviewed by: KL"f—Lc4 s ��L Y?C.Date: - — e Mitigation needed: Visibility from off site: from distance (directions), from nearby neighbors (directions) (include need for screening for privacy). Noise: from pump/pool , air conditioner , sport court Light: from fixtures , automobile headlights" Fence materials: color , open/solid . Erosion control Other: Planting Plan Evaluation: (Circle required trees and shrubs on plan) Are species appropriate: Deciduous? Future height(view, solar, drive/path blockage) Fire hazard Hardiness/frost Drought tolerance Meet mitigation needs Creeks and drainage: Is there a conservation easement? Are there sufficient protections in place. Will fences impact wildlife migration? Invasive species should not be planted near a waterway. Other: Are there obstructions to pathways, including future growth of plants? Are all noise mitigations in place? No construction in road right-of-way. Ir. '� � dte-- X t/V t 7f its '� U✓ - ATTACHMENT J' TRG Ar itecpts APP 1 5 1998 April 15, 1998 TOWN OF LOS ALTOS HILLS Town of Los Altos Hills Planning Commission 26379 Fremont Rd. Los Altos Hills, CA Dear Commission members, You are being asked to review an addition to the house at 27760 Sherlock road. This letter will attempt to explain the complications associated with the site that force us to apply for several variances. The legal house and lot pre-date the Town of Los Altos Hills and it is impossible to meet the new standards imposed by the Town. Road cuts, access easements enjoyed by most of the neighboring properties at the expense of this property (wholly on the site rather than on shared property lines), and other factors beyond the property owner's control, clearly deprive the property of privileges enjoyed by others in the vicinity. The existing house and garage structure is an eyesore that has irritated the neighbors for years. Our proposal will completely clean up the site. The goal is not to over-build the site. This proposal represents the minimum development necessary to make the place livable. We believe that our proposal is reasonable and that this site presents the exact type of situation in which the required variances should be approved Septic: Regardless of whether or not an addition to the residence is constructed, a new septic system is needed. The site does not allow for the current standard leach field (400 feet active &400 feet expansion). A specialty engineer has designed a fully functioning system for the house that has been approved for construction by the county. The proposed leach field is best if held back as far from the Moody Rd. cut as possible. Doing this puts the uppermost leach line less than 10 feet from the Sherlock Rd. easement. The Town requires leach lines to be a minimum of 10 feet from an easement, but the county has no such requirement. We feel that it would be best to keep the leach field as shown on the proposal. Floor Area: Depending upon how one calculates the LUF for the site, one could come up with a variety of allowable floor.areas (see LUF discussion below). The fact that the proposed septic system does not meet typical requirements means that the County Health Department will allow a maximum expansion of the conditioned floor area of 500 SF. ( they have already approved this addition). We are proposing just less than that which results in a pretty small house. In addition, we are proposing a two car garage. It seems that the garage would be desirable even though we would be well below the 21 Dwight Road • Burlingame, CA 94010 • (650) 579-5762 Town's allowable floor area without it. If approved, the Town will have the opportunity to get the existing garage structure (completely inside the setback lines) removed. Development Area: The maximum development area numbers are extremely difficult to meet. The proposed deck is about as small as it can possibly be and still be usable. Without it, there is nowhere to go outside the house. We need to have a paved driveway and parking stalls. The maximum development area might be met by front loading the garage, and having additional parking to its side. We felt that this solution would be less attractive with the garage doors and outside cars more visible. It would also require additional grading and retaining walls. Setback Encroachments: The proposed garage encroaches into the setback, but we think this will be an improvement over the current situation as we are proposing to remove the existing garage structure. The proposed additions to the house, the existing house, and the proposed additional parking spaces encroach into the new setback lines created by the new dedications along Moody Rd. Originally, we believed the addition to be a "minor addition" because the net increase in floor area was far less than 900 SF. That would mean that additional dedications along Moody Rd. would not be required. If you look at the existing setbacks, our proposal complies. It was later determined that we would be required to make additional dedications along Moody Rd. because the area of new construction was greater than 900 SF. This moves the setback lines in to a new location that is impossible to meet. Had we proposed a one car garage, the area of new construction would be less than 900 SF., the dedications would not be required, and we would meet the setbacks. We considered this option but feel that it is better for everyone to have two enclosed parking spaces rather than conform to an imaginary line. LUF: The LUF that one calculates for this site can vary dramatically depending on how it is calculated. On the final submission, we show a conservative set of numbers and another set with an asterisk beside it. In addition to the Moody and Sherlock Rd. easements, there is also a personal access easement between this property and the neighbors. The neighbor uses a portion of it for their driveway, but the rest remains and will remain unused. The numbers with the asterisk beside them represent what the calculations would be if the unused portion of the access easement is abandoned in the future. Both sets of numbers include making the additional dedications along Moody Rd. Other properties along Sherlock Rd. have made additional dedications on Sherlock, but it was determined by the Planning Staff and Town Attorney that those dedications would not be required (it would mean that the leach field would be in the easement and would leave us with almost no buildable area). While this letter only scratches the surface of the "if this then that" issues on this property, we hope that it helps you to understand the complexities of the site. It has been nearly a two year process to get to this point and we are excited by the prospect of finally having the project reviewed. We believe that the proposal is logical and minimal. The neighbors will all be happy when they no longer have to drive by the mess that is up there now. We look forward to the hearing. Sincerely, andy Grange Architect ATTACHMENT q TRG Associates Architecture and Planning RECEIVED April 6, 1998 APR - 7 1998 FINDINGS FOR VARIANCE STATEMENT (parking) TOWN OF LOS ALTOS HILLS 27760 Sherlock Rd. Los Altos Hills 1. This proposal shows two parking spaces within the setback lines. Extraordinary circumstances on the property make this necessary. First, we are not altering the existing situation. Parking already occurs in the same area of the site, and our proposal will "clean it up" . Second,there is nowhere else to put these two spaces (required by the Town) and not have them in the setback. Other locations would be more visible and also require retaining walls and large quantities of fill. 2. The intent of the ordinance will be served. The recipient of this variance will not be granted special privileges. We will be meeting the Town of Los Altos Hills'parking requirements. 3. The proposal will not be detrimental or injurious to the surrounding properties. 4. No unauthorized use or activity is being proposed. '21 Dwight Road • Burlingame, CA 94010 • (650) 579-5762 February 19, 1998 FINDINGS FOR VARIANCE STATEMENT 27760 Sherlock Rd. Los Altos Hills 1. This property qualifies as one which-has exceptional-conditions. This-legal lot and house pre-date the Town of Los Altos Hills. Since its-eonstruetion-,many things-around it - have changed which make it impossible to meet all all=uiew ordinances, Moody-Road has been re-graded, Sherlock road has been installed and its-easement sits almost completely whithin-this property rather than'wining along:shared-property lines,them. areprivate access-easements on the site-enjoyed by neighboring properties-at the_expense of this property. These easements have an excessive impact en net area. 2. The intent of the ordinance will be served. We are proposing the least amount of development possible which will result in a reasonable-residence(far less than- surrounding properties). The proposed stmt.-lute is as-low;; as far set back, andassmall as practicable. The proposal will remove an existing structure that is-incomplete violation of the ordinance and will vastly improve the-visual impact-of the site. 3. The proposal will not be detrimental or injurious-to-the surrounding properties Health and safety will be improved. 4. No unauthorized use or activity is being proposed. ; ATTACHMENT ID February 19, 1998 FINDINGS FOR CONDITION,DEVELOPMENT PERMIT 27760 Sherlock Rd. Los Altos Hilrs 1. The proposed intensity of development is as minimal-as-practicable. We beh eve that the 1+ acre site is adequate in size shape and topography to acc-ommodate this development. 2. The size and design ofthe development creates the lowest, smallest structure possible and greatly improves its visual impact on the-neighborhood. 3. The rural character of the site has been.preserved.as-much as feasible. There is almost no grading required to achieve the proposed design We will be happy to • incorporate the planting of new trees and landscaping-iutu-the final drawings, ieplaciug any trees removed for construction. 4. The proposed development is in compliance with the Site Development Ordinance. Lighting at the garage door can be masked by tree planting ATTACHMENT j� Herb Fong Certified Arborist - Western Chapter ISA Lic. #148 315 Bonair Siding Stanford, Calif. 94305 - 415-725-3175 • • 3/19/98 • Ms. Lily Huang 318 S. Gordon Way Los Altos, Calif. 94022 Re: Tree at 27760 Sherlock Rd., Los Altos Hills Dear Ms. Huang, At the request of your architect, I visited the site on Sherlock Rd to examine the oak tree in question. This tree is an approximately 10-12 inch diameter Live Oak, Quercus agrifolia. The tree has been poorly pruned in the past resulting in numerous suckers growing along the trunk. The tree is immediately next to the home or structure with less than 6inches of clearance. Tree is growing on a slope and some of the primary roots are exposed. The trunk appears sound and free of disease but the form and habit of the tree are not good because of past unskilled care. Because of the proximity of the home and current condition of the tree T would not recommend the extra cost and burden of saving this tree. A boxed specimen tree could be better situated on the property to replace this tree if removed. If you must save this tree a conventional foundation is not appropriate and a post and beam type foundation should be considered with the posts situated to avoid any primary roots. The clearance of the tree is such that roof lines may need to be altered to accommodate this tree. If you should wish to pursue the saving of this tree I can give you more detailed specifications for your builder. In summary,.I would not consider the saving of this tree because of its proximity to the structure and the poor condition of the tree. If you have any further questions, please do not hesitate to call me. Sincerely, 2/2'd SN011ha3dO S3I!I1IJhd Wdt70:S0 86, •E t &JW 1W .Mini CylinderOutdoor Downlight • 9.25"hx5:75"wx4:25"p.4.75"MC M.--„ .> Incan ' Single Porcelain Socket / .ATTACH `- I OOV1/Type A-19 Lamp Max. r • ti d, Af 7 V T't Fluor- (I)PL Socket. : • • • 13WPL-C.Quad.Lamp • ''' r W _ ',Halgn- NotSuitable for Halo en • -. Halogen <4 s ' - 945W. Mini.Cylinder-Outdoor(Open) --.-COP4::':).17-.....- a � • , 925".hx5.75"wx425"p, 4:75"MC :� 995W ,�ti;} a `,tf`` fig_;. • Incan- , Sheltered Porcelain Socket. • = if' ;,-'x 60WTypeA-19 Lamp Max - • : > ,s'. - . •` Fluor- ,Sheltered FL Socket- `; ` I3W PL-C Quad Lamp ' ' . Halgn Not Suitable forHalogem s • , „..,......„:„.„„...,..„,...„.4.' . ..4,..,...„. .„.,.....„, . 995W Mini Cylinder Pelf-Outdoor(Open) :it • ; .` 9.25”h x 5.75"w 4.25"p, 4.75"MC • y; x .--x Incan- Sheltered Porcelain Socket . - u; " 60WType A-19 Lamp Max *r,} "`-'� Fluor - Sheltered PL Socket :Y ' F , r - 1295W 13W PLC Quad Lamp tis'` a a s:, Halgn- Not Suitable forHalogen +• ' 1260W Cylinder Outdoor Downlight 12.5 hx75"wx65"p, 6.25".MC ' Incan- Not Suitable for Incandescent. ` ; :Fluor- (I)PL.Socket c ,-. ' /1•3W PL-STwin Lamp Holgn'- Not Suitable for Halogen _ • 1265W Cylinder-Outdoor(Open) . ` 1650W,'•••- • 125"h x 75"w x 65"p. 5"MC s . Incan- Sheltered Porcelain Socket 60WTypeA 19 Lamp Max Fluor- Sheltered PL Socket p °; ' I3W PL-C Quad Lamp a ; .Holgn- Not Suitable for Halogen '" �;, 1295W• Cylinder Perf-Outdoor(Open) . 125"'hx75"wx65"p, 5"'MC �' ~" `` """ Main-• Sheltered Porcelain Socket •• • .i 60WType A-I9 Lamp Max Fluor- - Sheltered PL Socket • , ' ' • 13W PL-C Quad Lamp -i'- .` • • Halgn- Not Suitable for Halogen _r 1300W • Mini Quarter Sphere-Outdoor Downlight • „ • - •- 4.25"hx 10.25"wx5"p, 2"MC •• V Incan- Single Porcelain Socket `''"3 100WT e A-19 LampMax ; r f c y YP Fluor- (I)PL Socket i f _ 13W PL-CQuadLarnp ;5 �'• r Halgn- Not Suitable•for Halog •en `� • 1355W= Quarter Sphere-Outdoor Downlight 1 }_. . 6"h x 135"w x 6.75"p, 2.75"'MC •.•:.•,•-•.,•,_!.• Incan- Single Porcelain Socket 100WType A-I9 Lamp Max w • • Fluor - (I)or(2)PL Sockets(specify) (2) 13W PL-STwin Lamps _ K �„ Halgn- Not Suitable for Halogen 1650W Shell-Outdoorpownlight 1+ t=` • '} 7'h x 165"w x 7.25"p, 3"MC . -_ '` • �: Incan- Double Porcelain Socket. k{;, x „' (2)60WTypeA-I9 Lamps Max � 4 • ".�,., 'r` Fluor- (I)or(2)PL Sockets(specify) } 1265W (2) 13W PL-STwin Lamps • • •=•-•-.-2,-,74.:::••••.` • _ • ` Halgn- Not Suitable for Halogen • �r •. x,_ n W, ` } i40E,1,. .r• ,,,i„ ,f 945W ., s 44�ctt ia .. _ter 3, .e •„-tin,'. =s-V . • ,f . C) . See finishes on pp 27-29 •• , Complete ordering guidelines on p.30 - ' , • • • ATTACHMENT j 3 TOWN OF LOS ALTOS HILLS PLANNING DEPARTMENT 26379 Fremont Road•Los Altos Hills, California 94022 • (415)941-7222 • FAX(415)941-3160 WORKSHEET #2 EXISTING AND PROPOSED DEVELOPMENT AREA AND FLOOR AREA • TURN IN WITH YOUR APPLICATION • PROPERTY OWNER'S NAME Cr NUA NG- PROPER1'Y ADDRESS 2.7-7 6 0 S 1+E 12L o c,K 2b . Los Pre-.-1r.:s I LLG, C.()- CALCULATED BY )2.."N by c,-)2..p.-KI G-8DA lh 2. 1 • 9 2 1. DEVELOPMENT AREA (SQUARE FOOTAGE) Existing Proposed Total (Additions or Deletions) A. House and Garage (from Part 2.A.) 1.3 11 5"19 19b 9 (i B. Decking -- 3'10 3 "10 C. Driveway and Parking (Measured 100'along centerline) J 0 1 q - 10 -7 4 D. Patios and Walkways — 3 co 3 (o E. Tennis Court — — F. Pool and Decking -- — - G. Accessory Buildings (from Part B) H. Any other coverage — - -' TOTALS 1 3 1"7So 5 cl 3 3-7 LP Sr Maximum Development Area Allowed - MDA(from Worksheet#1) 2 7.3 7 2. FLOOR AREA (SQUARE FOOTAGE) (. 2S 3 0� Existing Proposed Total (Additions or Deletions) A. House and Garage a. 1st Floor 9 (p + A I eib 19 4 9 b. 2nd Floor — -- -- c. Attic and Basement -- -- ;.r d. Garage 3'7 I (3-i1 ) + 4 51 . 4 5 B. Accessory Buildings a. 1st Floor b. 2nd Floor c. Attic and Basement TOTALS 13v1 5/9 -j Si9 (o sF Maximum Floor Area Allowed-MFA (from Worksheet#1) 1701 SF /814) 1OWN USE ONLY CHECKED BYDA"i'b �j / c Se o�c s SQrnQ,u�-i� rhos °C1‘ C1t ror .66f- Revised 2/26/96 -e ✓