HomeMy WebLinkAbout3.5 TOWN OF LOS ALTOS HILLS September 9, 1998 Staff Report to the Planning Commission RE: SITE DEVELOPMENT PERMIT FOR A NEW RESIDENCE; LANDS OF BORNS, 25625 O'KEEFE LANE;FILE 104-98-ZP-SD. FROM: Shaunn O'Connor, Assistant Planner APPROVED BY: Curtis S. Williams, Planning Direct RECOMMENDATION That the Planning Commission: Approve the"requested Site Development Permit, subject to the attached conditions of approval, including condition #1 to require that the floor levels and roofline be better stepped with the slope. CODE REQUIREMENTS As required by Section 10-2.301 of the Site Development Ordinance, this application for a new residence has been forwarded to the Planning Commission for review and approval. Criteria for review from the Site Development Ordinance include grading, drainage, building siting, pathways, landscape screening and outdoor lighting. Zoning Code review encompasses compliance with floor and development area requirements, setbacks, height and parking. BACKGROUND The subject property for the proposed new residence is located near the terminus of O'Keefe Lane on the southern side (Assessor's Parcel No. 178-48-081, Lot 6 of Tract 8044, established in 1987). There are no subdivision conditions of approval for this site. The property extends from O'Keefe Lane to Highway 280. A Human Habitation setback line for noise exists along the southern boundary at approximately.90 feet from the Highway 280 right-of-way. A 10-foot wide public utilities easement exists along the interface of the cul- de-sac and a 10-foot wide pathway easement exists along the southern boundary of the property. The site is currently vacant. The lots on the northern side of O'Keefe Lane are developed and a residence is proposed for the adjacent site to the east. Planning Commission Lands of Borns September 9, 1998 Page 2 DISCUSSION Site Data: Gross Lot Area: 1.39 acres Net Lot Area: 1.39 acres Average Slope: 18.2 % Lot Unit Factor: 1.15 Floor Area and Development Area: Area Maximum Proposed Existing Increase Left Development 13,174 9,091 0 9,091 +4,083 Floor 6,428 6,098 0 6,098 +330 Site and Architecture The applicant is requesting approval of a site development permit for a new two story residence with two two-car attached garages. The proposed house will include 5,023 square feet of living area, and 1,075 square feet in the garage. Proposed exterior materials include cement plaster with smooth trowel and clay roof "mission" style tiles. There are no skylights proposed at this time (staff has included the standard skylight condition for future reference). Exterior colors will be reviewed for conformance with the Town's adopted color board, prior to the acceptance of plans for building plan check (see condition#4). The height of the residence will range from a maximum of 251/ feet for the second story, stepping down approximately to 16 feet for the first level and 14 at the front entry. The house will be setback 75 feet from O'Keefe Lane, 36 feet'on the east property line and 30 feet on the west property line. Story poles have been placed on the site for the Commission's review. The Design Guidelines recommends reserving some floor and development area for future projects. The proposed project would leave 330 square feet of floor area and 4,083 square feet of development area. Planning Commission Lands of Borns September 9, 1998 Page 3 Visibility and Height The site is located on a knoll, similar to the adjacent lot to the east, and is visible from neighbors on O'Keefe Lane, Highway 280 and Foothill College to the southwest. The topography of this lot has a gentle slope closer to O'Keefe Lane (about 210 feet) and an abrupt drop and increase in slope down to Highway 280. This lessens the visibility of the site from Highway 280 and from areas to the south and west. Although this lot is not as visible as the adjacent lot to the east, the Site Development Code section regarding construction on ridgelines and hilltops states the following: "single story buildings and height restrictions may be required on hilltops, ridgelines, and highly visible lots(Section 10-2.702.b1)" The applicant has proposed a partial two-story house with two two-car garages. The two- story section (left side) is at 251 feet in height. The applicant was directed to limit the size of the proposed second story, which now only comprises 810 square feet, or 15% of the square footage for the first level. The appearance of the two-story ridgeline, however, is carried across most of the structure to the right side, with a one foot step down to the single story portion. This roofline adds to the bulk and massing of the center of the structure from the front and rear sides of the residence. The rear of the residence is visible from Highway 280 and properties to the west. This side of the residence does have some recessed areas and some varied rooflines over the family room and master suite, but the bulkiness of the center portion remains noticeable. The Planning Commission may want to request that the applicant lower the ridgeline over the single story (center) portion of the structure by reducing attic space or ceiling heights (141/2 foot ceilings are shown) to minimize the bulk in the center portion, and then lower the two-story portion to further step the roofline. The applicant is proposing a clay "mission" style tile for the roof. Generally, "mission" style homes have red clay tile roofs and white or very light colored sides. Staff has concerns regarding the ability of the colors from the color board to match the clay "mission" style roof tiles and also the reflectivity value for red clay tiles. The applicant may want to take this into consideration before selecting the roof type. The Environmental Design Committee was concerned about landscaping for screening and roof and siding colors, due to the visibility of the site. Driveway &Parking The driveway on the site plan is shown to be 14 feet wide as recommended by the Fire Department. There are four parking spaces (two two-car garages) proposed which meets the Zoning Ordinance requirement for four on-site parking spaces. One garage faces O'Keefe Lane and the second faces the adjacent property to the east. The garages are in line with and opposite the proposed garages for 25665 O'Keefe (property to the east). There is a 60 foot separation between the proposed garages. Planning Cot riission Lands of Borns September 9, 1998 Page 4 Outdoor Lighting Structure lighting has been shown on sheet A7 of the plans along with cut sheets of proposed lighting. The lighting appears to be downshielded and is proposed as one light per exit. The front entry has two recessed can lights with a 100 watt maximum proposed. Staff has included a condition (#6) for any additional outdoor lighting (including landscaping), requiring that fixtures be downshielded and that all locations be approved by the Planning Department. Trees &Landscaping The project site is open grassland, lacking any trees that might help screen the proposed residence. Additional landscaping will be required to help screen the project and further break up the massing of the structure. Staff has included a condition (#2) that will require that a landscape plan be reviewed at a site development hearing once the house is framed. Any planting required for screening or erosion control will be required to be planted prior to final inspection. The Environmental Design & Protection Committee had concerns about the visibility of the site and asked that adequate screening be provided. Grading &Drainage The location for the proposed residence is on the most level area of the lot. Grading (1120 cubic yards of cut, 245 cubic yards of fill and 875 cubic yards of export) is proposed for the building pad. The proposed house does not meet the Town's grading policy in the southeast portion of the proposed house. The finished floors of the middle and lower levels of the house are proposed up to 4 to 5 feet above grade. The structure steps 2 feet from the bedroom area to the living area and 3 feet from the living area to the family room. Staff believes that the floor and roof levels for the house could be lowered 2 feet at least for the middle and lower levels to break up the roofline. This may increase cut and export, but would more closely comply with the grading policy (see condition #1) and would help lower the structure into this highly visible site. The new driveway would require minimal grading. The proposed garage would be located approximately 2 feet above natural grade. The Engineering Department has reviewed the plans and has recommended conditions of approval as specified in Attachment 1. The Engineering Department has suggested that the site drainage be designed as surface flow wherever possible to avoid a concentration of runoff. This has been included in condition #17. The Engineering Department will review and approve the final drainage plan prior to acceptance of plans for building plan check. Final "as-built" grading and drainage will be inspected by the Engineering Department, and any deficiencies will be required to be corrected prior to final inspection. Planning Commission Lands of Borns September 9, 1998 Page 5 Noise The Human Habitation Line was established for this subdivision to identify noise exposure levels within which habitable structures shall not be located. In addition, Edward Pack and Associates have reviewed the site plans and conducted a traffic noise exposure analysis for the site. The analysis was based on the Town's Noise Element standards for interior and exterior living areas, 45 dB and 60 dB respectively. The interior noise exposure for the first level will be up to 47 dB (2 dB above standards). The second story will be up to 49 dB, 4dB above Town standards. The consultants indicate that the highest point of noise exposure for exterior living area would be at the edge of the newly graded area at 62 dB during peak traffic hours (highest at morning commute). The heightened noise levels are due to the direct line-of-sight to sections of Highway 280. As one steps back toward the building pad and patio the noise level decreases to 60 dB (within Town standards). The report points out that the difference between a 60 dB environment and a 62 dB environment is generally indistinguishable. Edward Pack and Associates recommends that, if mitigation is desirable, a 6 foot sound wall (stucco or wood) be constructed above the berm for the full length of the site and connecting to the existing sound wall on the adjacent site to the east to lower the noise level for the edge of the newly graded area to 60 dB (see attachment 6). The Planning Commission may require that the sound wall be constructed and modify the conditions of approval. Interior mitigation will simply require that windows facing Highway 280 be of sound construction and adequately sealed around their perimeter to reduce noise. Geotechnical Review The Town geotechnical consultant, Cotton, Shires & Associates, has reviewed the plans and has visited the site. Approval of the project is subject to the conditions as specified in the Town Geologist's report of August 18, 1998 (see Attachment 3). Condition #9 includes the recommendations of the Town Geologist. Fire Department Review The Santa Clara County Fire Department has reviewed the plans and has approved the access to the residence. The property address will need to be placed so that it is clearly visible from O'Keefe Lane. A flow test on the closest hydrant revealed that the capacity is not adequate for a home of the proposed size and sections of the home are more than 150 feet from the centerline of the roadway. A residential fire sprinkler system or on-site fire hydrant will be required and must have approval prior to acceptance of building plans for plan check. Planning Commission Lands of Borns September 9, 1998 Page 6 Committee Review The Pathways Committee has requested that the applicant restore the II-B path along O'Keefe Lane. The Pathways Committee also invites the donation of a 10 foot pathway easement along the northern or eastern boundary of the property to connect the cul-de-sac to the pathway adjacent to Highway 280. The Environmental Design Committee requested that special attention be addressed to landscaping for screening and the color of exterior materials, as mentioned above. Staff is available to answer any questions that the Commission or the public may have. ATTACHMENTS 1. Recommended conditions of approval 2. Worksheet#2 3. Letter from Cotton, Shires &Associates,Inc. dated August 18, 1998 (three pages) 4. Santa Clara County Fire Department Comments dated June 12, 1998 (two pages) 5. Pathways Committee recommendation, dated June 22, 1998 (one page) 6. Sound wall Location map,Edward Pack and Associates, dated August 31, 1998 7. Plans cc: Ted Borns Borns Construction 845 Earl Avenue San Jose, CA 95126 Planning Comihission Lands of Borns September 9, 1998 Page 7 ATTACHMENT 1 RECOMMENDED CONDITIONS FOR SITE DEVELOPMENT PERMIT FOR A NEW RESIDENCE LANDS OF BORNS, 25625 O'KEEFE LANE File#105-98-ZP-SD-GD A. PLANNING DEPARTMENT: 1. " The applicant shall lower the floor levels and roof heights to better step the structure with the slope, with at least a two foot drop through the center portion of the roof, and an additional step at the two story roofline. Revised plans shall be submitted for review and approval by the Planning Department prior to acceptance of plans for building plan check. Any modifications to the approved plans shall be approved by the Planning Director or the Planning Commission, depending upon the scope of the changes. 2. Subsequent to final framing, a landscape screening and erosion control plan shall be reviewed at a Site Development Hearing. Particular attention shall be given to plantings which will be adequate to break up the view of the west side of the new residence from surrounding properties, streets and Highway 280 and maintaining privacy between neighbors. All landscaping required for screening purposes or for erosion control (as determined by the City Engineer) must be installed prior to final inspection, unless the Planning Director finds that unusual circumstances, such as weather or site conditions, require that planting be delayed. In those instances, a deposit of an amount equal to the cost of landscape materials and installation, to the satisfaction of the Planning Director,__shall be submitted to the Town. Landscaping shall in any event be installed not later than six months after final inspection, or the deposit will be forfeited. 3. A landscape maintenance deposit (or certificate of deposit), equal to the cost of materials and installation for all landscaping required for screening purposes or for erosion control (as determined by the City Engineer), but not to exceed $5,000, shall be posted prior to final inspection. An inspection of the landscape to ensure adequate establishment and maintenance shall be made two years after installation. The deposit will be released at that time if the plantings remain viable. 4. Paint colors shall be chosen by the applicant and approved by staff in conformance with the Town's adopted color board, and shall exhibit a Planning Commission Lands of Borns September 9, 1998 Page 8 light reflectivity value of 50 or less. Roofs shall use materials which have a light reflectivity value of 40 or less. White trim area should be minimized, particularly on large surfaces such as doors, columns, railings, and trellises. A color sample shall be submitted to the Planning Department for approval prior to acceptance of plans for building plan check. All applicable structures shall be painted in conformance with the approved color(s) prior to final inspection. 5. Fire retardant roofing (class A or B) is required for all new construction. 6. Outdoor lighting locations and specifications are approved as indicated on sheet A7. Any changes to outdoor lighting shall be approved by the Planning Department. Any additional outdoor lighting shall be reviewed with the landscape plan. Lighting fixtures shall generally be shielded and directed downward. Exceptions may be permitted in limited locations (entry, garage, etc.) or where the fixtures would not be visible from off site. Any security lighting shall be limited in number and directed away from clear view of neighbors, and shielding with shrouds or louvers is suggested. Lighting shall be low wattage, shall not encroach or reflect on adjacent properties, and the source of lighting should not be directly visible from off site. No lighting may be placed within the setbacks except for 2 driveway or entry lights, except where determined to be necessary for safety. 7. At the time of foundation inspection, the location, and elevation of the new residence and garages shall be certified in writing by a registered civil engineer or licensed land surveyor as being in/at the approved locations and elevations shown on the approved site development plan. At the time of framing, the height of the residence shall be similarly certified as being at the height shown on the approved site development plan. The hardscape and driveway locations shall also be certified at time of installation. 8. Skylights, if utilized, shall be designed and constructed to reduce emitted light. No lighting may be placed within skylight wells. 9. As recommended by Cotton, Shires & Associates in their report dated August 18, 1998, the applicant shall comply with the following: a. The applicant's geotechnical consultant should characterize anticipated peak and repeatable seismic ground motion in percent gravity for consideration by the project structural engineer. Previously recommended geotechnical design criteria should be updated as necessary. The current standard-of-care design for foundation piers within the Town (with similar soil conditions) is a minimum of four#5 Planning Commission Lands of Borns September 9, 1998 Page 9 vertical rebars. These standards should be considered by the consultant. The applicant's geotechnical consultant shall review and approve all geotechnical aspects of the of the development plans (i.e. Site preparation and grading, site drainage improvements and design parameters for foundations and driveway) to ensure that his recommendations have been properly incorporated. The results of the plan review should be summarized by the geotechnical consultant in a letter and submitted to the Town Geotechnical Consultant for review and approval prior to the • acceptance of plans for building plan check. b. The geotechnical consultant shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections should include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations prior to placement of steel and concrete.The consultant shall verify that new fill materials are properly keyed and benched into competent earth materials. The results of these inspections and the as-built conditions of the project shall be described by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to final inspection. For further details on the above requirements, please refer to the letter from Cotton, Shires &Associates dated August 18, 1998. B. ENGINEERING DEPARTMENT: 10. Any, and all, changes to the approved grading and drainage plan shall be submitted as revisions from the project engineer and shall first be approved by the Town Engineering Department. No grading shall take place during the grading moratorium between November 1 and April 1 except with prior approval form the Town Engineer. No grading shall take place within ten (10) feet of any property line except to allow construction of the driveway access. 11. All public utility services serving this property shall be placed underground. 12. An erosion and sediment control plan shall be submitted for review and approval by the Engineering Department prior to acceptance of plans for building plan check. The contractor and the property owner shall comply Planning Commission Lands of Borns September 9, 1998 Page 10 with all appropriate requirements of the Town's NPDES permit relative to grading and erosion/sediment control. The first 100 feet of the driveway shall be rocked during construction and all cut and fill slopes shall be protected from erosion. All areas on the site that have the native soil disturbed shall be protected for erosion control during the rainy season and shall be replanted prior to final inspection. 13. Two copies of a grading and construction operation plan shall be submitted by the property owner for review and approval by the City Engineer and Planning Director prior to acceptance of plans for building plan check. The grading/construction plan shall address truck traffic issues regarding dust, noise, and vehicular and pedestrian traffic safety on •O'Keefe Lane and surrounding roadways; storage of construction materials; placement of sanitary facilities; parking for construction vehicles; and parking for construction personnel. In particular, the plan should address how construction personnel vehicles will be parked so as to leave the roadway clear. A debris box (trash dumpster) shall be placed on site for collection of construction debris. Arrangements must be made with the Los Altos Garbage Company for the debris box, since they have a franchise with the Town and no other hauler is allowed within the Town limits. 14. The property owner shall inform the Town of any damage and shall repair any damage caused by the construction of the project to pathways, private driveways, and public and private roadways, prior to final inspection and shall provide the Town with photographs of the existing conditions of the roadways and pathways prior to acceptance of plans for building plan check. 15. The driveway shall be required to be fully constructed and to be roughened where the pathway intersects, to the satisfaction of the City Engineer, prior to final inspection. 16. The property owner shall be required to connect to the public sanitary sewer prior to final inspection. A copy of a permit from the City of Los Altos shall be required to be submitted to the Town prior to acceptance of plans for building plan check. 17. The site drainage associated with the proposed development must be designed as surface flow wherever possible to avoid concentration of the runoff. The proposed drainage shall be designed to maintain the existing flow patterns. Final drainage and grading shall be inspected by the Engineering Department and any deficiencies corrected-to the satisfaction of the Engineering Department prior to final inspection. A letter shall be submitted from the project engineer stating that the drainage Planning Commission Lands of Borns September 9, 1998 Page 11 improvements were installed as shown on the approved plans and in accordance with their recommendations prior to final inspection. 18. The applicant shall restore the MB pathway along O'Keefe Lane, to the satisfaction of the Engineering Department,prior to final inspection. C. FIRE DEPARTMENT 19. The driveway shall be a minimum of 14 feet wide (as shown on site development plan) with an unobstructed vertical clearance 131/2 feet, shall have an all weather surface that is designed and maintained to support the imposed loads of fire apparatus (40,000 pounds) and the gradient shall not • exceed 15%. 20. An automatic residential fire sprinkler system approved by the Santa Clara County Fire Department shall be included in the new residence. Plans prepared by a sprinkler contractor shall be submitted and approved by the Fire Department,prior to acceptance of plans for building plan check, and the sprinklers shall be inspected and approved by the Fire Department, prior to final inspection. The applicant may propose alternate means of achieving an acceptable water supply in lieu of fire sprinklers, subject to the approval of the Fire Department. 21. The property address shall be placed on the property so that it is clearly visible and legible from O'Keefe Lane. The address numbers shall be a minimum of four inches high and shall contrast with the background color. Upon completion of the construction, a final inspection shall be required to be set with the Planning and Engineering Departments two weeks prior to final building inspection approval. CONDITION NUMBERS, 1, 4, 6, 9a, 12, 13, 14, 16, 17 and 20 SHALL BE COMPLETED AND SIGNED OFF BY THE PLANNING DIRECTOR AND THE CITY ENGINEER PRIOR TO ACCEPTANCE OF CONSTRUCTION PLANS FOR PLAN CHECK BY THE BUILDING DEPARTMENT. Properties must pay School District ( Los Altos or Palo Alto) fees before receiving their building permit from Los Altos Hills. The applicant must take a copy of required fee payment forms that have been completed by the Town to both the elementary and high school district offices, pay the appropriate fees and provide the Town with a copy of their receipts. NOTE: The Site Development permit is valid for one year from the approval date (until September 9, 1999). All required building permits must be obtained within that year and Planning Commission Lands of Borns September 9, 1998 Page 12 work on items not requiring a building permit shall be commenced within one year and completed within two years. 88 12:54 408-615-4004 GIULIANI & KULL INC PAGE 02 TOWN OF LOS ALTOS HILLS ATTACHMENT 2. 26379 Fremont Road • Los Altos Hills,California 94022 • (415)941-7222 • FAX(415)941-3160 PLANNING DEP WORKSHEET #2 EXISTING AND PROPOSED DEVELOPMENT AREA AND FLOOR AREA • TURN IIS WITH YOUR APPLICATION • PROPERTY OWNER'S NAME aoRAS PROPERTY ADDRESS 0 IC CALCULATED BY CE -lk. 'DATE 8/ j q g L DEVELOPMENT AREA (SQUARE FOOTAGE) Existing Proposed Total (Additions or Deletions) A. House and Garage (from Part B) &o B. Decking I'Ffo C Driveway and Parking (Measured 100' along centerline) 181-1O D. Patios and Walkways &4-0 E. Tennis Court - 33 F. Pool and Decking • G. Accessory Buildings (from Part B) • }L Any other coverage . • TOTALS 9o/ / Maximum Development Area Allowed - MDA (from Worksheet #1) /3, 7 '4 . FLOOR AREA (SQUARE FOOTAGE • Existing Proposed Total (Additions or Deletions) A. House and Garage a. 1st Floor 4-_ 3 b. 2nd Floor gr o c. Attic and Basements ' d. Garage • l o .7 5 B. Accessory Buildings a. 1st Floor • b. 2nd Floor c. Attic and Basement. TOTALS o S Maximum Floor Area Allowed - MFA (from Worksheet #1) 4-42-5' TOWN USE ONLY CHECKED 13Y DATE wised 12/09/93 LRL: MAC HD/ORIGINALS/PLANNING/Worksheet e2 ATT CHMENT. . • COTTON,-SHIRES & ASSOCIATES, INC. AUG CONSULTING ENGINEERS AND GEOLOGISTS August 18, 19•98 L3148 • TO: Susan Stevenson Planner TOWN OF LOS ALTOS HILLS 26379 Fremont Road Los Altos Hills, California 94022 SUBJECT: Preliminary Geologic and Geotechnical Review RE: Lands of Borns Construction-New Residence File #105-98-ZP-SD-GD 25625 O'Keefe Lane At your request, we have completed a preliminary geologic and geotechnical review of the subject property using: • Geotechnical investigation on 9-Lot residential development for Medhi Mohammedian, prepared by Terrasearch Inc., dated July 18, 1986. • Architectural Plans (6 sheets) prepared by Stotler Design Group, dated August 3, 1998, and • Site Development Plan prepared by Guiliani & Kull Inc., dated July 23, 1998. In addition, we have reviewed pertinent documents from our office files and completed a site reconnaissance. DISCUSSION • Our review of the referenced documents indicates that the applicant is proposing to construct a new two-story residence on the subject property. Our review addresses the geotechnical feasibility of the project development plan and the adequacy of submitted geotechnical documentation. Proposed project grading includes 1120 cubic yards of cut, 245 cubic yards of native fill, and 875 cubic yards of imported fill. The proposed residence would be accessed by a driveway extending from the western terminus of O'Keefe Lane. SITE CONDITIONS The lot is characterized by a broad southward draining swale, with an artificial fill sound barrier berm across the southern property line (adjacent to Interstate 280 freeway). 1orthern California Office Southern California Office 30 Village Lane 5245 Avenida Encinas • Suite A .os Gatos,CA 95030-7218 Carlsbad,CA 92008-4374 408)354-5542 • Fax(408)354-1852 (760)931-2700 • Fax(760)931-1020 -mail: losg@csageo.com csageo.com e-mail:carl@csageo.com .ATTACHMENT Susan Stevenson August 18, 1998 0;00/00/- Page 2 - - L3148 A 12-inch culvert is in the axis of the swale to allow drainage through the berm. The slopes on either side of the swale are moderately steep (18 percent inclination). The slopes on the artificial fill material of the sound barrier berm are very steep (58 percent inclination). The Town Geologic Map indicates that the house site is underlain, at depth, by bedrock materials of the Santa Clara Formation (conglomerate, sandstone, siltstone, and claystone). The bedrock is in turn overlain by clayey sand to silty clay (potentially expansive soil, colluvium, and artificial fill). Although no direct exposure of bedrock was observed on the subject property, the log of the borehole cuttings by Terrasearch suggest conglomerate is found at depths below 6 feet. The mapped traces of the potentially active Monta Vista fault and the active San Andreas fault are 800 feet northeast and 4 miles southwest, respectively, from the subject property. CONCLUSIONS AND RECOMMENDED ACTION The proposed development is constrained by potential soil creep, expansive soils, and the susceptibility to strong seismic ground shaking. The basic site development plan appears geotechnically feasible and we have no geotechnical objections to the proposed development plan. Prior to issuance of permits for construction, the Project Geotechnical Consultant should update the 1986 geotechnical design criteria, as required to be consistent with the currently accepted standards of practice, and as needed to address proposed site improvements. Consequently, we recommend that the following conditions be completed prior to issuance of construction permits: 1. Geotechnical Plan Review and Supplemental Geotechnical Investigation - The applicant's geotechnical consultant should characterize anticipated peak and repeatable seismic ground motion in percent gravity for consideration by the project structural engineer. Previously recommended geotechnical design criteria should be updated as necessary. The current standard-of- care design for foundation piers within the Town with similar soil conditions is a minimum 16-inch diameter pier reinforced with a minimum of four #5 vertical rebars. These standards should be considered by the consultant. The applicant's geotechnical consultant shall review and approve all__geotechnical aspects of the development plans (i.e., site preparation and grading, site drainage improvements and design parameters for the foundation, and retaining walls) to ensure that their recommendations have been properly incorporated. Only one exploratory bore hole was drilled on the subject property for subsurface investigation. The consultant should consider whether additional boreholes are needed to adequately characterize the conditions as a basis of recommended parameters for foundations, retaining walls, and other structures. COTTON, SHIRES& ASSOCIATES, INC. /c :P 11r�'►�I'1iMCIV 1 J Susan Stevenson August 18, 1998 • Page 3 • L3148 The results of the supplemental evaluations plan review should be summarized by the Project Geotechnical Consultant in a letter and submitted to the Town Geotechnical Consultant for review and approval prior to issuance of building permits. 2. Geotechnical Field Inspection -The geotechnical consultant shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections should include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations and retaining walls prior to the placement of steel and concrete. The consultant shall verify that new fill materials, if any, are properly compacted, keyed and benched where appropriate into competent earth materials. The results of these inspections and the as-built conditions of the project shall be described by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to final (as- built) project approval. This review has been performed to provide technical advice to assist the Town in its discretionary permit decisions. Our services have been limited to review of the documents previously identified, and a visual review of the property. Our opinions and conclusions are made in accordance with generally accepted principles and practices of the geotechnical profession. This warranty is in lieu of all other warranties, either expressed or implied. Respectfully submitted, COTTON, SHIRES AND ASSOCIATES, INC. TOWN GEOTECHNICAL CONSULTANT Ted Sayre Supervising Engineering Geologist CEG 1795 tkic-k0 Patrick O. Shires Principal Geo technical Engineer GE 770 POS:TS:cw COTTON, SHIRES & ASSOCIATES, INC. ATTACHMENT Li t4'GLARA, OD FIRE DEPARTMENT c A SANTA CLARA COUNTY CONTROLNOINBER"","" .,�FIR,El?� 2 14700 Winchester Blvd., Los Gatos. CA 95032-1818 BLDG PERMIT NyW1 1•C��JQ 8 (408) 378-4010 (phone) • (408) 378-9342 (fax) COURTESY 6 SERVICE PLAN REVIEWIlyrIER RR is FILE NUMBER 105-98-ZP-S DEVELOPMENT REVIEW COMMENTS CODE/SEC. SHEET NO. REQUIREMENT Review of proposed new single family residence. The planner for this project is Ms. Suzanne Davis. 1 Review of this Developmental proposal is limited to acceptability of site access and water supply as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work the applicant shall apply to the Building Department for applicable construction permits. UFC 2 Required Fire Flow: Required fire flow for this project is 2,000 GPM at 20 psi Appendix III-A residual pressure. The required fire flow is not available from area water mains and fire hydrant(s) which are spaced at the required spacing. UFC 3 Required Fire Flow Option (Single Family Dwellings): Provide required fire 903.2 flow from fire hydrants spaced at a maximum of 500 feet OR Provide an approved fire sprinkler system throughout all portions of the building. The fire sprinkler system shall conform to National Fire Protection Association Standard #13D, 1994 Edition, and local ordinance requirements. 2 4 Required Access to Water Supply (Hydrants): Portions of the structure(s) are 90 903.2 greater than 150 feet of travel distance from the centerline of the roadway containing public fire hydrants. Provide an on-site fire hydrant OR provide an approved residential fire sprinkler system throughout all portions of the building. DISTRICT PLANS SPECS NEW RMDL AS OCCUPANCY CONST.TYPE PERMITTEE - DATE PAGE LAH 0 0 0 0 0 STOTLER DESIGN GROUP 06/10/98 1 OF 2 SECJFLOOR AREA LOAD DESCRIPTION BY Residential Development Hokanson,Wayne NAME OF PROJECT LOCATION LANDS OF BORNS 25625 Okeefe Ln A California Fire Protection District serving Santa Clara County and the communities of Campbell. Cupertino. Los Altos. Los Altos l lilts, los Gatos. Monte Sereno. Morgan Hill. and Saratoga i,ARA , . ATTACHMENT - yp' ;' c4. °ems FIRE DEPARTMENT �Y kit. - s.�t ' SANTA CLAIM COUNTY CONTROL NUMBER prey t�..5ra `,•.A•�F�..,J'ti { ',A,t`,7e 14700 Winchester Blvd., Los Gatos, CA 95032-1818 LbG P R it NUMeF COURTESY B SERVICE (•08) 370-4010 (phone) • (408) 378-9342 (fax) 1 ,J. �rlJ –_ — P<1Nl`f�EVIENFNUIGIBER8 9 8— 1483 RAH OF ii6 ObliaU 1 5 98-ZP-S DEVELOPMENT REVIEW COMMENTS CODE/SEC. SHEET NO. REQUIREMENT IFC 5 Premises Identification: Approved numbers or addresses shall be placed on all 901.4.4 new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Numbers shall contrast with their background and be a minimum of four inches in height. Prior to building permit being issued, applicant shall identify to this department their intention to install fire sprinklers in the residence. The required fire flow will need to be accomplished using two hydrants otherwise. Contact Wayne Hokanson at 408-378-4010 for assistance if necessary. DISTRICT PLANS SPECS NEW RMDL AS OCCUPANCY CONST.TYPE PERMITTEE DATE PAGE LAH 0 0 0 0 0 STOTLER DESIGN GROUP 06/10/98 2 OF 2 SECJFLOOR AREA LOAD DESCRIPTION BY Residential Development Hokanson, Wayne NAME OF PROJECT LOCATION LANDS OF BORNS 25625 Okeefe Ln A California Fire Protection District serving SniOn Clara County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Chios, Monte Sereno, Morgan Hill, and Saratoga . ATTACHMENT 5. hway Minutes e 22, 1998 e Two st, Eric Clow, submitted a sample of another survey regarding the residents ' Lings towards the pathway system in the town . The committee agreed it was necessary to do another survey. Z5 Edgerton Road; Lands of Cheek: No request . 51 Fremont Road; Lands of Blair : Construct a II-B path along Fremont but arated from the pavement by at least 5 feet . 40 La Paloma Road; Lands of Owen: Construct a II-B path along La Paloma • 25 O' Keefe Lane; Lands of Borns Construction: Restore II-B path along =efe Lane . Invite donation of a 10 foot pathway easement along either the :hern or eastern boundary of the property, to connect the cul-de-sac to the away next to the freeway - ;5 O ' Keefe Lane; Lands of Euro Development : Restore II-B path along O' Keefe Invite donation of a 10 foot easement along the western boundary of the )erty to connect the cul-de-sac to the pathway next to the freeway 5 Samuel Lane; Lands of Nuveen Construction: No request i9 Samuel Lane; Lands of Nuveen Construction: Restore II-B path along .ssima Road )0 Suuuuerhill Road; Lands of Kamanger: Construct II-B path, separated 5 feet 1 Summerhill ; grant easement if needed 10 Wildflower Lane; Lands of Danaher: Grant an easement if needed and ;truct a II-B path along Wildflower Lane iittee supported Les Earnest ' s. attendance at the Pro Bike/Pro Walk erence, September 8-11 fitted by Sylvia Jensen __`' ``. 4.7 THJS SURVEY IS BASED ON TOWN or• LOS ALTOS HILLS DAMN (LAH 13).4 15 ) e2.-Fl.- , ..-.• '-4- . '''..•":'14% .'.:-.. '....ics'°I ''' 1 •' or. ....3...:::.:.--.4: vorey.--.-,,,s77, -.;;,..:......4.., ..----7- A p.4 74::•:::::': 1 :• - S. . Gm,NI"SC°= 7,7; . L. •••,-.40.10 -kg ... %-. • , • .4.,,O.... ._..:.*** ›.., /.... ft,.. • 1 ._ iillgi....... ? ., 1 k• • \ . • . . . : •:\ .../. ....„.. • Top of. barrier shall remain constant in refen3rioe to the '. . \. _____ • 1 •. -1........„...Y.. .,0 i . • .- 1 I. • . FIGURE 1 ./---; •• ---.,........ � ` __-_ -__-_— • ° ~— � _ _-